8809 Industrial Drive, Franksville, WI 53126 Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
T
echnical Specifications:
· Two signal component ratio monitor · Seven totalizers for reporting
· RS-232 or RS-485 serial communication · Display flow rate, total or ratio
· Nine programmable units of measure · Net consumption display
What is an EMO-500 Monitor?
The EMO-500 is a two signal component ratio monitor designed for use in steady or pulsing
flow streams. Signals from two flow meters can be displayed as independant flow rates or
totals, or as an A/B, A + B or A - B relationship. In ratio mode, a programmable ideal ratio is
compared to the actual ratio, and off ratio conditions are indicated via one of the four limit
relays. These relays can be used to operate audible or visual alarms, or to terminate pump
operation. The EMO-500 has seven different totalizers for reporting and record keeping.
Other features include job resets, RS-232/485 Serial Communication and a 4-20 mA output.
EMO-500
Two Component Ratio Monitor
Rev. 05/04

8809 Industrial Drive, Franksville, WI 53126 Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
Key Programming Features:
Ideal Ratio: User defined, compared to actual ratio
Gate Time: Time before the flow rate display updates
Sample Size: Number of pulses counted before ratio updates
Limits: Ratio, Flow Rate and Total
Units of Measure: Liter, CC, Gal, Oz, gr, kg, Lb, RPM, Hz
Display Information:
Ratio: Ideal Flow Rate A Job Total A Grand Total
Ratio: Actual Flow Rate B Job Total B Grand Total B
Limit Settings Flow Rate A+B Job Total A+B Grand Total A+B
Limit Status Flow Rate A-B Job Total A-B
Technical Information:
Power Supply Input: 110 VAC or 220 VAC
Consumption: 4 Watts
Communication: Type: RS-232 & RS-485
Protocol Type Similar to OPTO 323
Environmental: Storage: -40° C to 85°C
Operating: 0° C to 50° C
Humidity: 10 to 90% Noncondensing
Limits: 10 Amp, 110 V dry contact relays
EMO-500 –
Two Component Ratio Monitor
Rev 05/04
Products may be subject to change without notice – Contact factory for current information
E-MON-503
PC Based Material Monitoring System
EMO-500/E Industrial Enclosure
Dual Flow Meter Support
Warning and Alarm Lights
Alarm Siren and Silencer
External Reset
RS-232/485 Communications
NEMA 12 Enclosure
Industrial Push Button Control
Pre-wired, ready to go