Axis B0.6D, B2D, B3D, B1.5D, B6D User Manual

USER MANUAL
File: R-B-043-04-09 B42_0 GB
2
USER MANUAL
_____________________________________________________________________________________________________________________
Contents:
1. General description....................................................................................................... 3
2. Completeness............................................................................................................... 3
3. Technical data............................................................................................................... 4
4. Keys and indicators....................................................................................................... 5
5. Security rules ................................................................................................................ 6
6. Environment protection ................................................................................................. 6
7. Preparation ................................................................................................................... 7
8. Start-up......................................................................................................................... 8
9. General rules ................................................................................................................ 9
10. Balance checking .................................................................................................... 11
11. Scale adjustment..................................................................................................... 11
12. Connecting a computer or a printer (optional) ......................................................... 11
13. Special functions description................................................................................... 14
14. Normal weighing...................................................................................................... 15
15. Weighing with tare................................................................................................... 15
16. Increased readability ............................................................................................... 15
17. Autozero (F..-AUt) ................................................................................................... 16
18. Funkcja liczenia sztuk (F..-PCS).............................................................................. 17
19. Printer cooperation settings (F..-LPt)....................................................................... 18
20. Serial port parameters setting (F..-rS) ..................................................................... 19
21. Constant tare (F..-tAr) ............................................................................................. 20
22. Function Menu customisation (F..-ACt) ................................................................... 22
23. Maintenance and repairs of small defects ............................................................... 23
Declaration of Conformity................................................................................................... 24
USER MANUAL
3
_____________________________________________________________________________________________________________________
1. General description
B series platform scales are destined for general use. All scales are metrologically tested - calibration or legal verification on demand.
B series scales are made in two main versions: with LED display (basic) and with LCD display (option). Standard indicator may be changed by indicator with additional keys – see appendix B. Scales have following verification features:
- a seal protecting scale casing against opening,
- notified body stamps and green metrological marking placed on the balance name plate.
Legal verification is valid for 3 years unless the seal is broken. NACE classification: : 29.24.23. Certificates:
EC Type
Approval Certificate
No. PL 04 022
Health Quality
Certificate
No. Hś/06458/01
AXIS management System
Certificate
DIN EN ISO 9001:2000
No. 78 100 6386
2. Completeness
Standard set consist of:
1. Scale
2. User Manual
3. Guarantee card
4. Feeder ZN12V/500mA (option)
5. Charger PA6V (option)
4
USER MANUAL
_____________________________________________________________________________________________________________________
3. Technical data
Scale type B15W
B30
B60
B120 B150 B200 B300
Maximum loading 15kg 30kg
60kg
120kg 150kg 200kg 300kg
Minimum loading 100g 200g 400g
1kg
1kg 1kg 2kg
Reading unit (d) 5g
*1g
10g
*5g *1g
20g
*10g
*5g *2g
50g
*10g
50g
*10g
50g
*10g
100g
*10g
Verification unit (e) 5g 10g
20g
50g 50g 50g 100g
Accuracy class III Working temperature -10 ÷ +40°C Tare range -15kg -30kg -60kg
-120kg -150kg -200kg -
300kg
Weighing time <4s Pan dimensions 380x380mm 400x500mm 400x400mm
600x500mm
Scale base dimensions 400x540x100 400x650x125mm 400x550x130
600x650x150mm Scale height 585mm 740mm Power supply 230V, 50Hz, 8VA Internal feeding (option) accumulator 6V/12Ah Accumulator working time ok. 50 godz. Scale weight 13kg 23kg
23kg
21kg
35kg 35kg 35kg
EC Verification
Scale type B33
B63
B151
B152
B301
Maximum loading 30kg
60kg
150kg
150kg
300kg
Minimum loading 200g
400g
1kg
1kg
2kg
Reading unit (d) 10g
*5g *1g
20g
*10g
*5g *2g
50g
*10g
50g
*10g
100g
*10g
Verification unit (e) 10g
20g
50g
50g
100g
Accuracy class III Working temperature -10 ÷ +40°C Tare range -30kg
-60kg
-150kg
-150kg
-300kg Weighing time <4s Pan dimensions 600x500mm 800x800mm 400x400mm 800x800mm Scale base dimensions 600x650x150mm 800x950
x160mm
400x550 x130mm
800x950 x160mm
Scale height 35kg 50kg
21kg
60kg Power supply 740mm Internal feeding (option) 230V, 50Hz, 8VA Accumulator working time accumulator 6V/12Ah Scale weight ok. 50 godz. (opcja) EC Verification
* increased readability for non-EC verification applications
USER MANUAL
5
_____________________________________________________________________________________________________________________
4. Keys and indicators
key I/ - switch-on / switch-off (standby), key
→T←
- tare (subtract package weight from weighed mass),
key
→0←
- zeroing (when the platform is empty),
key
- result printout, key MENU - special function menu, key B/G - gross, key HR - high resolution, indicator
→→→→0←←←←
- zero indicator, indicator
- result stabilization indicator, indicator NET - net weight indicator (indication with subtracted tare)
indicator
- gross mass (after use of B/G key), indicator
- indicator of pieces counting (indications in pieces)
LCD option:
indicator
MODE - special function setting,
bar indicator
- total load indicator (graduated 0-100%) indicator OFF - standby, indicator B/G - gross mass (key B/G), indicator pcs - pieces counting
Max, Min, d, e, III - metrological parameters and accuracy class.
I/
metrological data
6
USER MANUAL
_____________________________________________________________________________________________________________________
5. Security rules
To avoid electrical shock or damage of the scale or
connected peripheral devices, it is necessary to follow
the security rules below.
All repairs and necessary regulations can be made by authorised personnel only.
To avoid fire risk use a feeder of an appropriate type (supplied with the scale). Pay attention that supply voltage is compatible with specified technical data.
Do not use the scale when its cover is opened.
Do not use the scale in explosive conditions.
Do not use the scale in high humidity.
If the scale seems not to operate properly, unplug it from the mains and do
not use until checked by authorised service.
6. Environment protection
According to legal regulations it if forbidden to dispose
wasted electronic equipment in waste containers.
Please return wasted scale to the point of purchase or other company specialised in recycling of wasted electronic components.
USER MANUAL
7
_____________________________________________________________________________________________________________________
7. Preparation
1. Take the scale out of the package removing protective foils.
2. Take a pan off and remove protective elements from below the pan.
3. Place the scale on a stable ground not affected by mechanical vibrations and airflows.
4. Level the scale with the rotating rear legs so that the air bubble in the water-level at the back of the scale is in the middle. Lock the legs with the nut.
5. Put on the pan.
6. Remove everything from a pan and plug a scale to the mains with a ground contact. After self-tests and result stabilisation, the scale displays zero indication.
7. In scales with external feeder connect feeder plug to a connector on a display post. Plug a feeder to the mains (~230V, ground connector is not necessary).
To feed a scale use only socket with a ground connector.
Correct Wrong
8
USER MANUAL
_____________________________________________________________________________________________________________________
8. Start-up
Leave the pan empty, plug a scale to the mains with a ground contact The scale proceeds with following start-up actions:
Display test.
Basic electronic components tests: C1, C-2, ... C-6.
Program version.
The scale is now ready to work.
Loading...
+ 16 hidden pages