Badger Meter ER-420-AC, ER-420-DC, ER-420-LP Data sheet

Industrial Registers
Models ER-420-AC, ER-420-DC & ER-420-LP Totalizer and Rate of Flow Indicator with 4-20 mA Output Signal
DESCRIPTION
The Badger Meter® Model ER-420 series digital register is especially designed for computing and displaying total and rate of flow in fluid flow applications. The units are suitable to handle any volumetric flow meter with a pulse output.
OPERATION
Model ER-420 is fully menu-driven with understandable text. This register continues counting during programming.
The analog output with 10 bits resolution has programmable set points proportional to the flow rate for both 4 mA and 20 mA output.
A scaled pulse mirroring the count on the display is generated for use by external instruments. The maximum frequency is 20 Hz while the pulse width can be adjusted to suit both electromechanical and electronic counters.
OPERATOR FUNCTIONS
The operator has three functions available:
• TOTAL and flow rate are displayed.
• TOTAL can be reset by pressing CLEAR key twice.
• After pressing SELECT, accumulated TOTAL will be displayed (cannot be reset).
FEATURES
• Instantaneously displays rate of flow, total and accumulated total
• Scalable 4…20 mA analog output proportional to rate of flow
• Scalable pulse output
• Available in Loop Powered, AC or DC powered versions
REG-DS-00743-EN-09 (December 2015)
Product Data Sheet
Industrial Registers, Models ER-420-AC, ER-420-DC & ER-420-LP
SPECIFICATIONS
Display
Type High intensity reflective numeric and alphanumeric LCD, UV-resistant
Digits Seven 17 mm (0.67 in.) and eleven 8 mm (0.31 in.). Various symbols and measuring units
Refresh rate User definable: 8 to 30/sec
Enclosures
General Control Keys GRP (glassfiber-reinforced polyamide) enclosure with polycarbonate window, silicone and
EPDM gaskets UV-stabilized and flame retardant material Three industrial micro-switch keys. UV-stabilized silicone keypad
Field/wall-mount enclosures Classification Drilling
Operating Temperature
Operational –30…80° C (–22…178° F)
Power Supply
ER-420-DC 24V AC / DC + 10%. Power consumption maximum is 0.5 Watt
ER-420-AC 115…230V AC + 10%. Power consumption maximum is 0.5 Watt
ER-420-LP Output loop powered: 8…30V DC. Power consumption maximum is 0.5 Watt
Models DC/AC The total consumption of the sensors, backlight and outputs may not exceed 400 mA @ 24V
Sensor Excitation
Dimensions: 130 x 120 x 75 mm (5.10 in. x 4.72 in. x 2.95 in.) LxHxD. IP67 / NEMA4X Three 3/4 in. holes
ER-420-LP 3.2V DC for pulse signals.
OTE:N This is not a real sensor supply. It is suitable only for pulse sensors—like reed switches—with
a very low power consumption.
ER-420 AC/DC 3.2, 8.2, 12 and 24V DC. Maximum is 400 mA @ 24V DC
Terminal Connections
Type Removable plug-in terminal strip. Wire maximum is 1.5 mm2 and 2.5 mm
Data Protection
Type EEPROM backup of all settings, backup of running totals every minute
Data retention is at least 10 years
Passcode Configuration settings can be passcode protected
Environment
Electromagnetic compatibility Compliant ref: EN 61326 (1997), EN 61010-1 (1993)
Inputs
Flowmeter
Type P NPN/PNP, open collector, reed switch, active pulse signals 8…12 and 24V
Frequency Minimum 0 Hz, maximum 7 kHz for total and flow rate
Maximum frequency depends on signal type and internal low-pass filter Example: Reed switch with low-pass filter: maximum frequency is 120 Hz
K-Factor 0.000010…9,999,999 with variable decimal position
Low-pass filter Available for all pulse signals