AZ Instrument NICELOG Users Manual

Instruction Manual
Bluetooth
Data Logger
Introduction
Product Description
LED indicator:
Low/High: Red LED blinks every 5 seconds when the measuring set limit value is exceeded during record. OK: When the logging function is started, the green LED blinks once every 5 seconds when there is no alarm occurs. NTC thermistor for temperature measuring and capacitive humidity sensor for humidity measuring.
External probe socket in models with external probe port
LCD (Liquid Crystal Display).
a. Measured temperature or humidity or pressure. LCD updates and interexchange every 5 seconds. b. REC flashes every second when logger is in logging mode. While logger is programmed with start delay, REC displays but doesnt flash during the standby status. c. T1 is air temperature, T2 is external probe temperature d. H or L displays when measuring set limit value is exceed. e. MX or MI display when checking MAX or MIN value from logged data. f. Low battery icon flashes on display every second when battery level is too low to accurately measure and log data. g.The real time value is broadcasted to APP every 5 seconds. Battery cover, operated by 1 pc CR2 battery. Use coin and follow up the direction indicator to open and close the cover. While inserting the
battery, follow up the +/- sign on PCB. START/STOP (ON/OFF) key:
After installing the batteries, press key to power on the logger. LCD displays for 2 seconds. Press again to turn off. After set by App, if the logger is programmed as Key start, press the Start/Stop button for 5 seconds to start logging. if the logger is programmed as Key stop”, press the Start/Stop button again for 5 seconds to stop logging. In the logging mode, short press key wont power off the logger. MAX/MIN key: Press key to check the MAX or MIN data of all logged data. Magnet mounting 3 magnets on the rear side to fix the logger on ventilation shaft or iron rack. Hanger
Operation
NOTE:
1. Smart phone with Bluetooth is required. iOS above 10 or Android above 5.0 are also a must to run programming APP smoothly.
2. Programming APP can be download for free. Please search for “ Nice Logger in App Store (iOS) or in Play Store (Android) .
Step1 Configuring the data logger
It is possible to make configuration changes at anytime before the logging function is started. Once the logger is started, configuration changes cannot be made unless stopping the logging first. If the logger is locked with a Password, the Password is required to make configuration changes.
- Press ON/OFF to power on the logger.
- Turn ON the Bluetooth of smart device & APP. APP will auto scan available and recognized loggers nearby.3 loggers can be displayed in one page. Click gray dot to switch to other page. Press the desired logger to link for further programming.
- User programmable parameters are grouped as two sections in APP. One is Configure and the other one is Logger ID.
Configure
In Configure, you can program logger with desired way to start/stop logging and things about alarm. Sampling rate Select the sampling interval you need from 10 seconds to 2 hours, the increment of the sampling interval is 10 seconds, so the sampling
interval should be 10 sec. 20sec. 30sec. and so on Start & Stop Mode Select how you would like to Start and Stop the logger. There are 2 choices for start logging and 4 choices for stop logging, no matter which method is picked up, user can always stop logging from APP. Start choices: A.By key start: Means pressing key to start logging after set by App B.By on time start: Means user program a desire time point to start logging after set by App. Stop choices: A. Memory loop till key stop: Means pressing key to stop logging. When the memory is full before user pressing stop key, the new data will overwrite the old one till user pressing key to end. B. Memory full or key stop: Means pressing key to stop logging. When the memory is full, the logging will stop even user didnt press key to stop. C. Memory loop till Date/Time: Means user program a desire time point to stop logging. When the memory is full but not yet reaching stop time, the new data will overwrite the old one
till time is up. D. Memory full or on Date/Time: Means user program a desire time point to stop logging. Before reaching the stop time, if the memory is full, the logging stop as well. Start delay Select the start delay from 0 min to 24 hours. For example: If the delay is 10 minutes, and the sampling rate is 20 minutes, the real time to log the first temperature measurement is 10 minutes after the START button is pressed. All measurements after the first measurement will be at a 20 minute (or selected) interval. The increment of the start delay is 10 minutes, so the start delay should be 10 min. 20 min. 30 min. and so on Alarm types Regardless of the Alarm Type, if the red LED is triggered, it won’t stop even the reading return to normal range or logging is stopped. To stop red alarm LED, logging must be stopped and then connect logger to APP to read out data or re-config. There are two types of alarm types, single and cumulative. However, while users dont choose any parameter in threshold value setting, it will be treated as NO alarm. Single event: an alarm is triggered immediately
Available Loggers are listed there. 3 loggers per page
Main Operation Functions are Here!
Rate, start/stop, alarm setting are here!