MAG-EX Hall Effect Pickup
Installation and Technical Data Guide
AW Gear Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: aw@aw-lake.com www.awgearmeters.com
Rev 08/12
Description:
The MAG-J is a Hall Effect sensor which is compatible with all AW and KEM Positive Displacement gear flow
meters except ZHM-04 to the ZHM-07KL. The sensor detects the rotation of the flow meter’s gears and emits
a frequency signal proportional to flow. The output signal is a square wave pulse which has a duty cycle of
approximately 50%.
MAG-J signal outputs are protected with a self-resetting fuse. This fuse has a 50mA nominal trip point. When
a trip occurs, turn off power to the sensor and remove output load to reset fuse.
The MAG-J sensor has two different output configurations: MAG-J-PA for a sinking output and MAG-J-PB for a
sourcing output.
Installation:
• Ensure that the flowmeter sensor cavity is free of debris prior to installing pickup
• Swivel fitting is required for sensor mounting
• 4 Steps to properly install sensor:
1- Securely fasten swivel fitting on flow meter
2- Turn set screws counter clockwise until they are not visible inside the swivel fitting
3- Install sensor into swivel fitting until sensor bottoms out in the sensor hole
4- Tighten set screws by turning clockwise
NOTE: DO NOT OVER TIGHTEN SET SCREWS OR SENSOR DAMAGE WILL OCCUR!
NOTE: WIRING SHOULD BE INSTALLED BY A QUALIFIED INSTRUMENTATION TECHNICIAN
MAG-J-PA MAG-J-PB Wire Color
Output Output White
Ground Ground Black
Supply Supply Red
AW Gear Meters wiring color code:
Part number configuration:
MAG-J sensors can be used with all AW and KEM
Positive Displacment great flow meters except
ZHM-04 to the ZHM-07KL
MAG-J-PA for a sinking output
MAG-J-PB for a sourcing output
Note: In order to recieve correct swivel fitting with your sensor - you
must specify meter part number when ordering
MAG-EX Hall Effect Pickup
Installation and Technical Data Guide
AW Gear Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: aw@aw-lake.com www.awgearmeters.com
Rev 08/12
MAG-J-PA Sinking Output Circuit
MAG-J-PB Sourcing Output Circuit
• User may need to add external components to interface to displays
or other instruments
• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA
• Signal output square wave :
V
high
= Supply -1V @ no output load
V
low
= 0.1V
• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA
Supply Voltage: +10 to 28 Volt DC
Supply Current: 8 mA @ 12 VDC, 12mA @ 24 VDC
Duty Signal: 50% ± 15%
Minimum Signal: 0.5 Hz
Frequency Output: Flow dependent, up to 2,000 Hz
Driving Capacity: 50 mA Max resistive load
Output Impedance: ~ 40 Ohm - analog switch and self-resetting fuse
Temperature Range: -40° F to 185° F (-40° C to 85° C)
Technical Data: