Model ER-6/R (Remote) Digital Resettable Totalizer
ABOUT THIS MANUAL
This manual explains how to install, operate and maintain the
Badger Meter® Model ER-6/R electronic register.
The troubleshooting section lists the most common problems
that may be encountered, their most likely cause and the
recommended solutions.
PRODUCT DESCRIPTION
The ER-6 register is a remote totalizer designed for use with all
Badger Meter product lines.
The supertwist LCD display with 8 digits for totalizing, provides easy
viewing at a glance. For conditions where ambient light is poor, the
display can be backlit by connecting an external DC (10…28V DC)
power supply. A single unit can accept NPN or dry contact inputs for
low or high speed applications.
The ER-6/R register is powered by one replaceable 3V Lithium
battery. You can install a new battery before removing the old one,
thereby retaining count total. A low battery indicator appears on
the screen to provide a warning a couple of weeks before the end of
battery life. If two batteries are used simultaneously, the individual
expected life doubles to 10 years.
INSTALLATION
Panel Installation
Place the unit in the panel through a 33 mm × 68 mm cutout. Slide
the included gasket over the rear of the unit, then slide the panel
mount bracket into place so that the 4 tabs catch in the grooves on
the top and the bottom of the unit (the bracket should be oriented
so that the tabs are on the side nearest the panel). Use the provided
panel mount screws to tighten the bracket until there is a secure
seal against the gasket. Do not over tighten.
Battery Installation/Replacement
The ER-6/R register is shipped with one battery, which is not
installed. Remove the battery cover by pushing inward and down.
Install the battery in one of the two slots. The unit runs on a single
battery, and the second slot is provided to allow for installing a
new battery before removing the old one, retaining count total.
The unit can also be run on two batteries to extend the battery life
to 10 years. Once the battery is in place, the unit goes into a selftest mode, and all the segments on the LCD display illuminate. To
exit the self-test mode, press RST, which then displays the model
number (0). Press RST again to ready the unit for operation.
REG-UM-02417-EN-04 (May 2017)
Figure 1: Panel installation
Figure 2: Battery installation
User Manual

Wiring Instructions
WIRING INSTRUCTIONS
Wiring Terminals
3
2
1
Figure 3: Wiring terminals
Terminal Function Operation
1 DC common —
2 Count input —
3 — Not used
4 Remote reset Resets count value when switched to common.
5 Front panel reset enable Enables count value to be reset by using the front panel Reset key.
6 — Not used
7 — Not used
8 DC supply input 10…28V DC for backlighting.
Table 1: Wiring terminals
The ER-6/R register is shipped with one lead wire attached to terminal 5. To enable front panel Reset, attach the other end of the lead to
terminal 1.
6
7
8
Transmitter Connections
For connecting to Badger Meter transmitters, refer to the literature for your specific transmitter and to Table 2 below. The Connections
column refers to the wires on the transmitter. The numbers in parenthesis refer to the terminal numbers on the ER-6/R register. Connect the
wire coming from the transmitter to the corresponding terminal number for the ER-Series Remote models.
Transmitter Connections
MS-E1 Black (1) Red (2)
MS-E5 Black (1) Red (2)
PFT-1E Terminal 6 (1) Terminal 5 (2)
PFT-4E Terminal 6 (1) Terminal 5 (2)
PM-5 Black (1) Red (2)
Table 2: Transmitter connections
OPERATION
34675890
Figure 3: Total display
Total Display
Total Display indicates the present count value, which is equal to the number of pulses received since the last reset.
Reset Key
While the Total Value displays, press RST to reset the value to zero.
Page 2 May 2017REG-UM-02417-EN-04

TROUBLESHOOTING
Problem Possible Causes Remedies
Screen is blank Battery is dead. Replace battery.
Will not count 1. Broken or defective wiring.
1. Check wiring.
TROUBLESHOOTING
2. Improperly connected.
3. Transmitter defective.
Cannot reset from front panel Reset enable is active. Check connection between terminals 1 and 5.
Erroneous readings Defective transmitter. Repair or replace transmitter.
Table 4: Troubleshooting
For further assistance, call our Technical Support Staff at 1-800-876-3837.
2. Check connections.
3. Repair or replace transmitter.
SPECIFICATIONS
Count Input (Terminal 2)
Type NPN signal, contact closure
Count speed
Minimum pulse
Maximum input 28V DC
Impedance 1 Meg to battery
Front Panel Reset Enable (Terminal 5)
Maximum input 28V DC
Remote Reset Input (Terminal 4)
Frequency response 30 Hz (50% duty cycle)
Maximum input 28V DC
Operating Temperature
Indicator 32…140° F (0…60° C)
NPN, 280 Hz maximum,
Contact, 95 Hz maximum
Logic Low < 1.0V DC, High > 2.0V DC
NPN,1.78 μs, Contact, 5 ms
width
Type NPN signal, contact closure; level sensitive
Type NPN Signal, Contact closure; edge sensitive
Power Source
Type Single 3V Lithium battery
Replacement part # 62576-001
Battery life
expectancy
Low power indicator
Display
Number 8 digits
Height 12 mm (0.472 in.)
Backlighting
Physical
Dimensions
Mounting
Connections Up to 8 screw terminals
Weight Approximately 13 ounces
5 years
“Low Bat” flashes on display approx. 2
weeks prior to end of battery life
Supertwist LCD for use with or
Type
without backlighting
Green Illumination over whole viewable
area with a 10…28V DC supply
(Terminal 8)
36 mm × 72 mm, 38 mm deep
(1.417 in. × 2.835 in., 1.496 in. deep)
Panel mount (mounting bracket supplied)
33 mm × 68 mm (+ 0.3 mm) panel cutout
1.299 in. × 2.677 in., (+ 0.012 in.)
panel cutout
Page 3 May 2017 REG-UM-02417-EN-04

Industrial Registers, Model ER-6/R (Remote) Digital Resettable Totalizer
Control. Manage. Optimize.
Trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves
the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2017 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Eastern Europe Branch Oce (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412
Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11 Legacy Document Number: IOM-071 53400-071