BASIC TURBINE FLOW METER (TW SERIES)
Technical Specifi cations
FLOW RANGES
5 - 50 GPM (gal/min)
40 - 400 GPM
PRESSURE
Working pressure up to 5,000 psi
ACCURACY
± 1% of reading or better
REPEATABILITY
± 0.1%
TEMPERATURE
Fluid temperature of -150° to 325°F
FILTRATION
300 microns
FLOW TURBINES
from AW-Lake Company
END CONNECTIONS
NPT
MATERIALS OF CONSTRUCTION
• Body & Flow Straightener: 316 Stainless Steel
• Rotor: Stainless Steel
• Rotor Shaft: Tungsten Carbide
• Rotor Support: 316 Stainless Steel
Benefi ts
ACCURATE & RELIABLE
The TW Series turbine meter is accurate to ±1% of
reading with repeatability of better than ±0.1%.
RUGGED AND COST-EFFECTIVE
All stainless steel construction and tight machining
tolerances make for excellent durability/long life.
INDUSTRY STANDARD
This fl ow meter comes with a standard NPT end
connections for universal applications.
VERSATILE
The meter or just the meter internals are perfect
drop-in replacements for NuFlo/Haliburton and
Blancett turbine fl ow meters.
ELECTRONIC INTEGRATION
This meter can accept a variety of existing
electronics, such as the MCII, MCIII and BL2800.
SIMPLIFIED MAINTENANCE
Maintenance is easy with the rotor replacement
kit. Rotor can be replaced in just 2-3 minutes.
© 2009 AW-Lake Company All rights reserved. Rev. 3/4/10 SBTWDATA-509 MWR
BASIC TURBINE FLOW METER (TW SERIES)
Meter Specifi cations
FLOW TURBINES
from AW-Lake Company
Part
Number
TW-100-x 5-50 900 1” Male NPT 300 5,000 4” / 102 mm TW-KIT-100
TW-200-x 40-400 45 2” Female NPT 300 5,000 10” / 254 mm TW-KIT-200
* x=1 for 1 pickup collar, x=2 for 2 pickup collars
** K-Factors given are averaged. A calibration sheet accompanies every meter sold.
*** Repair Kits include retaining rings, fl ow straightener and rotor assembly.
Range
(gal/min)
K-Factor *
(Pulses/ gal)
Porting Filtration
(micron)
Pressure
Rating (psi)
End to End
Length
Repair Kit **
Part Number
Meter Dimensions
1″ NPT
1″ NPT (M)
Ports
2.73″
1.86″
Turbine Flow Meter with 1” Connections
4″
1″ NPT
2″ NPT (F)
2″ NPT (F)
Ports
Ports
4″
3.965″
3.2″
10″
Turbine Flow Meter with 2” Connections
Sensor Options*
Model Sensor Type Temp (ºF)
MG-300 Magnetic Pick-up -150 to 325
JV-400 Meter Mounted Amplifi er -40 to 185
FIP-4TS 4-20 mA output -40 to 300
Meter Mounted Displays:
TM-8A no output 0 to 140
TM-8B 2 pulse output 0 to 140
TM-8C 4-20mA and pulse outputs 0 to 140
* For additional sensors available, contact factory.
© 2009 AW-Lake Company All rights reserved. Rev. 3/4/10 SBTWDATA-509 MWR
Contact Sabre Turbine Meters:
toll-free: 800-850-6110
fax: 262-884-9810
email: sabreinfo@aw-lake.com