CAPM-2N Carrier Frequency Pickup Module
Description:
The CAPM-2N is used with the HPM series and the TR series of flow meters. The CAPM-2N is a Carrier Frequency sensor which means there is no permanent magnet in the pickup and any magnetic drag on the flow meter gears or turbine is avoided. The CAPM-2N requires a supply voltage between 10 Volt DC to 30 Volt DC. A diode in the supply input prevents damage to the module in case the polarity of the supply voltage is wrong. The output signal is a square wave. The frequency is proportional to the flow rate.
The output is a sinking open collector NPT transistor.
Technical Data :
Supply Voltage : 10 to 30 Volt DC Supply Current : 9 mA @ 15 Volt, Max 18mA Minimum Signal : 0.5 Hz Duty Cycle : 50% Frequency Output : Flow dependent, up to 2000 Hz Sinking Capacity: 50 mA Max
Connections:
A - +10 to 30 Volt DC supply voltage B - Ground for supply and signals C - Frequency signal output
AW Company wire color code:
Supply Voltage: Red Ground: Black Signal: White
2440 W. Corporate Preserve Dr. #600, Oak Creek, WI 53154 | www.aw-lake.com | Rev. 07/2017