Avaya Visio-IP500 Instruction Sheet

Apply pressure at the bottom of the front panel.
Appuyez sur le bas du panneau avant. An der Vorderseite unten drücken. Aplicar la presión en el fondo del panel delantero. Aplique presión en el fondo del panel delantero.
Exerça pressão na parte inferior do painel frontal.
700503146 Issue 4 (2nd April 2012) Page 1 of 2
Avaya IP Office Unified Communications Module Instruction Sheet
Pull
under
the
front
edge.
Tirez le bord avant. An der unteren Kante herausziehen Tirare sotto al bordo anteriore. Tire de abajo del borde delantero.
Voorzichtig aan de voorkant uittrekken.
Puxe pela borda inferior.
The IP Office system must be shut down and then power to the IP Office system must be OFF during installation of all cards.
Shut Down, Power OFF
Le système IP Office doit être hors tension lors de l’installation de toutes les cartes. Während der Installation der Karte unbedingt jegliche Stromzufuhr ausschalten. Spegnere il sistema “IP Office” prima di installare le schede.
La fuente de alimentación al sistema “IP Office” debe estar apagada durante la instalación de todas las tarjetas.
A alimentação do sistema “IP Office” deve estar desligada durante a instalação de qualquer placa. Tijdens de installatie van de kaarten dient de voeding naar het “IP Office”-systeem uitgeschakeld te zijn.
Les précautions anti-statique doivent être respectées à tout moment. Unbedingt immer Antistatik-Vorsichtsmaßnahmen treffen. Proteggersi sempre dalle scariche elettrostatiche. Se deben seguir las precauciones contra la estática en todo momento.
Neem te allen tijde de antistatische voorschriften voor personen in acht.
É preciso observar sempre os cuidados de proteção antiestática.
Anti-Static precautions must be observed at all times.
Tools Required
Screwdriver
5mm Flathead
Outils nécessaires./Benötigtes Zubehör und Werkzeug/Utensili richiesti./ Herramientas requeridas/Ferramentas necessárias/Benodigd gereedschap.
Anti-Static Strap
Bracelet anti-statique/ Antistatisches Armband/ Fascetta antistatica/ Tira antiestática/ Pulseira antiestática/ Antistatisch riempje.
Battery Disposal
This is a Lithium coin cell battery. The battery can be removed from its holder by bending the tab out the way and then pulling the battery upwards.
The module includes a battery. If the module is no longer required, you must ensure that the battery is removed and disposed of correctly.
?
More Information
- IP Office Knowledge Base
- Avaya Support
For more information/Pour plus d'informations, voir/Weitere Informationen/Per ulteriori informazioni/ Para más información/Mais informações/Voor meer informatie.
http://marketingtools.avaya.com/knowledgebase http://support.avaya.com/
Web Browser Connection to the IP Office System
Web browser connection, either direct or via the customer’s LAN, to the LAN or WAN port on the system.
The Ethernet port on the front of the module is not used.
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
The source code .iso files for the Linux distribution used on this device are located in the /var/cache/ avaya folder on the device.
700503146 Issue 4 (2nd April 2012) Page 1 of 2
Avaya IP Office Unified Communications Module Instruction Sheet
Module Installation
1
Module Initialization
2
Anti-Static precautions must be observed at all times.
a
Remove Power
Any available slot can be used.
b
Remove a Slot Cover
Undo the retaining screw. Any available slot can be used.
Any unused
slot.
c
Insert the Module
During insertion check that the module has engaged with the slot rails.
Apply pressure at the
bottom of the front
panel.
d
Apply Pressure at the Base
Apply pressure at the base to engage with the card socket.
e
Secure the Module
Retighten the retaining screw.
f
Power On
Reconnect power to the system and switch on.
The Unified Communications Module is only supported in an IP500 V2 control unit, running IP Office Release 8.0 SP1 and only in systems with an IP Office Essential Edition license. These instructions assume that initial installation and configuration of the system has been completed.
a
Check the Module LEDs
Wait for the lower LED to become green with an amber blink every 5 seconds. This takes up to 2 minutes.
Lower LED =
Green On + Amber blink.
http://<IP Office LAN1 IP Address>:7070
b
Browse to the Module
Connection directly or via the customer’s LAN to the LAN or WAN port on the system. Do not use the port on the front of the module.
Lower Status LED
- Solid Red:Unpacking and initializing.
- Flashing Red:Module initialization.
- Flashing Green: OS initializing.
- Solid Green with Amber flash: OK.
- Off with Amber Flash: Card shutdown.
Upper LEDs 1 & 2
-Amber:BIOS Starting up.
Ethernet Port: Not used.
Buttons
- Upper Button: Module Shutdown/Startup.
- Lower Button: Not used.
USB Ports: Used for maintenance.
Module Summary
3
HDMI Port: Used for
maintenance.
c
Logon
When the logon menu is displayed, logon using the default name and password:
Release Pre-8.1
- Logon: webcontrol
- Password: web
d
Module Service Selection
Work through the menus to enable the module services.
Release 8.1+
- Logon:Administrator
- Password: Administrator
Loading...