AW Gear Meters DH-Dual User Manual

DH Dual Hall Effect Pickup
Installation and Technical Data Guide
AW Gear Meters Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awgearmeters.com
Rev 06/10
Description:
The DH Dual Hall Effect Pickups are microprocessor-based sensors for use with the JV-CG and JV-KG series of positive displacement flow meters. The DH sensors can detect both uni- and bi-directional flow. The sensors’ mode of operation is determined by an output selection switch located inside the housing. The DH detects the rotation of the flow meter’s gears and emits a frequency signal proportional to flow. The output signal is a square wave pulse which has a duty cycle of approximately 50%.
DH signal outputs are protected with a self-resetting fuse. This fuse has a 50mA nominal trip point. When a trip occurs, turn off power to the sensor and remove output load to reset fuse. The sensor has two different output configurations: sinking output and sourcing output.
The DH sensor circuit board is equipped with a red and green LED. The red LED is a status LED which, when the sensor is operating properly, will flash once every 2 seconds. The green LED indicates the pulse of the input signal. Note that signals above 20Hz will look as solid green.
Installation:
• Ensure that the flowmeter sensor cavity is free of debris prior to installing pickup
• Make sure the sensor mounting screws line up with the sensor mounting holes. If they do not, remove and rotate the sensor 180°
• Sensor is equipped with an output test feature for readouts before initial running of your system
TEST FEATURE:
Note: Power must be cycled for new setting to take effect
• Switch setting 8 will cause the pick-up to output a 10 Hz (+/- 20%) Phase = +90 deg pulse output, simulating
low flow conditions without flow through your meter.
• Switch setting 9 will cause the pick-up to output a 250 Hz (+/- 20%) Phase = -90 deg pulse output, simulat-
ing medium flow conditions without flow through your meter.
NOTE: WIRING SHOULD BE INSTALLED BY A QUALIFIED INSTRUMENTATION TECHNICIAN
Pin Number Wire Color Signal 2: 2 Green Signal 1: 4 White Ground: 5 Black
Supply Voltage: 6 Red
Wiring Color Code
Pin Number DH-A / -AA DH-B / -BB
1 NC NC 2 Output 2 Output 2 3 NC NC 4 Output 1 Output 1 5 Ground Ground
6 Supply Supply
Electrical Connection for Pin Connector
1 3 5
6
Pinout looking at male
connector on sensor
Switch Output 1 Output 2
0 Direction Signal 2 1 Signal 1 Signal 2 2 Direction Signal 1 + 2 (2x frequency) 3 Signal 1 Signal 1 + 2 (2x frequency) 4 Signal 1 (both outputs in phase) 5 Signal 2 (both outputs in phase) 6 Signal 1 + 2 (both 2x frequency & both outputs in phase) 7 Reserved 8 Test: S1 & S2 == 10 Hz (+/- 20%) Phase = +90 deg. 9 Test: S1 & S2 == 250 Hz (+/- 20%) Phase = -90 deg.
DH Operating Modes
Top view of circuit board with
view of LED’s and switch
Note: Power must be cycled for new
setting to take effect
DH Dual Hall Effect Pickup
Installation and Technical Data Guide
AW Gear Meters Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awgearmeters.com
Rev 06/10
DH-A
/ -AA Sinking Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog Switch
DH-B / -BB Sourcing Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog Switch
• User may need to add external components to interface to displays or other instruments
• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA
• Signal output square wave : V
high
= Supply -1V @ no output load
V
low
= 0.1V
• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA
Supply Voltage: +10 to 27 Volt DC Supply Current: 18 mA @ 12 VDC, 25 mA @ 24 VDC Duty Signal: 50% ± 15% Minimum Signal: 0.5 Hz Frequency Output: Flow dependent, up to 2,000 Hz Driving Capacity: 50 mAMax resistive load Output Impedance: ~ 40 Ohm - analog switch and self-resetting fuse Temperature Range: -40° F to 185° F (-40° C to 85° C)
Technical Data:
1.19"
DH-X: (2.12")
DH-XX: (2.39")
Part number configuration:
DH Sensors can be used with all Aluminum, 303 Stainless Steel and 316 Stainless Steel body flow meters
JV-CG 01, 10, 15, 20 & 30 JV-KG 12, 20 & 30
JV-60CG & JV-60KG ONLY
DH-A, DH-B
DH-AA, DH-BB