This document includes instructions for installing the AXIS
P3353/P3354/P3363-V/P3364-V/P3364-LV on your network.
Previous experience of networking will be beneficial when
installing the product.
Legal Considerations
Video and audio surveillance can be prohibited by laws that vary
from country to country. Check the laws in your local region
before using this product for surveillance purposes.
This product includes one (1) H.264 decoder license. To purchase
further licenses, contact your reseller.
Trademark Acknowledgements
Apple, Boa, Bonjour, Ethernet, Internet Explorer, Linux,
Microsoft, Mozilla, Real, SMPTE, QuickTime, UNIX, Windows,
Windows Vista and WWW are registered trademarks of the
respective holders. Java and all Java-based trademarks and
logos are trademarks or registered trademarks of Oracle
and/or its affiliates. UPnPTM is a certification mark of the
UPnPTM Implementers Corporation.
Electromagnetic Compatibility (EMC)
This equipment has been designed and tested to fulfill applicable
standards for:
• Radio frequency emission when installed according to the
instructions and used in its intended environment.
• Immunity to electrical and electromagnetic phenomena when
installed according to the instructions and used in its intended
environment.
USA - This equipment has been tested using a shielded
network cable (STP) and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
Canada - This Class B digital apparatus complies with
Canadian ICES-003.
Europe - This digital equipment fulfills the
requirements for RF emission according to the Class B limit of
EN 55022.
This product fulfills the requirements for immunity according to
EN 61000-6-1 residential, commercial and light-industry
environments.
This product fulfills the requirements for immunity according to
EN 61000-6-2 industrial environments.
This product fulfills the requirements for immunity according to
EN 55024 office and commercial environments.
Australia - This digital equipment fulfills the requirements
for RF emission according to the Class B limit of AS/NZS CISPR
This product complies with EN/IEC/UL 60950-1, Safety of
Information Technology Equipment.
Equipment Modifications
This equipment must be installed and used in strict accordance
with the instructions given in the user documentation. This
equipment contains no user-serviceable components.
Unauthorized equipment changes or modifications will
invalidate all applicable regulatory certifications and approvals.
Liability
Every care has been taken in the preparation of this document.
Please inform your local Axis office of any inaccuracies or
omissions. Axis Communications AB cannot be held responsible
for any technical or typographical errors and reserves the right
to make changes to the product and documentation without
prior notice. Axis Communications AB makes no warranty of any
kind with regard to the material contained within this
document, including, but not limited to, the implied warranties
of merchantability and fitness for a particular purpose. Axis
Communications AB shall not be liable nor responsible for
incidental or consequential damages in connection with the
furnishing, performance or use of this material.
RoHS
This product complies with both the European RoHS
directive, 2002/95/EC, and the Chinese RoHS
regulations, ACPEIP.
WEEE Directive
The European Union has enacted a Directive
2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). This directive is
applicable in the European Union member states.
The WEEE marking on this product (see right) or its
documentation indicates that the product must not
be disposed of together with household waste. To prevent
possible harm to human health and/or the environment, the
product must be disposed of in an approved and environmentally
safe recycling process. For further information on how to dispose
of this product correctly, contact the product supplier, or the
local authority responsible for waste disposal in your area.
Business users should contact the product supplier for
information on how to dispose of this product correctly. This
product should not be mixed with other commercial waste. For
more information, visit www.axis.com/techsup/commercial
waste
Support
Should you require any technical assistance, please contact your
Axis reseller. If your questions cannot be answered immediately,
your reseller will forward your queries through the appropriate
channels to ensure a rapid response. If you are connected to the
Internet, you can:
• download user documentation and firmware updates
• find answers to resolved problems in the FAQ database. Search
by product, category, or phrases
• report problems to Axis support by logging in to your private
support area.
Please read through this Installation Guide carefully before installing the Axis product. Keep the
Installation Guide for further reference.
• Store the Axis product in a dry and ventilated environment.
• Avoid exposing the Axis product to vibration, shocks or heavy pressure. Do not install the
product on unstable brackets, unstable or vibrating surfaces or walls, since this could cause
damage to the product.
• Only use applicable tools when installing the Axis product; excessive force could cause
damage to the product.
• Do not use chemicals, caustic agents, or aerosol cleaners. Use a damp cloth for cleaning.
• Use only accessories that comply with technical specification of the product. These can be
provided by Axis or a third party.
• Use only spare parts provided by or recommended by Axis.
• Do not attempt to repair the product by yourself, contact Axis or your Axis reseller for service matters.
• This Axis product shall be used in compliance with local laws and regulations.
• To use this Axis product outdoors, it shall be installed in an approved outdoor housing.
• The Axis product should be installed by a trained professional. Observe relevant national
and local regulations for the installation.
Transportation
ENGLISH
• When transporting the Axis product, use the original packaging or equivalent to prevent
damage to the product.
Battery Replacement
This Axis product uses a 3.0 V CR2032 lithium battery as the power supply for its internal real-time
clock (RTC). Under normal conditions this battery will last for a minimum of 5 years. Low battery
power affects the operation of the RTC, causing it to reset at every power-up. A log message will
appear when the battery needs replacing. The battery should not be replaced unless required!
If the battery does need replacing, please contact www.axis.com/techsup for assistance.
• Dispose of used batteries according to the manufacturer's instructions.
• Risk of explosion if battery is incorrectly replaced.
• Replace only with the same or equivalent battery, as recommended by the manufacturer.
Dome Cover Cleaning
• Be careful not to scratch or damage the dome cover. Keep the protective plastic on the
dome cover until the installation is complete. Do not clean a dome cover that looks clean to
the eye and never polish the surface. Excessive cleaning could damage the surface.
• For general cleaning of a dome cover it is recommended to use a non-abrasive, solvent-free
neutral soap or detergent with water and a soft cloth. Rinse well with clean lukewarm
water. Dry with a soft cloth to prevent water spotting.
• Never use harsh detergents, gasoline, benzene or acetone etc. and avoid cleaning in direct
sunlight or at elevated temperatures.
• Domes for L products come with an anti-scratch surface. Avoid leaving finger prints on the
dome surface since this might impair image quality.
AXIS P33 Network Camera Installation GuidePage 5
AXIS P33 Network Camera Installation Guide
This installation guide provides instructions for installing an
AXIS P3353/P3354/P3363-V/P3364-V/P3364-LV Network Camera on your network. For all other
aspects of using the product, please see the User Manual, available on www.axis.com
1. “Package contents” on page 5
2. “Hardware overview” on page 6
3. “Mount the camera” on page 7
4. “Access the video stream” on page 8
5. “Adjust the Lens” on page 8
6. “Complete the installation” on page 9
Notes:
• Before you begin, make sure that the package contents, the required cables, tools,
and documentation are available. See Package contents below.
• This network camera is intended to operate with PoE; if not available use AXIS PoE Midspan 1 port (not
See www.axis.com for information on available accessories
ENGLISH
Page 6 AXIS P33 Network Camera Installation Guide
Network connector
LED indicators
I/O connector
(PoE)
Camera unit
Network cable
Dome cover
out
Audio in
SD memory card slot
Wall screws
Audio
Camera unit
Fan output
connector
Built-in microphone
Control button
Camera: P3363/P3364
Hardware overview
Note:
• AXIS P3353 and AXIS P3354 do not support I/O or audio.
• Make sure the switch under the camera is configured to PoE class 3 with regard to IR illumination (AXIS
P3364-LV), which will not work if configured otherwise.
Dimension (HxWxD)
AXIS P3353/AXIS P3354/AXIS P3363-V /AXIS P3364-V/AXIS P3364-LV = 97 x 148 x 148 mm (3.82 x
5.83 x 5.83")
Weight
AXIS P3353/AXIS P3354 = 430 g (0.9 lb.)
AXIS P3363-V /AXIS P3364-V = 650 g (1.4 lb.)
AXIS P3364-LV = 670 g (1.5 lb.)
AXIS P33 Network Camera Installation GuidePage 7
Metal conduit (Optional/not included)
Mounting bracket (Optional/not included)
Network cable
M4x8 screw
Wall screws
Network cable
Mount the camera
This Axis product can be mounted with the cables routed through or along the wall. This product
can also be fitted with a metal conduit for protecting the cabling when they are routed along the
wall. See the illustration that follows.
Mount camera directly onto the wall
1. Using the drill template drill 2 holes in the wall.
2. Route and connect the network cable.
3. Attach the camera unit to the wall using screws and plugs appropriate for the wall material.
Mount camera using a mounting bracket (not included)
1. Using the drill template drill 2 holes in the wall.
2. Route the network cable through the wall and through the holes in the mounting bracket.
3. Attach the mounting bracket to the wall, using screws and plugs appropriate for the wall
material.
4. Connect the network cable.
5. Optionally connect the I/O and audio cables; see page 10 for details.
6. Optionally insert the SD memory card.
7. Attach the camera unit to the mounting bracket using two appropriate screws.
Note:
• These instructions are for mounting the camera on a wall. The mounting bracket can also be used for
mounting the network camera to a junction box.
• AXIS P3353 and AXIS P3354 do not support audio and I/O.
ENGLISH
Page 8 AXIS P33 Network Camera Installation Guide
Locking screw
Lens holder
Lens
(Horizontal) line
Mark
Optical shield
Access the video stream
Use the tools provided on the Installation and Management Software CD to assign an IP address,
set the password and access the video stream. This information is also available from the support
pages on www.axis.com/techsup.
Adjust the Lens
Open the Live View page in the web interface and make the following adjustments to the camera:
1. Loosen the locking screw.
2. Turn the lens holder to the desired position.
3. Turn the lens to ensure the lines on either side of the lens are aligned horizontally.
Ensure that the mark on the lens cover, between the horizontal lines, is facing up.
Note:
4. Once satisfied, gently tighten the locking screw to secure the camera’s position.
5. Open the Focus Adjustment page in the Web interface under Setup > Basic Setup > Focus & Zoom, and follow the on-screen instructions. Use the image window to adjust the zoom and
focus. See the online help files for more information.
Note:
• Due to the dome’s refraction, the image may appear slightly out of focus once the dome has been placed.
To correct this go to the Focus Adjustment page in the Web interface under Setup > Basic Setup > Focus & Zoom, and adjust the focus again.
• When the zoom and focus are adjusted, the IR illumination is automatically aligned to the defined angle
of view.
Warning! Adjusting the focus and zoom manually can damage the lens.
AXIS P33 Network Camera Installation GuidePage 9
Side lid
Dome cover
Camera unit
Network cable
Dome cover
Complete the installation
1. If the cables are routed along the wall, remove the side lid from the camera’s dome cover.
2. Rotate the black protective shield inside the dome casing to match the camera’s position (not
applicable to AXIS P3364-LV).
3. Clean the dome with a dry soft cloth to remove dust and finger prints and use a blower to
remove dust from the lens.
4. Mount the dome casing using the supplied tamper-proof screws and screw driver. Now that the
dome is in place, check that the camera is properly focused.
AXIS P3364-LV: Before attaching the dome cover make sure the optical shield sits well in place.
Note:
See image on page 8.
For the AXIS P3364-LV, when the lens holder is tilted at a certain angle the dome cover may block
part of the IR illumination. In that case:
• loosen the locking screw
• rotate the lens holder 180°
• tighten the locking screw
• for correct image orientation, rotate the lens by 180°; make sure the horizontal lines are aligned and the
mark between them is facing up.
The installation is now complete.
ENGLISH
Page 10 AXIS P33 Network Camera Installation Guide
Unit connectors
Note: AXIS P3353 and AXIS P3354 do not support audio or I/O.
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet.
The product shall be connected using a shielded network cable (STP). All cables connecting the product
to the network switch shall be shielded (STP) and intended for their specific use. Make sure that the network switch is properly grounded. See Electromagnetic Compatibility (EMC) on page 2 for regulatory
requirements.
For AXIS P3364-LV, if not using the IR LED/heater/fan, change to PoE class 2 using the button on
the back of the camera to minimize power consumption.
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is used from
a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system or an
active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo
connector must be used for the audio out.
SDHC memory card slot - The SD memory card can be used for local recording with removable
storage.
I/O terminal connector - Use with external devices in combination with, for
example, tampering alarms, motion detection, event triggering, time lapse
recording and alarm notifications. In addition to the 0 V DC reference point
and power (DC output), the I/O connector provides the interface to:
• Digital output - For connecting external devices such as relays
and LEDs. Connected devices can be activated by the VAPIX
® Application Programming
Interface, output buttons on the Live View page or by an Action Rule. The output will
show as active (shown under System Options > Ports & Devices) if the alarm device is
activated.
• Digital input - An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc.
When a signal is received the state changes and the input becomes active (shown
under System Options > Ports & Devices).
4 3 2 1
FunctionPinNotesSpecifications
0 V DC (-)10 V DC
DC output2Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3.3 V DC
Max load = 50 mA
AXIS P33 Network Camera Installation GuidePage 11
3.3 V max 50 mA
1
2
3
4
FunctionPinNotesSpecifications
Digital
Input
Digital
Output
3Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate
4Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an
inductive load, e.g. a relay, a diode must be
connected in parallel with the load, for protection
against voltage transients.
0 to max 40 V DC
0 to max 40 V DC,
open drain, 100 mA
ENGLISH
LED indicators
LEDColorIndication
NetworkGreenSteady for connection to a 100 Mbit/s network. Flashes for network activity.
StatusGreenSteady green for normal operation.
PowerGreenNormal operation.
AmberSteady for connection to 10 Mbit/s network. Flashes for network activity.
UnlitNo network connection.
AmberSteady during startup, during reset to factory default or when restoring settings.
RedSlow flash for failed upgrade.
AmberFlashes green/amber during firmware upgrade.
Page 12 AXIS P33 Network Camera Installation Guide
Resetting to the Factory Default Settings
This will reset all parameters, including the IP address, to the factory default settings:
1. Disconnect power from the camera.
2. Press and hold the Control button and reconnect power (see Hardware overview, on page).
3. Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber.
4. Release the Control button. The process is complete after about 1 minute (when the Status
indicator turns green). The network camera has been reset to the factory default settings. The
default IP address is 192.168.0.90
5. Re-assign the IP address.
6. Refocus the camera.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System
Options > Maintenance.
Further information
The user manual is available from the Axis Web site at www.axis.com.
To learn more about Axis' products and technologies, visit www.axis.com/academy, global learning
center for network video.
Tip!
Visit www.axis.com/techsup to check if there is updated firmware available for your Axis product.
To see the currently installed firmware version, see Setup > About in your web interface.
Warranty
For information about Axis' product warranty and thereto related information, please see
www.axis.com/warranty
Mesures de sécurité
Lisez attentivement le présent Guide d'installation avant d'installer le produit Axis. Conservez le
Guide d'installation pour une utilisation ultérieure.
• Conservez le produit Axis dans un environnement sec et aéré.
• Évitez d'exposer le produit Axis aux vibrations, aux chocs ou à une forte pression.
N'installez pas le produit sur un support instable, ou des surfaces ou des murs instables ou
vibrants, car cela pourrait l'endommager.
• N'utilisez que les outils applicables pour installer le produit Axis ; une force excessive
pourrait endommager le produit.
• Pour le nettoyage, n’utilisez ni produits chimiques, ni substances caustiques ou aérosols.
Utilisez un chiffon humide pour le nettoyage.
• N’utilisez que des accessoires conformes aux caractéristiques techniques du produit. Ceux-
ci peuvent être fournis par Axis ou par un fournisseur tiers.
• Utilisez uniquement des pièces de rechange fournies ou recommandées par Axis.
• Ne tentez pas de réparer le produit vous-même, contactez Axis ou votre revendeur Axis
pour toute réparation.
• Ce produit Axis doit être utilisé conformément aux lois et réglementations locales en
vigueur.
• Pour pouvoir être utilisé à l'extérieur, ce produit Axis doit être placé dans un boîtier
d'extérieur homologué.
• Le produit Axis doit être installé par un professionnel qualifié. Veuillez vous conformer aux
règlements nationaux et locaux relatifs à l'installation.
FRAN
Ç
AIS
Transport
• Pour transporter le produit Axis et éviter de l'endommager, utilisez l'emballage d'origine ou
un emballage équivalent.
Remplacement des piles
Ce produit Axis nécessite une pile au lithium CR2032 de 3,0 V pour l'alimentation de son horloge en
temps réel interne. Dans des conditions normales d'utilisation, cette pile est censée durer au moins
5 ans. Si la pile est faible, le fonctionnement de l'horloge en temps réel peut être affecté et
entraîner sa réinitialisation à chaque mise sous tension. Un message enregistré apparaît lorsque la
pile doit être remplacée. Ne remplacez la pile qu'en cas de nécessité !
Si la pile doit être remplacée, veuillez contacter www.axis.com/techsup pour obtenir de l’aide.
• Jetez les piles usagées conformément aux consignes du fabricant.
• Le remplacement incorrect de la pile peut entraîner un risque d'explosion.
• Remplacez la pile par une pile identique ou équivalente uniquement, en respectant les
recommandations du fabricant.
Nettoyer la bulle du dôme
• Veillez à ne pas rayer ou endommager la bulle du dôme. Ne nettoyez pas la bulle du dôme si
elle semble propre à l'œil nu et ne frottez jamais sa surface. Un nettoyage excessif peut
l'endommager.
• Pour le nettoyage général de la bulle du dôme, il est recommandé d'utiliser un savon ou un
détergent neutre sans solvant, non abrasif, avec de l'eau et un chiffon doux. Rincez
abondamment avec de l’eau tiède et propre. Séchez à l'aide d'un chiffon doux pour éviter
les tâches d'eau.
• N'utilisez jamais de détergents forts, d'essence, de benzène ou d'acétone, etc. et évitez
toute exposition directe aux rayons du soleil ou à des températures élevées lors du
nettoyage.
• Les bulles pour les produits L sont livrées avec une surface anti-rayures et le nettoyage de
la bulle est recommandé, cependant veuillez respecter les précautions ci-dessus.
Ce guide d’installation explique comment installer la
Caméra réseau AXIS P3353/P3354/P3363-V/P3364-V/P3364-LV sur votre réseau. Pour toute autre
question concernant l’utilisation du produit, reportez-vous au manuel d’utilisation, que vous
trouverez sur le site www.axis.com.
1. “Contenu de l’emballage” à la page 15
2. “Présentation du matériel” à la page 16
3. “Montage de la caméra” à la page 17
4. “Accéder au flux video” à la page 18
5. “Réglage de l’objectif” à la page 18
6. “Fin de l’installation” à la page 19
Remarques :
• Avant de commencer, vérifiez le contenu de l’emballage et assurez-vous que les câbles, les outils
et la documentation nécessaires sont disponibles. Voir Contenu de l’emballage ci-dessous.
• Cette caméra réseau est conçue pour fonctionner avec un connecteur réseau (PoE). Si vous n’en disposez
pas, utilisez Axis PoE Midspan à 1 port (non fourni).
FRAN
Ç
AIS
Contenu de l’emballage
ÉlémentModèles/variantes/remarques
Caméra réseauAXIS P3353, AXIS P3354, AXIS P3363-V
Bulles de dômeBulle transparente non fumée (non applicable pour l’AXIS P3364-LV)
Étiquettes2 étiquettes adhésives portant le numéro de série
Kit de montageTournevis Resitorx, gabarit de perçage, connecteur de connexion
CDCD du logiciel d'installation et de gestion
Documentation impriméeGuide d’installation (le présent document)
Accessoires en optionSupport de fixation (spécifique à la région)
AXIS P3364-V, AXIS P3364-LV
Bulle transparente fumée
Clé d’authentification AVHS
Consultez le site www.axis.com pour plus d’informations sur les accessoires
disponibles
Ce produit peut être monté avec les câbles d’alimentation acheminés à travers ou le long du mur.
Ce produit peut également être doté d’un conduit métallique pour protéger le câblage lors d’un
acheminement des câbles le long du mur. Référez-vous à l’illustration suivante.
Montage de la caméra directement sur le mur
1. En vous servant du gabarit de perçage, percez 2 trous dans le mur.
2. Acheminez et branchez le câble réseau.
3. Fixez la caméra au mur à l’aide de vis et de chevilles appropriées.
Installez la caméra au moyen d’un support de fixation (non fourni).
1. En vous servant du gabarit de perçage, percez 2 trous dans le mur.
2. Acheminez tous les câbles à travers le mur et à travers les orifices du support de fixation.
3. Fixez le support de fixation au mur à l’aide de vis et de chevilles appropriées.
4. Branchez le câble réseau.
5. Vous pouvez aussi brancher les câbles E/S et audio. Pour plus d’informations, reportez-vous à la
page 20.
6. Si vous le souhaitez, insérez la carte mémoire SD.
7. Fixez la caméra au support de fixation à l’aide de deux vis appropriées.
Remarque :
• Ces instructions concernent l’installation de la caméra sur un mur. Le support de fixation peut aussi être
utilisé pour monter la caméra réseau à un boîtier de jonction.
• L’AXIS P3353 et l’AXIS P3354 ne prennent pas en charge les câbles E/S et audio.
Utilisez le logiciel fourni sur le CD du logiciel d'installation et de gestion pour attribuer une adresse
IP, définir le mot de passe et accéder au flux vidéo.
Réglage de l’objectif
Ouvrez la page Live View (Vidéo en direct) dans l’interface Web et effectuez les réglages suivants
sur la caméra :
1. Dévissez la vis de verrouillage.
2. Tournez le porte-objectif dans la position souhaitée.
3. Tournez l’objectif de manière à ce que les lignes (horizontales) de chaque côté de l’objectif
soient alignées horizontalement.
Remarque :
Assurez-vous que la marque sur le couvercle de l’objectif, entre les lignes horizontales, est
dirigée vers le haut.
4. Une fois que vous avez terminé, serrez délicatement la vis de verrouillage pour bien fixer la
caméra.
5. Ouvrez la page Focus Adjustment (Réglage de la mise au point) de l’interface Web sous Setup > Basic Setup > Focus & Zoom (Configuration > Configuration de base > Mise au point et
zoom), et suivez les instructions à l’écran. Utilisez la fenêtre d’image pour régler le zoom et la
mise au point. Reportez-vous à l’aide en ligne pour plus d’informations.
Remarque :
• Du fait de la réfraction du dôme, l’image peut apparaître légèrement floue une fois le dôme installé. Pour
corriger l’image, ouvrez la page Focus Adjustment (Réglage de la mise au point) de l’interface Web sous
Setup > Basic Setup > Focus & Zoom (Configuration > Configuration de base > Mise au point et zoom)
et réglez à nouveau la mise au point.
• Une fois le zoom et la mise au point réglés, la lumière infrarouge est automatiquement alignée sur
l’angle de vue défini.
Avertissement ! Le réglage manuel de la mise au point et du zoom peut endommager l’objectif.
1. Si les câbles doivent être acheminés le long du mur, enlevez le couvercle latéral de la bulle du
dôme de la caméra.
2. Tournez l’écran protecteur noir à l’intérieur du boîtier du dôme, conformément à la position de
la caméra (non applicable pour l’AXIS P3364-LV).
3. Nettoyez le dôme à l’aide d’un chiffon doux et sec pour enlever la poussière et les traces de
doigts. Dépoussiérez l’objectif avec un ventilateur.
4. Montez le boîtier du dôme à l’aide des vis inviolables et du tournevis fournis. Une fois le dôme
en place, faites une vérification de la mise au point de la caméra.
Remarque :
• Dévissez la vis de verrouillage.
• Tournez le porte-objectif de 180°.
• Serrez la vis de verrouillage.
• Pour une bonne orientation de l’image, tournez l’objectif de 180°. Assurez-vous que les lignes horizontales
AXIS P3364-LV: Avant de fixer le couvercle du dôme veuillez-vous assurer que la protection
optique est bien en place. Voir illustration ci-dessus (page 18).
Pour l’AXIS P3364-LV, lorsque le porte-objectif est incliné selon un certain angle, la bulle du dôme
peut bloquer la lumière infrarouge. Dans ce cas :
sont alignées et que la marque entre elles est dirigée vers le haut.
L'installation est maintenant terminée.
FRAN
Ç
AIS
Loading...
+ 43 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.