AW Gear Meters IR-P User Manual

IR-P
Infrared Optical Sensor
FOR CLEAR FLUIDS ONLY
Installation and Technical Data Guide
AW Flow Meters 8809 Industrial Drive, Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
Rev 09/05
Description:
IR-P signal outputs are protected with a self-resetting fuse. This fuse has a 50mAnominal trip point. When a trip occurs, turn off power to the sensor and remove output load to reset fuse.
The IR-P sensor’s output configuration is: IR-PAfor a sinking output, IR-PB for a sourcing output.
Installation:
• Ensure that the flowmeter sensor cavity is free of debris prior to installing pickup
• Amounting bracket is required for sensor mounting
• 4 Steps to properly install sensor: 1- Securely fasten mounting bracket on flow meter 2- Turn set screws counter clockwise until they are not visible inside the mounting bracket 3- Install sensor into mounting bracket until sensor bottoms out in the sensor hole 4- Tighten set screws by turning clockwise
NOTE: DO NOT OVER TIGHTEN SET SCREWS OR SENSOR DAMAGE WILL OCCUR!
NOTE: WIRING SHOULD BE INSTALLED BY A QUALIFIED INSTRUMENTATION TECHNICIAN
IR-PA IR-PB Wire Color
NC NC Green
Output Output White
Ground Ground Black
Supply Supply Red
AW Flow Meters Wiring Color Code:
Part number configuration:
IR-P sensors can be used with all AW Flow Meters JVK Positive Displacement gear flow meters only.
IR-PA for a sinking output, IR-PB for a sourcing output
Note: In order to recieve correct mounting bracket with your sensor ­you must specify meter part number when ordering
IR-P Infrared Optical Sensor
FOR CLEAR FLUIDS ONLY
Installation and Technical Data Guide
AW Flow Meters 8809 Industrial Drive, Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
Rev 09/05
IR-P
A Sinking Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog Switch
• User may need to add external components to interface to displays or other instruments
• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA
Supply Voltage: +10 to 26 Volt DC Supply Current: 20 mA ± 0.10 Duty Signal: 50% ± 15% Minimum Signal: 0.5 Hz Frequency Output: TBD Driving Capacity: 50 mA Max resistive load Output Impedance: ~ 40 Ohm - analog switch and self-resetting fuse Temperature Range: -40° F to 185° F (-40° C to 85° C)
Technical Dat
a:
• Signal output square wave:
V
high
= Supply -1V @ no output load
V
low
= 0.1V
• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog Switch
IR-PB Sourcing Output Circuit