RT-Ex10 FLOW MONITOR
Introduction / Features/ Options…..……………………….... page 2
Ordering Information……..…………………………. page 2 Standard Configurations……..……………………… page 2
Dimensional Drawing.….……………………….…………. . page 3
Specifications…..………..…………………………..…....... . page 3
Wiring Connections (loop-powered output models only)..…. page 4
Fiber-optic Systems (fiber-optic input or output models only) page 4
RT-Ex10 Operation………………….....…..………………. . page 5
RT-Ex10 Display Modes………………….....…..………….. page 5
SLEEP Display ……………………...……… page 5
LO BAT Display ……………………….…… page 5
RATE Display Mode...............………………………. page 6
TOTAL Display Modes.....…………………..………. page 6
TOTAL Display…….……….…….…………. page 6
TOTAL Reset…….….…….……….. .. page 6
GRAND TOTAL Display………....……….. .. page 7
GRAND TOTAL Reset…….………... page 7
CLOCK Display Mode …………………...…………. page 8
Programming the RT-Ex10…….................…………………. page 8
TOTAL Mode Programming………………..………. page 9
K-Factor in Pulses Per Eng’g Unit………….. page 9
RATE Mode Programming….......................………. . page 10
TIME BASE for Rate.......…………….…….. page 10
GATE TIME…....….…..……………………. page 10
ANALOG SCALING (analog out models only) page 11
FREQ. SCALING (fiber-optic output models). page 12
CLOCK Mode Programming ……………………..…. page 13
SETTING THE TIME.………………..……… page 13
SLEEP TIMER….....…..……………………... page 13
Changing The Battery ………………………….…….………. page 14
Battery Replacement……………….…………………. page 14 Resetting the Battery Timer……...…………………… page 14
1
AW Company 8809 Industrial Drive, Franksville, WI 53126 à web: www.awcompany.com
Tel: 262-884-9800  Fax: 262-884-9810 | Email: aw@awcompany.com
RT-Ex10 manual 100606.doc Revision 100606
2
Introduction / Features / Options
The RT-Ex10 is a meter-mounted battery powered digital flow monitor. A large, six segment LCD display provides easy to read indication of flow rate and totals in any engineering unit. Programming, display mode selection, or totalizer reset is accomplished using an attached magnet without opening the enclosure or using the pushbuttons on the faceplate with cover off. Options include a loop-powered 4-20 mA rate output, fiber-optic input, and a scaled fiber­optic frequency output. A variety of sensor options are available to make the RT-Ex10 compatible with most AW Company flowmeters.
Ordering Information:
Part #
Std Sensor
Fiber Optic Input
Hub Sensor
TR Sensor
Battery Power
4-20mA Loop Powered Output
Fiber Optic Output
RT-EX10A RT-EX10C RT-EX10H RT-EX10D RT-EX10F RT-EX10L RT-EX10J RT-EX10N RT-EX10P RT-EX10R RT-EX10T RT-EX10U
X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X
Standard Configurations:
RT-EX10
SR# RT001500
SWIVEL FITTING
MAG SENSOR FOR TR SERIES TURBINES
5/64" HEX KEY
RT-EX10
SR# RT001500
HUB ADAPTOR
SPRING LOADED SENSOR NOSE
RT-EX10
SR# RT001500
FOP Fiber-optic Input/OutputHUBTR SeriesJV, HPM & TRG
RT-EX10
SR# RT001500
FIBER-OPTIC INPUT FROM FOP-20 OR FOP-30
X
FIBER-OPTIC OUTPUT TO OPTV-20
AW Company 8809 Industrial Drive, Franksville, WI 53126 à web: www.awcompany.com
Tel: 262-884-9800  Fax: 262-884-9810 | Email: aw@awcompany.com
RT-Ex10 manual 100606.doc Revision 100606
Ø.3 in.
5 in.
4.5 in.
RT-EX10
SR# RT001500
RT-Ex10 Dimensions
MAGNET WAND FOR PROGRAMMING/ DISPLAY SELECTION
Specifications
3
5 in.
5 in.
2.3 in.
Flowmeter Compatibility:
Positive Displacement: JV & HPM Series*
*(except JV-01, JV-10, & JV-12)
Turbine: TR, TRG & TA Series
(Linear flow range may vary)
Power:
Internal 3.6V “C” Cell Battery – field replaceable Four Year Battery – estimated average life
depending on RT-Ex10 model.
Sensor/Monitor Frequency Range:
0-3,000 Hz
Fiber-Optic Frequency Output (Option):
0-100 Hz Programmable Scaling
Temperature Ratings:
-20 to 70ºC (-4 to 158ºF) Ambient 80ºC (175ºF) Max. Fluid Temp.
2-Wire Loop Powered 4-20 mA Output (Option):
Loop power: 12-24 Vdc ±10%, Max. load: 250 Ohm @ 12V, 500 Ohm @ 24V
Enclosure Certifications:
Class I, Groups B, C, D Class II, Groups E, F, G Class III
Atex: EExd IIC, IP68
NEMA 4X, FM Class No. 3615 CSA Class 1, Div. 1 Certification Pending
AW Company 8809 Industrial Drive, Franksville, WI 53126 à web: www.awcompany.com
Tel: 262-884-9800  Fax: 262-884-9810 | Email: aw@awcompany.com
RT-Ex10 manual 100606.doc Revision 100606
4
Customer Connections
Loop-Powered Analog Output (loop-powered analog output models only)
A two-wire loop powered 4-20 mA output option is offered for the RT-Ex10. The analog Rate output has 16-bit resolution. Supply voltage can be between 12 and 24Vdc with maximum loads from 250 at 12Vdc to 500 at 24Vdc. The RT-Ex10 utilizes the output device AD421 manufactured by Analog Devices. The minimum output is trimmed to 4.00mA by the device manufacturer. Consult the manufacturer’s data sheet for AD421 for complete specifications regarding offset tolerance. The scaling value for the mA output is programmed from the Rate display screen. See ANALOG Scaling on page 11 for instructions on scaling of the analog output.
Wiring for the loop powered output option is via pig-tail leads with a 3/4” NPT wire exit for conduit connection. Connection to conduit is required to maintain the enclosures explosion-proof rating and must be made in accordance with all local and national electrical codes. MAKE CERTAIN CIRCUITS ARE NOT LIVE WHILE WIRING RT-Ex10 IN HAZARDOUS AREA. Keep cover tightly closed while circuits are alive.
RT-EX10
SR# RT001500
Fiber-Optic Systems (Fiber-optic input/output models only)
Fiber optic input models accept optical signals from AW Company FOP-20 or FOP-30 fiber optic transmitters using AW Company fiber optic cable. Fiber-optic output models will transmit a scaleable 0-100 Hz signal via fiber-optic cable to the AW Company OPTV-20 or OPTV-CM fiber optic receiver.
FOP Fiber-optic Input/Output
RT-EX10
SR# RT001500
PIGTAIL LEADS
(LABELLED)
mA +
mA -
1/2" NPT
OPTICAL RECEIVER GROUND - 8
mA +
LOOP-POWERED
TWO-WIRE 4-20 mA OUTPUT
mA -
SQUARE WAVE SIGNAL OUT - 7
+7-20 VDC - 1
COMMON - 2
FIBER-OPTIC CABLE
6 5 4 3
OPTV-20 OR OPTV-CM
FROM FOP-20 OR FOP-30
AW Company 8809 Industrial Drive, Franksville, WI 53126 à web: www.awcompany.com
Tel: 262-884-9800  Fax: 262-884-9810 | Email: aw@awcompany.com
OPTV OUTPUT
~1 ms*
FIBER-OPTIC CABLE
RT-Ex10 manual 100606.doc Revision 100606
PULSE TIME
FREQUENCY =
PULSE TIME
~1 ms*
* 6 ms FOR OPTV-CM
1
AMPLITUDE OUT: APPROX. SUPPLY VOLTAGE, DEPENDS ON LOAD
Loading...
+ 10 hidden pages