Technical Specifi cations
FLOW RANGES 5 - 50 GPM (gal/min)
40 - 400 GPM
PRESSURE Working pressure up to 5,000 psi
ACCURACY ± 1% of reading or better
REPEATABILITY ± 0.1%
TEMPERATURE Fluid temperature of -150° to 325°F
FILTRATION 300 microns
FLOW TURBINES
from AW-Lake Company
END CONNECTIONS NPT
MATERIALS OF CONSTRUCTION
• Body & Flow Straightener: 316 Stainless Steel
• Rotor: Stainless Steel
• Rotor Shaft: Tungsten Carbide
• Rotor Support: 316 Stainless Steel
Benefi ts
ACCURATE & RELIABLE
The TW Series turbine meter is accurate to ±1% of reading with repeatability of better than ±0.1%.
RUGGED AND COST-EFFECTIVE
All stainless steel construction and tight machining tolerances make for excellent durability/long life.
INDUSTRY STANDARD
This fl ow meter comes with a standard NPT end connections for universal applications.
VERSATILE
The meter or just the meter internals are perfect drop-in replacements for NuFlo/Haliburton and Blancett turbine fl ow meters.
ELECTRONIC INTEGRATION
This meter can accept a variety of existing electronics, such as the MCII, MCIII and BL2800.
SIMPLIFIED MAINTENANCE
Maintenance is easy with the rotor replacement kit. Rotor can be replaced in just 2-3 minutes.
© 2009 AW-Lake Company All rights reserved. Rev. 3/4/10 SBTWDATA-509 MWR
Page 2
BASIC TURBINE FLOW METER (TW SERIES)
Meter Specifi cations
FLOW TURBINES
from AW-Lake Company
Part Number
TW-100-x 5-50 900 1” Male NPT 300 5,000 4” / 102 mm TW-KIT-100 TW-200-x 40-400 45 2” Female NPT 300 5,000 10” / 254 mm TW-KIT-200
* x=1 for 1 pickup collar, x=2 for 2 pickup collars ** K-Factors given are averaged. A calibration sheet accompanies every meter sold. *** Repair Kits include retaining rings, fl ow straightener and rotor assembly.
Range (gal/min)
K-Factor * (Pulses/ gal)
Porting Filtration
(micron)
Pressure Rating (psi)
End to End Length
Repair Kit ** Part Number
Meter Dimensions
1″ NPT
1″ NPT (M) Ports
2.73″
1.86″
Turbine Flow Meter with 1” Connections
4″
1″ NPT
2″ NPT (F)
2″ NPT (F)
Ports
Ports
4″
3.965″
3.2″
10″
Turbine Flow Meter with 2” Connections
Sensor Options*
Model Sensor Type Temp (ºF)
MG-300 Magnetic Pick-up -150 to 325 JV-400 Meter Mounted Amplifi er -40 to 185 FIP-4TS 4-20 mA output -40 to 300
Meter Mounted Displays:
TM-8A no output 0 to 140 TM-8B 2 pulse output 0 to 140 TM-8C 4-20mA and pulse outputs 0 to 140
* For additional sensors available, contact factory.
© 2009 AW-Lake Company All rights reserved. Rev. 3/4/10 SBTWDATA-509 MWR
Contact Sabre Turbine Meters: