AW Gear Meters CAPM-15 User Manual

CAPM-15 High Temperature Pickup System
Wire Color Code:
Supply Voltage: Red Ground: Black Signal: White
The CAPM-15 High Temperature Pickup System consists of a CAPM-15/AMP signal amplifier module and the CP-30 high temperature carrier frequency pickup. The CAPM-15/AMP will work on a supply voltage between 10 Volt DC and 30 Volt DC. The module is protected against reversed polarity on the voltage supply. The length of wire between the CP-30 and the CAPM-15/AMP module should not be extended over 20 feet. The CP-30 is supplied with a 7-foot cable only.
Technical Data:
Supply Voltage .....: 10 to 30 Volt DC
Supply Current .....: 9 mA @ 15 Volt, max 18mA
Signal Output .......: Square wave, Supply minus 2-3 V, peak-to-peak
Frequency Output : Flow dependent, up to 2000 Hz Temperature range: CAPM-15/AMP : Up to 160°F/70°C
CP-30................: Up to 400°F/205°C
Connections:
1 - +10 to 30 Volt DC supply voltage 2 - Ground for supply and signals 3 - Not used 4 - Signal from pickup & shield wire 5 - Signal from pickup 6 - Not used 7 - Frequency signal output 8 - Not used
OUTPUT:
13V. peak-peak (4.2VRMS) @ 15V SUPPLY
Note: If signal does not go to ground, connect external resistor, 5 K-10 Kohm, between input and ground of monitoring equipment.
AW Gear Meters 8809 Industrial Drive, Franksville, WI 53126 web: www.awgearmeters.com
REV. 11/12 CAPM15.DOC
Tel: 262-884-9800 Fax: 262-884-9810 Email: awinfo@aw-lake.com