Model EC-A
GENERAL
Badger Meter's Electric Contacting Register, Model EC-A, is
used on Disc and Turbo meters to provide an electric pulse
output for a given quantity of liquid metered. In a typical application, the pulses would be transmitted to a chemical feed
pump for boiler makeup water or for cooling towers.
The top portion of the EC-A unit consists of a register with
a nonresettable totalizer. This register is mounted on top of
the contactor section which consists of a gear train assembly,
cam-operated switch and appropriate change gears.
The contact rates of the EC-A accessory can be adjusted in
the field with the use of change gears and/or different gear
train assemblies.
The register can be indicating one unit of measure while the
contact rate is supplied in a different unit of measure. For
example, gallons and cubic feet.
Electric Contacting Register
Technical
Brief
OPERATION
Water or other liquid flowing through the meter will cause the
cam in the contactor section to rotate. The cam operates a
single-pole, double-throw (SPDT) switch. When connected
to a suitable power supply, the EC-A register will provide a
pulse output corresponding to a predetermined quantity of
liquid. The pulse rates range is from 10 gallons to 10,000 gallons per contact, depending on the meter size. If desired, the
pulses can be used to actuate a relay which, in turn, would
operate other equipment.
WIRING DIAGRAM
EC-A on 3" Turbo Meter
FEATURES
Unit can be calibrated in field.•
Non-ressettable totalizer.•
Scaled pulse output.•
SWITCH
Single-pole, double-throw . . . N.O. or N.C. connections . . .
Ratings of 10 amps and 1/4 h.p., 125 or 250 volts AC, 1/2
amp, 125 volts DC, 1/4 amp, 250 volts DC.
ITB-100-02
BadgerMeter,Inc.
Part No. 53406-100
3-09
EC-A REGISTER MODELS
1/
1
" M120 RCDL
2
Disc
Meter Size
Test
Circle*
5/8" M25 RCDL
Disc
3/4", 1"
M35, M40, M70
RCDL Disc
10 Gallons 10 Gallons 100 Gallons 100 Gallons 1000 Gallons 1000 Gallons
1 Cubic Ft. 1 Cubic Ft. 10 Cubic Ft. 10 Cubic Ft. 100 Cubic Ft. 100 Cubic Ft.
Units of
Measure
100 Pounds 100 Pounds 1000 Pounds 1000 Pounds 10,000 Pounds 10,000 Pounds
10 Liters 100 Liters 100 Liters 1 M3 1 M3 10 M
Range of
Contacts
10 Gallons/Contact to
500 Gallons/Contact
50 Gallons/Contact to
5000 Gallons/Contact
NOTE: Units per contact are expressed in gallons. Other units of equivalent volumes are available.
*Meter Test Circle equals one complete revolution of the sweep pointer.
c
c
2" & 3" Turbo &
2" M170 RCDL
Disc
4" Turbo
100 Gallons/Contact to
10,000 Gallons/Contact
6" Turbo
3
RCDL M40
Disc Meter Size M25 M35 & 70
Dimen. (Inches)
A 12
B 7
C 6.98 7.58 8.18
1/
14 16
4
1/
9 10
2
3/
4
D 1.7 1.7 2.3
Please see our website at
www.badgermeter.com
for specific contacts.
RCDL
Disc Meter Size M120 M170
Dimen. (Inches)
A 18.37 22.87
B 12.62 15.
1/
C 8.58 9.08
D 2.4 2.9
.
Due to continuous research, product improvements and enhancements, Badger
Meter reserves the right to change product or system specifications without notice,
except to the extent an outstanding bid obligation exists.
Turbo Meter Size 2 3 4 6
Dimen. (Inches)
A 10 12 14 18
4
B 11
1/
11
16
C 6 7
Appr. Ship. Wt.
(Lbs.) 30 40 85 125
BadgerMeter, Inc.
P.O. Box 245036, Milwaukee, WI 53224-9536
Telephone: (414) 355-0400 / (800) 456-5023
13/
1/
14
16
16
1/
4
9 11
2
3/
4
Fax: (414) 355-7499 / (866) 613-9305
Copyright © Badger Meter, Inc. 2009. All rights reserved.