AW-Lake MicroFlow Specifications

MICROFLOW - POSITIVE DISPLACEMENT GEAR METER
Ideal for ow measurement of low and medium viscosity uids (solvents, polyurethanes, oils and other non-abrasive uids) at very low ow rates, as in chemical injection.
APPLICATIONS
AW Gear Meters offers these spur gear positive displacement flow meters that are suitable for a variety of applications:
BENEFITS
Accurate & Reliable
This meter has the ability to maintain consistent accuracy despite changing viscosity conditions, with accuracy of +0.5% of reading or better. Low friction gears and bearings allow for accurate measurement of low viscosity fluids, down to 1cP (custom calibration recommended).
Chemical injection skids
Fuel & solvent measurement
Liquid seal bead dispensing
Cylinder position measurement
TECHNICAL SPECIFICATIONS
Measuring Accuracy
± 0.5% or better, 10:1, 30cP
Flow Measuring Range
0.0005 to 0.25 gal/min
Maximum Operating Pressure
5,000 psi
Maximum Fluid Temperature
Depends on sensor used, refer to sensor tech guide.
MATERIALS OF CONSTRUCTION
Body
Gear & Ball Bearings
O-Ring
Sha
RECOMMENDED SENSORS
Batching
Low flow applications to 2 cc/min (0.0005 gal/min)
Repeatability
± 0.1%
NPT Female Ports Bi-directional flow capability Certifications
ATEX approved, non-sparking, CSA Class 1, Div. 1
316 Stainless Steel Stainless Steel PTFE (other options available) 420 C Stainless Steel
Rugged Construction
This PD meter’s solid construction of 316 stainless steel body and stainless steel gears & bearings stand up to the most rugged environments.
Flexible
Meter may be used in applications requiring bi­directional flow.
Simple to Install & Use
Installation is easy because there is no need for straight run piping upstream or downstream of the flow meter.
Certified
Sensors are available with ATEX non-sparking or CSA Class I, Div. 1.
COMPANY
Model Sensor Type Sensor Features
EX Meters
HUB-40-Ex Hazardous area rated sensor CSA/CUS cered pulse output hall
eect single sensor
RT-30Ex Hazardous area rated ow
transmier
Non EX Meters
FIP-xx Meter mounted analog output
sensor
MAG-xx Hall eect single sensor Frequency output with conduit
RT-30SD Local ow rate transmier Rate & local display with 4-20mA
2440 W. Corporate Preserve Dr. #600, Oak Creek, WI 53154 | www.aw-lake.comawinfor
Rate & local display with 4-20mA analog output
3-wire analog output, current or voltage
connecon
analog output
©2016 AW-Lake Company. All rights reserved. Doc ID: MICRODS16
MICROFLOW - POSITIVE DISPLACEMENT GEAR METER
Ideal for ow measurement of low and medium viscosity uids (solvents, polyurethanes, oils and other non­abrasive uids) at very low ow rates, as in chemical injection.
METER DATA
Meter Type Range
(gal/min)
JVS-01UF-25-NPT .0005-.25 151,300 40 3.3 2.2 4 1/4”
JVS-01UF-25-NPT-EX.0005-.25 151,300 40 3.3 2.2 4 1/4”
Impulse/ gallon
Impulse/ ccDiameter
(inches)
Height (inches)
Weight (lbs)
Ports Filtraon
NPT
NPT
Pressure
(micron)
<10 5000
<10 5000
Rang (psi)
©2016 AW-Lake Company. All rights reserved. Doc ID: MICRODS16