Axis AX-SLM Installation Manual

Page 1
SALAMANDER (ELECTRIC) AX-SLM
USER’S MANUAL
PRODUCTION YEAR: SERIAL NO
3096790
MVP GROUP CORPORATION 5659 ROYALMOUNT MONTREAL, QC. CANADA H4P 2P9
Tel: (514)737-9701 Fax: (514)342-3854
PUBLISHED ON : 09.05.2009
Page1 of 13
Page 2
TABLE OF CONTENTS
PAGE NR. TOPICS
1 COVER PAGE 2 TABLE OF CONTENTS 3 INTRODUCTION 4 TECHNICAL DATA
5 ELECTRICAL CIRCUIT DIAGRAM / MAIN DIMENSIONS 6 WARNING SIGNS 7 SAFETY DETAILS 8 TRANSPORTING AND MOVING 9 INSTALLATION OF THE APPLIANCE
10-11 OPERATION OF THE APPLIANCE
12 TERMS OF WARRANTY
CAUTION
This appliance should only be used in facilities where standards,
local safety codes and regualtions are followed.
2/13
Page 3
INTRODUCTION
Dear User,
Thank you for purchasing our AXIS product and for your confıdence in our
company. Our appliances are produced in compliance with international
standards. IMPORTANT: Please read and ensure that all users read this
manual in order to achieve the desired performance that you expect; and to
enable you to use this AXIS appliance for many years.
Please read and ensure that your operation personnel read this user’s
manual carefully before installing and using the appliance.
The manual containing information about installation, usage and
maintenance of our product you purchased should be read carefully.
Please ensure that power supply connections to the appliance are
already installed by qualified personnel according to local regulations,
before our authorized service arrive for any service work to this
appliance. If our authorized service determines that the necessary
repair(s) to be done are a result of the faulty installation on your part,
the warranty shall not be covered.
If you do not have enough information, please
contact our customer
service department either by phone at
1-514-737-9701 or e-mail at:
service@mvpgroupcorp.com
We expect you to have the best performance
from our product!
3/12
Page 4
TECHNICAL DATA
YOUR PRODUCT'S TYPE
MAIN DIMENSIONS (inches) 23.6” x 24.0” x 22.8”
TOTAL ELECTRICAL INPUT (kW) 3,6
POWER SUPPLY VOLTAGE (V) 220
WORKING FREQUENCY (Hz) 60
NET WEIGHT (Lbs) 114
AX-SLM
4/13
Page 5
ELECTRICAL CIRCUIT DIAGRAM
H1
KLEMENS
N L1
S1
R1
CODE COMPONENTS
S1 Strom regulator
MAIN DIMENSIONS
23.6”
H1 appliance ON lamp R1 Heating Element
24.0”
22.8”
5/13
Page 6
WARNING SIGNS
PE
POWER NETWORK GROUNDING
POWER
POWER SUPPLY CONNECTIONS
208/220V / 60 Hz / 1
GROUNDING
OVERHEAT
6/13
Page 7
SAFETY DETAILS
The appliance should only be operated under a hood.
Any kind of flammable solid and liquid material (cloths, alcohol and derivatives, petrochemical products, wooden and plastic materials, cutting blocks, curtains etc.) should never be held near the appliance.
You can use this appliance simultaneously together with other products
Do not clean up the appliance with pressure water
This appliance should be installed in line with
effective regulations and only be operated in well ventilated places. Please refer to the instructions before installing and operating the appliance.
This appliance is designed for industrial use and should only be operated by personnel trained on the appliance.
The appliance should not be handled by
unauthorized person except for the manufacturer or
authorized service.
In case of fire or flame in the area where the appliance is operated, act without panic, close gas valves, turn off the power switches and use a fire extinguisher. Never use water to extinguish the fire.
7/13
Page 8
TRANSPORTING AND MOVING
CHANGING THE LOCATION;
Machines installed by an authorized service CANNOT BE MOVED ELSEWHERE, ITS POWER SUPPLY CABLES CANNOT BE EXTENDED OR REPLACED except by an authorized service.
Before transporting device should be disconnected from power.
Do not hit or drop the device when moving.
8/13
Page 9
OPERATION OF THE APPLIANCE
1. Salamander is used in kitchens of restaurants, fast food stands, canteens, hospitals in
order to fry, grill or roasting of food.
2. Before initial use of the appliance, the outer surface should be wiped with a cloth soaked in warm water and soap.
NOTE: Do not use except purpose of use. The appliance should be operated by
qualified personnel knowing safety terms and technical specifications and who
has read the instruction manual.
CAUTION !
NEVER OPERATE YOUR appliance
WITHOUT GROUND CONNECTION.
Take the Salamander carefully out of its package.
Turn the starter switch step by step to set relevant operating temperature. Green lamp will light.
You may smell a fume and odor during first ever operation of the appliance. This smell will due to the first operation of the appliance and will diminish after a while.
The heaters are located in the top moving component. This top component moves up and down very easily. Its height is adjustable.
Food to be fried should be placed on the grill. Food to be cooked on tray should be
placed on oil pan.
. Dishes or trays to be used for serving fried foods should stand, up to maximum
572°F.Dishes and trays that could melt should not placed into the device.
After frying is completed, dishes or trays should be handled with gloves, when taking
them out.
Turn the commutator to 0position after daily use.
Disconnect the appliance from the power supply. Clean up the appliance after disconnecting it from the power supply.
It is recommended to operate the appliance between temperatures of
+41ºF +104ºF and in ambient humidity of maximum 65%.
10/13
Page 10
OPERATION OF THE APPLIANCE
CAUTION! : The appliances should be installed and
operated as described in this user’s manual. If any
failure is encountered please contact our nearest
authorized service dealer.
WHEN THE appliances HAS A FAILURE ONLY
AUTHORIZED MVP GROUP CORP. SERVICE DEALERS
ARE ALLOWED TO HANDLE THE APPLIANCES. IF
ANY PERSON OTHER THAN ONLY AUTHORIZED
SERVICE DEALERS HANDLE THE APPLIANCES, IT
WILL NOT BE COVERED BY THE WARRANTY.
NEVER ALLOW PEOPLE WHO ARE NOT AUTHORIZED
TO HANDLE THE APPLIANCE. OTHERWISE MVP
GROUP CORP WILL NOT BE RESPONSIBLE FOR THE
CONSEQUENCES. DURING MAINTENANCE SERVICE
OUR AUTHORIZED SERVICE DEALERS SHOULD NOT
BE PROPOSED TO USE NON-ORIGINAL SPARE
PARTS FOR WHATSOEVER. INSTALLING ANY NON-
ORIGINAL SPARE PART TO THE APPLIANCE
VOIDSTHE APPLIANCE OUT OF WARRANTY
COVERAGE.
11/13
Page 11
OPERATION OF THE APPLIANCE
CLEAN-UP AND MAINTENANCE
Clean-up and maintenance must be performed by the
operator
Before the power is switched on and after the first and
every subsequent use, the outer surface of the appliance
should be wiped clean with sponge and liquid detergent.
Do not use cleaning agents like hydrochloric acid or any
abrasive cleaning agents.
INFORMATION ABOUT OPERATIONAL FAILURE
FAILURES AND TROUBLESHOOTING:
If no heat is generated within the appliance, check the power supply or breaker for electrical current. If the appliance is connected to the power supply, the
reason may be that the on-off switch is not turned
on. If the appliance still
does not operate, please call our customer service
department at:
1-514-737-9701 or contact us by e-mail at:
service@mvpgroupcorp.com
11/12
Page 12
MANUFACTURERS LIMITED WARRANTY
MVP Group Corporation (MVP), hereby warrants all new equipment bearing the
name “AXIS” and installed within the continental United States of America or
Canada to be free from defects in material and workmanship, under normal and
regular usage and operation, for a period of one (1) year following the date of original
installation; or to a maximum of eighteen (18) months from factory date of shipment.
If a defect in material(s) or workmanship is detected; or found to exist within the stated
period above, MVP, at its sole discretion, shall either repair or replace any original
equipment manufacturers part which has proven to fail within the machine; providing
that the equipment has not been altered or tampered with in any form or manner
whatsoever, has been installed correctly as per the users manual, and
maintained and operated in complete accordance with this manual.
The labor cost (in terms of bench warranty) to repair or replace any part proven to be
defective, as per above clause(s), shall be covered by MVP, within the continental
United States of America or Canada; provided that prior authorization for this labor
was approved by MVP, the service work was performed by an authorized MVP service
agency; and that this agency installed an original and a genuine AXIS part in
the machine. Any repair work performed by a non-authorized service depot remains
the sole responsibility of the user, and thus MVP cannot be held responsible. The
installation of any generic part will not be valid; and therefore will void
this warranty. All authorized labor coverage shall be limited to bench rates only. Any
supplemental hourly rates or charges, such as transport, weekends or
emergency premiums remain the sole responsibility of the user.
Any charges exceeding those stated herein must have prior authorization by MVP.
Exceptions to above warranty are: (A) Damages resulting from shipping,
handling or abuse (B) Incorrect installation and/or connections (C) Adjustments or
calibration of any parts (D) Faults due to lack of regular maintenance or cleaning of
any internal part(s) (E) Replacement of any wearable items such as
accessories (F) Discoloration of any components due to chemical reaction
MVP GROUP CORP. STATES THAT THERE ARE NO OTHER WARRANTIES,
EXPRESSED OR IMPLIED, THAT ARE NOT SET FORTH HEREIN. MVP
GROUP CORP. SHALL ASSUME NO OTHER RESPONSIBILITY, EITHER DIRECT
OR NON-DIRECT, OR BE LIABLE FOR ANY OTHER OR ADDITIONAL LOSS
OR DAMAGE WHETHER BEING DIRECT OR CONSEQUENTIAL, AS A RESULT
OF ITS EQUIPMENT.
The manufacturer reserves the rights to alter design and specifications without notice
12/12
Page 13
Loading...