AW Gear Meters HEF User Manual

HEF Hall Effect Pickup
Installation and Technical Data Guide
AW Flow Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
Rev 06/06
Description:
The HEF is a Hall Effect sensor which is compatible with the Aluminum, 303 Stainless Steel and 316 Stainless Steel body JV-CG and JV-KG series of flow meters. The sensor detects the rotation of the flow meter’s gears and emits a frequency signal proportional to flow. The output signal is a square wave pulse which has a duty cycle of approximately 50%.
HEF signal outputs are protected with a self-resetting fuse. This fuse has a 50mA nominal trip point. When a trip occurs, turn off power to the sensor and remove output load to reset fuse.
The HEF sensor has two different output configurations: HEF-A or HEF-AA for a sinking output and HEF-B or HEF-BB for sourcing output.
Installation:
• Ensure that the flowmeter sensor cavity is free of debris prior to installing pickup
• Make sure the sensor mounting screws line up with the mounting holes. If they do not, remove and rotate the sensor 180°
NOTE: WIRING SHOULD BE INSTALLED BY A QUALIFIED INSTRUMENTATION TECHNICIAN
Pin Number Wire Color Supply Voltage: 6 Red Ground: 5 Black Signal: 4 White
AW wiring color code:
Pin Number HEF-A / -AA HEF-B / -BB
1 NC NC
2 NC NC
3 NC NC
4 Output Output
5 Ground Ground
6 Supply Supply
Electrical Connection for Pin Connector
1 3 5
6
1.19"
HEF-X: (2.12")
HEF-XX: (2.39")
Part number configuration:
HEF sensors can be used wih all Aluminum, 303 Stainless Steel and 316 Stainless Steel body flow meters
JV-CG 01, 10, 15, 20 & 30 JV-KG 12, 20 & 30
JV-60CG & JV-60KG ONLY
Pinout looking at male connector on sensor
HEF-A, HEF-B
HEF-AA, HEF-BB
HEF Hall Effect Pickup
Installation and Technical Data Guide
AW Flow Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awflowmeters.com
Rev 06/06
HEF-A / -AA Sinking Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog Switch
HEF-B / -BB Sourcing Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog Switch
• User may need to add external components to interface to displays or other instruments
• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA
• Signal output square wave :
V
high
= Supply -1V @ no output load
V
low
= 0.1V
• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA
Supply Voltage: +10 to 28 Volt DC
Supply Current: 8 mA @ 12 VDC, 12mA @ 24 VDC
Duty Signal: 50% ± 15%
Minimum Signal: 0.5 Hz
Frequency Output: Flow dependent, up to 2,000 Hz
Driving Capacity: 50 mA Max resistive load
Output Impedance: ~ 40 Ohm - analog switch and self-resetting fuse
Temperature Range: -40° F to 185° F (-40° C to 85° C)
Technical Dat
a: