AW-Lake RT-30 Specifications

RT-30SD - FLOW TRANSMITTER WITH LOCAL DISPLAY
Ideal for any industry or ow measurement application where a local rate and total display is required and in locations where equipment is exposed to the elements.
FEATURES
FEATURES:
• Available in single and dual access models
• Can be mounted directly on flow meter or in remote location
• HART® communication protocol option for remote monitoring and programming monitoring and programming
TECHNICAL SPECIFICATIONS
BENEFITS
Options for Remote Indication
The RT-30 has options for remote flow monitoring:
• Frequency pulse output (standard)
• 4-20mA, user scalable (standard)
• HART communication protocol (optional)
Easy Field Programming
Remote Mounting Available
The RT-30 can be mounted remotely when used in conjunction with any AW frequency output sensor.
Up and Running in Minutes
A quick setup procedure allows you to have the flow monitor working with just a few simple programming steps.
Flexiable Mounting
The RT-30 unit can be rotated 360° for optimal viewing from any angle. Options available to fit any AW Gear Meter or Turbine Meter.
Weather-Proof Enclosure
NEMA 4X enclosure provides environmental protection from moisture and debris.
Power Requirement
9-24 VDC / 200mA (customer supplied) Class 2
Analog Output 4-20mA
• PWM converter
• 3- or 2-wire plus separate supply
• Max load impedance 500 ohm
Frequency Output Three Opto-Isolated Open-
Collector Outputs:
• Programmable for frequency or limit outputs
• 5-30 VDC rating
• 40 mA max (min. load impedance required 600 Ohm @ 30 VDC)
PART NUMBER GUIDE
RT - 30SD -
Enclosure style: D = Dual access S = Single access T = Single access, 316 stainless steel
Sensor: 00 = None* (Remote Mount) 02 = HUB-40SD1-S5-H2 11 = MAG-PB 31 = CAPM-15 41 = MG-300 42 = MG-450 81 = IR-PB
* Requires external sensor
Built in 30 point Linearizer Sensor/Monitor Frequency
Range
0-4,500 Hz
Temperature Rating
-20 to 60°C (-4 to 140°F)
Connection
3/4” female NPT conduit provisions
One Opto-Isolated Input
9-24 VDC remote reset
Communication Protocol: “blank” = none H = Hart®
COMPANY
2440 W. Corporate Preserve Dr, #600, Oak Creek, WI 53134 | www.aw-lake.com
©2016 AW-Lake Company. All rights reserved. Doc ID:RT30SDDS16
RT-30SD - FLOW TRANSMITTER WITH LOCAL DISPLAY
Ideal for any industry or ow measurement application where a local rate and total display is required and in locations where equipment is exposed to the elements.
SINGLE ACCESS ENCLOSURE (SHOWN HERE WITH HUB-40 SENSOR)
5.00in
127mm
2.42in
61.50mm
7.66in
194.65mm
DUAL ACCESS ENCLOSURE (SHOWN HERE WITH HUB-40 SENSOR)
5.02in
127.52mm
7.71in
Products may be subject to change without noce - Contact factory for the most up-to-date product informaon.
7.99in
203.01mm
©2016 AW-Lake Company. All rights reserved. Doc ID:RT30SDDS16