PS-24 Mains Adaptor
Mount the PS-24 box using the supplied holders
Package contents:
a) 4 holders
b) 4 wood screws
c) 4 screws for holders
d) 4 concrete plugs
(5mm drill)
e) 4 concrete screws
Using the supplied screws (c), attach the
plastic holders (a) to the PS-24 box.
(c)
(d)
(b)
(e)
(a)
ENGLISH
Using the appropriate screws for the wall material
(wood or concrete) and the weight of the unit,
mount the PS-24 power supply box on a flat surface
with the glands pointing downwards.
PS-24 Mains Adaptor
Alternative installation - PSU box
The vandal-proof PSU box is an optional accessory which can be mounted either on a pole
or on a flat surface.
1. Remove the top lid of the PSU box by
removing the 4 screws.
2. Place the PS-24 with the 4 cable glands
in the opening at the bottom of the PSU
box.
3. Replace the lid and lock it by tightening
the 4 screws.
4. Use the holder for the pole mount or use
the supplied screws to mount the PSU on
a pole or a flat surface.
5. Follow the instructions for the outdoor
housing to complete the installation.
Note:
• Use 4pcs. sleeve anchor with flange nut, drill size 6mm, M6, length >= 50mm (concrete screw, not included).
• Pole mount - the recommended pole diameter for this pole box is 130-140mm.
Screws
Cable
glands
Holder for
pole mount
Gooseneck
tube
Outdoor housing
for camera
Pole box mounting
Examples of installation (PSU box and pole/wall mount)
Gooseneck
tube
Outdoor housing
for camera
Wall box mounting
PS-24 Mains Adaptor
PS-24 Mains Power Adaptor
3
AC & DC Output
(not used)
Voltage selector switch
5
(115V/230V)
1
Terminal connectors
(To camera)
Outer ring
Cable gland
The outdoor power supply contains two sets of terminal connectors to provide easy wiring for alarm inputs/outputs
6-12mm
10-14mm
6
AC Input
230VAC/115VAC
Power switch
4
ON(1) OFF(0)
2
Terminal connectors
(From camera)
Important!
•Warning - high voltage. Read through the instructions before starting the installation. The electrical connection
should be made by an authorized electrician. Please observe relevant national and local regulations for the
installation.
•AXIS PS-24 is designed to be part of an IT power system. Ground is not connected internally in the power
supply.
ENGLISH
Cables
Power cable (not supplied) (6) AC Input connector Copper cables: AWG 16-18 or 1.5mm
Input cables (not supplied) (2) Terminal connectors AWG 16-28 or 1.5mm2 cables
AXIS PS-24 Specifications
AC Input: 100-120VAC / 220-240VAC, max 800mA / 400mA, 80VA
AC Output: 24VAC, max 63VA
2