The contents of this document and the specifications of the products discussed herein are subject to change
without notice. Avigilon Corporation reserves the right to make any such changes without notice. Neither
Avigilon Corporation nor any of its affiliated companies: (1) guarantees the completeness or accuracy of the
information contained in this document; or (2) is responsible for your use of, or reliance on, the information.
Avigilon Corporation shall not be responsible for any losses or damages (including consequential damages)
caused by reliance on the information presented herein.
Avigilon Corporation
avigilon.com
PDF-4PortAnalytics-A
Revision: 3 - EN
20180920
This device is provided with a battery powered real-time clock circuit. There is a danger of explosion if battery is
incorrectly replaced. Replace only with same or equivalent type recommended by the manufacturer. Discard
used batteries according to the manufacturer's instructions.
This equipment is to be connected only to PoE networks without routing to the outside plant.
ii
Table of Contents
Introduction1
Overview1
Front View1
Rear View2
System Requirements2
Camera Frame Rate2
Web Browser2
Hardware Installation3
Supported Network Configurations4
Configuring the Avigilon Control Center™ Software5
Starting Up and Shutting Down the Avigilon Control Center Client Software5
Starting Up the Client Software5
Shutting Down the Client Software5
Logging Into and Out of a Site5
Logging In6
Logging Out6
Changing the Administrator Password6
Connecting Cameras to the Avigilon Control Center Software7
Setting the Recording Schedule8
Creating a Recording Template8
Setting Up a Weekly Recording Schedule9
Setting Data Aging9
Enabling Server Analytics11
Adding Users and Groups11
Adding Groups12
Adding Users13
Advanced Settings13
Configuring the Appliance15
Accessing the Web Interface15
Status15
Setup17
ACC17
Storage Management17
Network18
Users18
System19
iii
Setting the Date and Time19
Upgrading the Firmware19
Restarting the System20
Budgeting PoE Power20
Assigning a PoE Power Budget20
PoE Status22
Device Log22
Logging Out of the Web Interface23
Connecting to External Devices24
LEDIndicators25
Front Panel LEDs25
Back Panel LEDs25
Using the Reset Button26
Restarting the System26
Restoring Factory Default Settings26
Troubleshooting — Cannot Reach Default IP Address27
iv
Introduction
The Avigilon ACC ES Analytics Appliance is an all-in-one solution for network video recording plus server side
video analytics. The appliance features:
l A network switch to connect and power IP cameras.
l Built-in server to run the Avigilon Control Center Server Software.
l Video analytics engine to enable connected cameras to detect classified objects.
This guide describes how to configure the system after the appliance has been powered and is connected the
local area network.
Overview
Front View
1. Reset button
Use this button to physically restart the appliance or perform a factory reset.
2. Status LED
Provides information about daily operations. For more information, see LEDIndicators on page25.
Introduction1
Rear View
1. Corporate network uplink port
Accepts a 1GbE Ethernet connection to the general network to allow users access to the web interface
and connected camera video.
2. Camera network uplink port
Accepts a 1GbE Ethernet connection to the cameras that are connected to the PoE switch component.
Can be used to link to other PoE switches and cameras.
3. PoE switch component
Connect cameras to the 10/100 speed PoE switch component to power the cameras and record video.
4. Power connector
Accepts power to the appliance.
5.
I/O connector
Provides connections to external input/output devices. For more information, see Connecting to External
Devices on page24.
System Requirements
Camera Frame Rate
The ACC ES Analytics Appliance can provide analytics for non-analytics cameras. For optimal analytics
performance, the source camera should stream a minimum of 10 images per second (ips).
Web Browser
The ACC ES Analytics Appliance administration settings are managed through a web interface.
The web interface can be accessed from any Windows®, Mac or mobile device using any of the following web
browsers:
Rear View2
l Mozilla Firefox® browser version 3.6 or later
l Google Chrome™ browser 8.0 or later
l Microsoft Edge™ browser 25 or later
l Safari® 5.0 or later
l Chrome on Android™ 2.2 or later
l Safari on Apple® iOS 5 or later.
l Windows Internet Explorer® browser version 7.0 or later
NOTE: Your web browser must be configured to accept cookies or the web interface will not function correctly.
Hardware Installation
Complete the recommended procedure for installing the ACC ES Analytics Appliance:
1. Connect power and wait for the appliance to start up.
Do not connect any other cables until instructed in this procedure.
Thestatus LED turns green to indicate that the applianceis turned on.
2. Connect an Ethernet cable directly from a DHCP enabled port on your configuring laptop to the cameranetwork port on the appliance.
3. Open a web browser on the connected laptop and enter this IP address: https://169.254.100.100.
If you cannot reach the IP address, see Troubleshooting — Cannot Reach Default IP Address on page27.
4. When you are prompted by the web interface, enter a new password for the administrator username.
The page refreshes and you are prompted to log in.
5. Enter administrator as the username and your new password.
The Status page is displayed.
6. From the top of the page, select Setup.
7. On the ACC page, click Install ACC Client to download and install a copy of the Avigilon Control Center
(ACC) Client software to the connected laptop.
8. In the left panel, click Network.
9. On the Network page, assign a new hostname for the appliance and select how it obtains an IPaddress
from the corporate network and the camera network. For more information, see Network on page18.
10. Connect an Ethernet cable from the appliance to the corporate network.
11. Disconnect the configuring laptop from the appliance.
12. If required, mount the appliance on a wall using the supplied mounting brackets.
CAUTION — The appliance must be mounted as instructed or any issues that arise will not be
covered by the warranty.
Hardware Installation3
a. Attach the wall mount brackets to the lowest threaded holes on the sides of the appliance.
b. Position the appliance with the rear panel facing downwards.
c. Screw the wall mounting brackets to the wall.
13. Connect the cameras to the PoE switch component.
NOTE: Allow the appliance 1 to 2 minutes to budget power to all connected devices. The front camera
status LEDs initially show that PoE is provided to all connected devices, but the status may change if the
system detects that the total power consumption exceeds the PoE limits.
14. If required, connect other switches and cameras to the camera network.
Now, you can configure the appliance and cameras for daily operation through the Avigilon Control Center
Client software. For more information, see Configuring the Avigilon Control Center™ Software on page5.
Supported Network Configurations
NOTE: Camera Uplink Port does not support dynamically switching DHCP servers.
Network
Connections
Corporate LAN
Uplink only
Camera LAN
Uplink only
Corporate and
Camera
LAN Uplink
Camera Web
Interface
Access
No
Yes
via Camera
LAN Uplink
only
Supported IP Configurations
Corporate LAN
Uplink
Static or DHCP
assigned
Unconnected
(leave as DHCP)
Static, DHCPassigned, DHCPZeroconf
Camera LAN
Uplink
Unconnected
(leave as DHCP)
Static, DHCPassigned, DHCPZeroconf
Static, DHCPassigned, DHCPZeroconf
Notes
Camera LAN Uplink and
connected cameras will use
Zeroconf IP addresses.
Corporate and Camera LAN
Uplinks must be on different
subnets.
Supported Network Configurations4
Configuring the Avigilon Control Center™ Software
The ACC Client software allows you to view live and recorded video, monitor events, set up alarms, and control
user access to the system.
The ACC Client software is the application that you would use on a daily basis. It is also where most of the
system configurations are made.
This section includes the recommended steps for setting up your ACC system for the first time.
Starting Up and Shutting Down the Avigilon Control Center Client
Software
Starting Up the Client Software
Perform one of the following:
l In the Start menu, select All Programs or All Apps > Avigilon > Avigilon Control Center Client.
l
Double-clickordesktop shortcut icon.
l From the AvigilonControl Center Admin Tool, click Launch Control Center Client. For more information,
see the AvigilonControl Center Server User Guide.
When you are prompted, log in to your site. You can only access cameras and video after you log in.
Once the application has started, it will automatically display a list of all the sites that are connected to the same
network. You will be prompted to log in to all sites.
Shutting Down the Client Software
1.
In the top-right corner of the Client software, select> Exit.
2. When the confirmation dialog box appears, click Yes.
Logging Into and Out of a Site
After you start the ACC Client software, you are immediately asked to log in to a site. By default, the ACC ES
Analytics Appliance is automatically added to the system as a server within a site of the same name.
Configuring the Avigilon Control Center™ Software5
Logging In
1. Open the Site Login tab. The Site Login tab is automatically displayed if you are launching the Client
software for the first time.
To manually access the Site Login tab, do one of the following:
l
From the top-right corner of the window, select> Log In….
l
From the top-left corner of the application window, clickto open the New Task menu, then
click.
2. On the left side of the Site Login tab, select one or more sites.
If the site you want to log into is not shown, click Find Site… to discover the site.
3. Enter your username and password for the selected sites.
4. Click Log In.
You are logged into the selected sites.
If you want to be notified when new or disconnected sites come online, select the Notify me when additionalsites become available check box.
If you want to see the login page each time you launch the Client software, select the Show this tab on startup
check box. If you prefer not to login each time, you can disable this option and configure automatic login from
the Client Settings dialog box.
Logging Out
You can log out of one or all sites at any time.
To...Do this...
Log out of one or select sitesl In the System Explorer, select one or more sites then right-click and
select Log Out.
Log out of all sites
1.
In the top-right corner of the Client, select> Log Out.
2. In the confirmation dialog box, click Yes.
Changing the Administrator Password
After you log in to the ACC software for the first time, it is recommended that you change the default
administrator password.
Logging In6
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.