AW-Lake RT-Ex15 Data sheet

8809 Industrial Drive, Franksville, WI 53126 Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
RT-Ex15
Meter Mounted Flow Monitor
with HART Communication Protocol
Technical Specifications:
· Digital meter mounted flow monitor · HART communication protocol
· Flow rate / total screens · Test Point for external frequency input
· Gate time function · Magnetically select any key functions
What is a RT-Ex15 meter mounted flow monitor?
The RT-Ex15 is a meter mounted digital flow monitor housed in a Class I Hazardous Location rated enclosure that features HART communication protocol. A large, back-lighted LCD graphic display provides an easy to read indication of flow rate or total in user programmable engineering units. To change any key functions, simply use the magnet that is attached. No opening of the enclosure is required. To prevent the magnet from entering the programming mode inadvertently, an on board jumper controls ability to allow programming via external magnet. An isolated input also allows for remote reset of the totalizer. Programmable opto­isolated open-collector outputs provide flow rate limit indication or a pulsed total output for remote monitoring and recording of totals. A 4-20 mA rate output with user programmable filtering and scaling is also provided for remote indication.
Rev 02/07
8809 Industrial Drive, Franksville, WI 53126 Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
Rev. 02/07
Products may be subject to change without notice – Contact factory for current information
Power Requirement:
15-24 VDC/150mA. (customer supplied)
Analog Output 4-20 mA:
16-bit D/A Converter 3 wire or 2 wire plus seperate supply Max. Load Impedance: 500 ohm.
Enclosure Certifications:
Class I, Groups A, B, C, D NEMA 4X Class II, Groups E, F, G FM Class No. 3615 Class III FM & CSA approval pending Atex: EEx d IIC, IP68 Copper Free Standards
Sensor/Monitor Frequency Range:
0-4000 Hz
Temperature Ratings:
-20 to 60ºC (-4 to 140ºF) Ambient
Connection:
¾" NPT Conduit Provisions
Two Opto-Isolated Open-Collector Outputs:
5-30 VDC Rating, 50 mA Max. (Minimum Load Impedance Required, 600 Ohm @ 30 VDC)
Opto-Isolated Reset Input:
5-30 VDC Input, 3.3Kohm Impedance
Monitor T
echnical Data
RT-Ex15 Part
Number
Option
RT-Ex15A Standard Unit
RT-Ex15B Infrared (JVK Only)
RT-Ex15C High-Temperature Pick-up
RT-Ex15D TR Nose (Turbine Only)
Part Number Configuration
NOTE: All RT-Ex15 meter mounted flow meters
are available with HART communication protocol. Contact the factory for HART communications protocol part availablility and part numbering information.
RT-Ex15
Meter Mounted Flow Monitor
with HART communication protocol