HIGH PRESSURE TURBINE FLOW METER - HM SERIES
TECHNICAL SPECIFICATIONS
BENEFITS
Industry Standard
Standard end connections are AutoClave®,
(also available in Grayloc® and Techlok®.)
Measuring Accuracy
± 1.0% of reading or better
Repeatability
± 0.05%
Maximum Operating Pressure
Working pressure up to 20,000 psi
Maximum Operating Temperature
Depends on sensor used, refer to
sensor technical guide.
Flow Measuring Range
.08 to 32 GPM (gal/min)
Filtration Requirement
300 microns
Turn Down Ratio
10:1
End Connections
Medium pressure AutoClave
MATERIALS OF CONSTRUCTION
Body 1.3980 Stainless Steel
Rotor Support 316 Ti Stainless Steel
Rotor 329 Stainless Steel
Bearings/Sha Tungsten Carbide
High Pressure Suitable
The HM Series of turbine flow meters can
handle low viscosity fluids flowing under
extremely high pressures, such as hydraulic
and fuel systems and offshore chemical
injection systems.
Hazardous Area Approved Sensors
A complete line of hazardous area approved
sensors and displays are available for the HM
Series meters.
Durable & Cost-Effective
This meter’s rugged stainless steel construction
provides a durable and economic flow metering
solution to sanitary environments.
Explosion Proof (EX) Options Available
COMPANY
RECOMMENDED SENSORS
Model Sensor Type
RT-30EX Hazardous area rated local ow rate
transmier
HUB-40EX Hazardous area rated sensor -40 to 140
RT-30SD Local ow rate transmier -40 to 140
VTEK/P Pulse output sensor -40 to 248
VTEK/P-EX Intrinsic safe pulse output sensor -40 to 185
*For addional sensors such as extended temperature range, contact factory.
2440 W. Corporate Preserve Dr. #600, Oak Creek, WI 53154 | www.aw-lake.comawin-
*
EX Meters
-6 to 140
Non EX Meters
©2016 AW-Lake Company. All rights reserved. Doc ID: HMDS16
Temp (°F)
HIGH PRESSURE TURBINE FLOW METER - HM SERIES
METER SPECIFICATIONS
Part
Number
HM 003/TS-AC/xx (EX C) 0.08 to 0.4 9/16” 123,000 1,100 15,000
HM 004/TS-AC/xx (EX C) 0.13 to 1.05 9/16” 94,600 1,700 15,000
HM 005/TS-AC/xx (EX C) 0.2 to 1.6 3/4” 67,400 1,750 15,000
HM 006/TS-AC/xx (EX C) 0.3 to 2.6 3/4” 45,400 2,100 15,000
HM 007/TS-AC/xx (EX C) 0.5 to 5 1” 19,000 1,650 15,000
HM 009/TS-AC/xx (EX C) 0.9 to 9 1” 19,000 2,750 15,000
HM 011/TS-AC/xx (EX C) 1.6 to 16 1” 5,000 1,350 15,000
Range
(gal/min)
Medium Pressure
AutoClave
K-Factor*
(Pulses/ gal)
Frequency
(0-max. Hz)
Pressure
Rang (psi)
**
**
**
**
**
**
**
HM 013/TS-AC/xx (EX C) 2.25 to 22.5 1-1/2” 3,500 1,300 15,000
HM 017/TS-AC/xx (EX C) 3.2 to 32 1-1/2” 1,440 840 15,000
*
Average gures, exact gures can be taken from the calibraon record supplied with each ow meter. **20,000 psi if NOT used with RT-30EX or HUB-40EX. EX versions available.
METER DIMENSIONS
Part
Number
HM 003/TS-AC/xx EX C 3.54” 13/16” 1.97”
HM 004/TS-AC/xx EX C 3.54” 13/16” 1.97”
HM 005/TS-AC/xx EX C 4.13” 3/4” 1.97”
HM 006/TS-AC/xx EX C 4.13” 3/4” 1.97”
HM 007/TS-AC/xx EX C 5.31” 1-3/8” 1.97”
HM 009/TS-AC/xx EX C 5.31” 1-3/8” 1.97”
HM 011/TS-AC/xx EX C 5.51” 1-3/8” 1.97”
HM 013/TS-AC/xx EX C 6.89” 1-7/8” 2.76”
HM 017/TS-AC/xx EX C 7.01” 1-7/8” 2.76”
A B D
A
B
SAMPLE PART NUMBER
HM 003/TS-AC/xx EX C
xx = viscosity group. See table below.
VISCOSITY GROUPS
Turbine
Size
HM 003 1 - 9 CST 15
HM 003 10 - 30 C ST 57
HM 004 1 - 19 C ST 27
HM 004 20 - 30 C ST 77
HM 005 1 - 9 CST 15
HM 005 10 - 30 C ST 57
HM 006 1 - 19 C ST 27
HM 006 20 - 30 C ST 77
HM 007 1 - 19 C ST 27
HM 007 20 - 30 C ST 77
HM 009 1 - 9 CST 15
HM 009 10 - 19 C ST 52
HM 009 20 - 30 C ST 77
Viscosity
Viscosity
Group #
Turbine
Size
HM 011 1 - 9 CS T 15
HM 011 10 - 19 CST 52
HM 011 20 - 30 CST 77
HM 011 30 CST > 80
HM 013 1 - 7 CS T 10
HM 013 8 - 14 CST 40
HM 013 15 - 19 CST 65
HM 013 19 - 29 CST 75
HM 013 30 CST > 80
HM 017 1 - 7 CS T 10
HM 017 8 - 9 CS T 35
HM 017 10 - 29 CST 55
HM 017 30 CST > 80
Viscosity
Viscosity
Group #