This manual includes instructions for using and
managing the AXIS PoE MIDSPAN 8-Port/ AXIS PoE
Midspan 16-Port on your network. Later versions of
this document will be posted to the Axis Website.
Safety Notices Used In This
Manual
Caution! - Indicates a potential hazard that can
damage the product.
Important! - Indicates a hazard that can seriously
impair operation.
Do not proceed beyond any of the above notices until
you have fully understood the implications.
Intellectual Property Rights
Axis AB has intellectual property rights relating to
technology embodied in the product described in this
document. In particular, and without limitation, these
intellectual property rights may include one or more of
the patents listed at http://www.axis.com/patent.htm
and one or more additional patents or pending patent
applications in the US and other countries.
Electromagnetic Compatibility
(EMC)
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Re-orient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment to an outlet on a different
circuit to the receiver.
Consult your dealer or an experienced radio/TV
technician for help.
Shielded (STP) network cables must be used with this
unit to ensure compliance with EMC standards.
USA. This equipment has been tested and found to
comply with the limits for a Class B computing device
pursuant to Subpart B of Part 15 of FCC rules, which are
designed to provide reasonable protection against such
interference when operated in a commercial environment.
Operation of this equipment in a residential area is likely
to cause interference, in which case the user at his/her
own expense will be required to take measures required
to correct the interference.
Canada. This Class B digital apparatus complies with
Canadian ICES-003.
Europe. This digital equipment fulfills the
requirements for radiated emission according to limit B
of EN55022/1998, and the requirements for immunity
according to EN55024/1998 residential, commercial, and
light industry.
Japan. This is a class B product based on the standard
of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is
used near a radio or television receiver in a domestic
environment, it may cause radio interference. Install and
use the equipment according to the instruction manual.
Australia. This electronic device meets the
requirements of the Radio communications
(Electromagnetic Compatibility) Standard AS/NZS
CISPR22:2002.
Equipment Modifications
This equipment must be installed and used in st rict
accordance with the instructions given in the user
documentation. This equipment contains no
user-serviceable components. Unauthorized equipment
changes or modifications will invalidate all applicable
regulatory certifications and approvals.
Every care has been taken in the preparation of this
manual. Please inform your local Axis office of any
inaccuracy or omission. Axis Communications AB
cannot be held responsible for any technical or
typographical errors and reserves the right to make
changes to the product and manuals without prior notice.
Axis Communications AB makes no warranty of any
kind with regard to the material contained within this
document, including, but not limited to, the implied
warranties of merchantability and fitness for a particular
purpose. Axis Communications AB shall not be liable nor
responsible for incidental or consequential damages in
connection with the furnishing, performance or use of
this material.
Support
Should you require any technical assistance, please
contact your Axis reseller. If your questions cannot be
answered immediately, the reseller will forward your
queries through the appropriate channels to ensure a
rapid response. If you are connected to the Internet,
you can:
• Download user documentation and firmware
updates
• Find answers to resolved problems in the FAQ
database
• Search by product, category, or phrases
• Report problems to Axis support by logging in to
your private support area
• Visit Axis Support at www.axis.com/techsup/
RoHS
This product complies with both the European
RoHS directive, 2002/95/EC, and the Chinese
RoHS regulations, ACPEIP.
WEEE Directive
The European Union has enacted a Directive
2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE Directive).
This directive is applicable in the European
Union member states.
The WEEE marking on this product or its
documentation indicates that the product must not be
disposed of together with household waste. To prevent
possible harm to human health and/or the environment,
the product must be disposed of in an approved and
environmentally safe recycling process. For further
information on how to dispose of this product
correctly, contact the product supplier, or the local
authority responsible for waste disposal in your area.
Business users should contact the product supplier for
information on how to dispose of this product
correctly. This product should not be mixed with other
commercial waste.
AXIS PoE MIDSPAN 8-Port/AXIS PoE Midspan
16-Port is identical to the Phihong
PoE370U-480-8/PoE370U-480-16.
Please read the following carefully before installing and connecting the
system to a power source.
Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS
Note:
3260) should install, replace, or service the equipment. Install the system in accordance
with Country, National, or the U.S. National Electric Code if you are in the United
States.
Precautions
1. The building where this product is used requires a fuse or circuit
breaker no larger than 15 A for 120 VAC (U.S.A.) or 10 A, 230 VAC
(international). The building facility must protect the AXIS PoE
Midspans 8P/16P from over current or short-circuits.
2. Read the Midspan Hardware Setup procedure before connecting
the AXIS PoE Midspans 8P/16P to a power source (including
power cord requirements).
3. Do not operate the product in an area that exceeds the maximum
recommended ambient temperature of 104 ºF/ 40 ºC to avoid
overheating the AXIS PoE Midspans 8P/16P. Allow at least 3 to 4
inches/ 7.6 to 10.2 cm clearance around all ventilation openings.
4. Do not stack the chassis on any other equipment to support its
weight. Shelf mounted equipment requires a stable and durable
surface. Do not push or pull on the Midspan while installing.
5. The AXIS PoE Midspans 8P/16P consists of two rows of "Data”
and "Data & Power" ports. The ports use RJ-45 data sockets.
Connect only RJ-45 data cables to these sockets. Do not connect
telephone cables into these ports.
6. Do not work on the AXIS PoE Midspans 8P/16P system or connect
or disconnect cables, when there is lightning.
7. The AC or DC plug/socket combination must be accessible at all
times, as it is the main disconnect device to the product.
Safety InformationPage 7
8. Before servicing the product, always disconnect the product from
its AC source.
9. Abide by appropriate National laws and regulations when it comes
to discarding this product.
ENGLISH
ENGLISH
Page 8Safety Information
Power Cord Requirements
Power cords must meet the requirements for the country they are used in.
USA and Canada•The cord must have a minimum of 10A rated current competence.
•The cord must be CSA or UL approved.
•The minimum requirement for the flexible cord is:
•18 AWG (10A)
• Three-conductor (line, neutral, ground)
• Type SV (Stranded Vacuum Rubber Jacketed) or SJ (Stranded Junior Rubber
Jacketed) or SVT (Stranded Vacuum Rubber Jacketed Themoplastic) or SJT
(Stranded Junior Themoplastic)
• The plug must be earth-grounded with a NEMA 5-15P (15A, 125 V) or
NEMA 6-15P (15A, 250 V) configuration.
Europe and South America Switzerland: The supply plug must comply with SEV/ASE 1011.
Denmark: The supply plug must comply with section 107-2-D1, standard DK2-1a
or DK2-5a.
United Kingdom: The Midspan is covered by General Approval (section 16.16.060),
NS/G/12345/J100003, for indirect connection to a public telecommunication system
France and Peru: IT equipment cannot power this device. In the case of an IT powered device, the unit needs to be powered by 230 V through an isolation transformer with a ratio of 1:1 and the secondary connection (Neutral) is properly
grounded.
• The Midspan must have access to a power outlet. Disconnect the power
cord from the outlet, to eliminate power from the device.
• The flexible cord that connects to the Midspan must have a configuration to connect with an EN60320/IEC320 inlet connector.
• According to the EN60950/IEC 950 specifications, this device functions
under SELV (Safety Extra Low Voltage) conditions. The conditions are
true if the equipment and the connected device functions under SELV
conditions.
• The AXIS PoE Midspans 8P/16P meet the UL/
cUL per EN60950 safety standard. This is displayed in the back side of the product.
Hardware SetupPage 9
Front side of
AXIS PoE 16P
Midspan
Data
Data and Power
AC Power Connector at the back
Hardware Setup
Appearance
Data Input Ports
The AXIS PoE Midspans 8P/16P have 10Base-T/100Base-TX data input
ports, that have straight-wired configuration. These ports carry Ethernet
data (Tx/Rx) over the standard 2-wire pairs (pins 1/2 and 3/6).
ENGLISH
ENGLISH
Data and Power Output Ports
The AXIS PoE Midspans 8P/16P Data and Power ports have straight-wire
configuration. They are designed to carry Ethernet data and DC power over
the standard 2-wire pairs (pins 1/2 and 3/6; PoE mode A).
Page 10Installation
Installation
Connecting Power Cables
The AC power cable is connected to the AC power connector located in the
rear side of the AXIS PoE Midspans 8P/16P and the power outlet.
Connecting Ethernet Cables
The ports in the product’s front panel are configured as ‘route through’
ports for all the eight/ sixteen RJ-45 connectors. Use Category 5 cabling in
making connections.
1. Connect cables from the ethernet switch to the data ports - on the
bottom row of the AXIS PoE Midspans 8P/16P.
2. Connect the cables from the IEEE 802.3af powered devices to the
corresponding Data and Power ports on the top row of the AXIS
PoE Midspans 8P/16P.
Powering Up
AXIS PoE Midspans 8P/16P are powered by the power cord. In order to
apply or remove power to or from the Midspan, connect or disconnect the
AC power cable to or from the AC power connector on the rear side of the
unit.
With AC power the unit starts-up and the internal fans are active. The
device runs through a quick power-on test, which takes less than 10
seconds. During this period, all ports are initially disabled and the port
indicators light up. The sequence of the port LEDs are shown in the section
below - LED Indicator. Ports now operate under normal conditions.
InstallationPage 11
LED Indicator
Indicator
s
Power
LED
Data &
Power
OffGreenOrange
staticblinkingstaticblinking
Midspan
not powered
Port disabled
Midspan
powered
Port connected
Conditions
n/an/an/a
Port connected; data
port disconnected
Port has
an error
Port is disconnected,
but enabled
Rack-Mounting Installation
Position the Midspan on the rack. Arrange the mounting bracket to the
corresponding screw holes in the Midspan. Keep the screw area visible to
insert screws, and then tighten them.
ENGLISH
ENGLISH
Page 12Technical Specifications
Technical Specifications
ParametersSpecifications
Mechanical Specifications
Dimensions17.25 inch (438 mm) length
8.98 inch (228 mm) width
1.75 inch (44.5 mm) height
9lbs (4.08 Kg) weight
Environmental Specifications
TemperatureOperating: 32°F to 104°F (0°C to +40°C)
Non-Operating: -77°F to 149°F (-25°C to +65°C)
Relative HumidityOperating: 5% to 90%
Non-Operating: 5% to 90%
Maximum heat dissipation of the AXIS PoE Midspans 8P/16P
Electrical Specifications
AC Input voltage rating100VAC to 240VAC
AC Input voltage range90VAC to 264VAC
AC Input current5.5A (rms) at Max. load
AC Input frequency47Hz to 63H
Max. In-rush current30A for 115VAC at Max. load
AC Output voltage480: 50VDC
Max. load current480: 0.32A
Output Power, per port15.4W (not to exceed total output power)
Total Output Power No. of ports: 8 - 125W max, 16 - 250W max
Nominal Output Voltage 44VDC to 57VDC
Approvals•cUL/UL
AC mode =125W
60A for 230VAC at Max. load
56VDC: 56VDC
56VDC: 0.275A
•TUV
•CE
TroubleshootingPage 13
Troubleshooting
If problems occur with the Midspan, please refer to the table below. The
troubleshooting solutions provided can only solve minor problems. If your
problem is not listed, please contact our local office for further technical
assistance.
ProblemPossible Solutions
Midspan does not power up1. Ensure that AC power cord is connected.
2. Ensure that AC power cord is in good condition.
3. If neither of the above is the problem, disconnect
the AC power cord and reconnect. Observe Port LEDs
to verify proper power up.
AC LED unlitVerify if the Midspan is properly connected to an AC
power source.
Data and Power Port LED do not light 'green'Ensure Ports are connected to a Network.
Verify the following:
1. Power is applied to the Midspan
2. Network Ethernet cable is connected to the Data
port
3. Powered device Ethernet cable is connected to the
Data & Power port
4. The right kind of Ethernet cable is used; do not use
crossover-type Ethernet cable
5. Cable pairs are connected to corresponding ports.
ENGLISH
ENGLISH
Page 14Troubleshooting
Contenu de l'emballagePage 15
Contenu de l'emballage
•Midspan PoE
• Câble secteur
• Deux supports de montage en baie de 19 pouces
• Quatre vis à tête plate Philips M4 x 8 mm
• Déclaration de garantie AXIS
• 4 pieds en caoutchouc
•Manuel
FRANCAIS
Page 16Informations de sécurité
Informations de sécurité
Veuillez lire attentivement les informations qui suivent avant d'installer et
de connecter le système à une source d'alimentation.
Remarque :
Seul le personnel de maintenance qualifié et formé (conformément aux normes
IEC 60950 et AS/NZS 3260) est autorisé à installer, remplacer ou dépanner le matériel.
Installez le système conformément aux procédures en vigueur dans votre pays, ou au
U.S. National Electric Code si vous êtes aux États-Unis.
Précautions
1. Le bâtiment dans lequel ce produit doit être utilisé doit être muni
d'un fusible ou d'un disjoncteur n'excédant pas 15 A pour 120 Vca
(États-Unis) ou 10 A pour 230 Vca (international). L'installation du
bâtiment doit protéger le midspan AXIS PoE 8P/16P des
surtensions et des courts-circuits.
2. Consultez la procédure d'installation du matériel avant de
connecter le midspan AXIS PoE 8P/16P à une source
d'alimentation (notamment les conditions relatives au câble
d'alimentation).
3. N'utilisez pas le produit dans un local dépassant la température
ambiante maximale recommandée de 40 °C/104 °F, afin d'éviter la
surchauffe du midspan AXIS PoE 8P/16P. Prévoyez un
dégagement d'au moins 7,6 à 10,2 cm (3 à 4 pouces) au niveau de
tous les évents.
4. N'empilez pas le châssis sur d'autres appareils afin d'en soutenir le
poids. L'équipement monté sur étagère nécessite une surface stable
et résistante. Ne poussez pas ou ne tirez pas sur le midspan
pendant que vous l'installez.
5. Le midspan AXIS PoE 8P/16P comporte deux rangées de ports «
Données » et « Données & Alimentation ». Ces ports utilisent des
connecteurs de données RJ-45. Ne connectez pas de câbles
téléphoniques à ces ports. Connectez-y uniquement des câbles de
données RJ-45.
6. Ne travaillez pas sur le système midspan AXIS PoE 8P/16P et ne
connectez ou ne déconnectez aucun câble en cas d'orage.
Informations de sécuritéPage 17
7. La combinaison fiche/prise CA ou CC doit être accessible à tout
moment, car elle constitue le principal dispositif de déconnexion
du produit.
8. Avant toute intervention sur le produit, débranchez-le toujours de
sa source de CA.
9. Adhérez à la réglementation nationale appropriée pour la mise au
rebut du produit.
FRANCAIS
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.