SANITARY TURBINE FLOW METER - TA3 SERIES
TECHNICAL SPECIFICATIONS
BENEFITS
Durable & Cost Effective
This meter’s rugged 316 stainless steel
construction provides a durable and
economic flow metering solution to sanitary
environments.
Measuring Accuracy
± 1.0% of reading or better
(±1% of reading over the upper 70% of the measuring
range for 3/8, 1/2 and 3/4 in. meters)
Repeatability
± 0.1%
Flow Measuring Range
0.6 to 400 GPM (gal/min)
Turn Down Ratio
10:1
* Depends on connecon size & clamp. Note: .COP (Clean-Out-of-Place) **Sensor & seal dependent.
Maximum Operating Pressure
Working pressure up to 1,000 psi
Temperature Range
Fluid temperature up to 300°F
**
Electrical Connection
NEMA 6 Connector
Port Connection
Tri-clamp
MATERIALS OF CONSTRUCTION
Body & Rotor Support 316L Stainless Steel
Rotor Nickel Plated Stainless Steel
Bearings Nickel Bindery Tungsten Carbide
*
Excellent Accuracy
The TA3 sanitary turbine flow meter can
achieve a flow accuracy up to 1.0% of reading
and is repeatable up to 0.1%.
Federal Compliance
The most up-to-date polishing technology is
utilized during manufacturing on all internal
components. and all TA3 models are 3A
authorized.
Flexible
This meter is available in nine different flow
ranges, covering flows from 0.6 GPM up to
400 GPM.
Versatile
This flow meter provides local flow rate and
volume totalization and will interface with most
displays, controllers and computers.
COMPANY
ELECTRONICS*
Model Sensor Type
RT-10R Baery-Powered Monitor 0 to 140
RT-30SD 15-24 VDC Powered Monitor 0 to 140
MAG-INVA Amplied Pulse Output 0 to 140
MG-300 Non-Amplied (external amplifer needed) 0 to 300
MG-450 Non-Amplied (external amplifer needed) 0 to 450
*Contact factory for addional sensor opons.
2440 W. Corporate Preserve Dr. #600, Oak Creek, WI 53154 | www.aw-lake.com
©2016 AW-Lake Company. All rights reserved. Doc ID: SANITDS16 Rev. 01.21.19
Temp (°F)
SANITARY TURBINE FLOW METER - TA3 SERIES
METER SPECIFICATIONS
Part
Number
Range
(gal/min)
K-Factor *
(Pulses/ gal)
Meter
Size
Clamp Size Weight
TA3-75-375-1 0.6 to 3 20,000 3/8” 3/4” 1
TA3-75-500-1 0.75 to 7.5 13,000 1/2” 3/4” 1
TA3-75-750-1 2 to 15 2,750 1/2” 3/4” 1
TA3-150-500-1 0.75 to 7.5 13,000 1/2” 1-1/2” 3
TA3-150-750-1 2 to 15 2,750 1/2” 1-1/2” 3
TA3-150-875-1 3 to 30 2,600 7/8” 1-1/2” 3
TA3-150-100-1 5 to 50 870 1” 1-1/2” 3
TA3-150-150-1 15 to 180 330 1-1/2” 1-1/2” 5.5
TA3-250-200-1 40 to 400 50 2” 2-1/2” 8.5
* K-Factors given are averaged. A calibraon sheet accompanies every meter sold.
METER DIMENSIONS
Part
Number
TA3-75-375-1 3″ 1.5″ 1″
TA3-75-500-1 3″ 1.5″ 1″
TA3-75-750-1 3″ 1.5″ 1″
TA3-150-500-1 4″ 2.0″ 2″
TA3-150-750-1 4″ 2.0″ 2″
TA3-150-875-1 4″ 2.0″ 2″
TA3-150-100-1 4″ 2.0″ 2″
TA3-150-150-1 6.25″ 2.3″ 2″
TA3-250-200-1 6.5″ 2.3″ 3″
A B C