Avaya Asynchronous Connectivity via CLAN User Manual

Asynchronous Connectivity via CLAN (TN799B) for DEFINITY® FEATURE: This feature will provide the capability for Services to access the switch via TCP/IP
using remote SAT (DSA). Remote Sat capability via TCP/IP will provide increase data speeds over existing speeds. System Application Limits : System Management G3r: 8 , G3si, csi : 5 , DEFINITY ONE® : N/A.
Purpose : This Job-Aid illustrates the capability to access DEFINITY®ECS via TCP/IP using BCMSVU R2V2 (and later) and DEFINITY SITE ADMINISTRATION (DSA).
SECURITY: Service requests by the client applications will be accepted on user administered IP addresses and TCP port numbers. In addition, the user will be able to specify explicit IP addresses that DEFINITY® ECS can accept client requests from.
Step : Description
1 : change system parameters maintenance page 2 of 3
§ Verify that Packet Intf1 and Intf2 are set to yes
§ See NOTE for Bus Bridge administration
2 : list configuration all to verify that CLAN board is present in example 1A07
3 : add data-module <ext>
§ Pick an extension from a list that was dedicated for the data-module.
§ The port type must be selected as Ethernet (depress the <HELP> key)
§ The Port will be the 17th port on the board location i.e.. 1A0717
§ The Link should be selected as : 1 (Range = 1-25)
§ The Name should be selected as CLAN
4 : Display port 1A0717
Verify that the Port information is administered correctly with the previous input
5 : list configuration board 1a07
Verify that port 17 on the CLAN board is now assigned
Step : Description
7 : Confirm DSA Computer and BCMSVU Server IP Address:
§ Click on Start / Run / CMD
§ At the DOS Prompt type : ipconfig /all | more
§ This will return your Computer Name (Node-Name) and IP Address.
§ For DSA and BCMSVU the IP Address should be static ( NOT DHCP).
8 : change node-names ip
§ add the node-name of the CLAN Board and IP Address
§ add the node-name of the DSA Computer and IP Address
§ add the node-name of the BCMSVU Server and IP Address
9 : change ip-interface
§ Enter the data required as shown .
§ Verify the Subnet Mask and Gateway Address (as provided by LAN/WAN
Administrator)
10 : change ip-services
§ Enter the data for the SAT as shown :
§ Service Type : SAT
§ Enabled : Y
§ Port : 5023
§ Local Node : CLAN
§ Remote Node : DSA Computer Node-Name
§ Remote Port : 0
11 : Verify the status Link 12 : Verify the Status of the data-module
13 : Verify the status of the ip-board
14 : Administer the DSA Application
6 : display communication-interface links
§ The link ( 1 ) should be shown as administered.
§ The link is administered in step 3, this step is only a verification.
§ Verify the data shown is correct.
NOTE :
Verify Node-Names, IP-Address, Gateway Address with Local LAN/WAN Administrator. Also check the * Microsoft® Support Knowledge Base Troubleshooting Wizards:
Article ID : Q163391; Q113342 ; Q102908 for additional assistance http://search.support.microsoft.com/kb http://search.support.microsoft.com/kb/c.asp?fr=0&SD=GN&LN=EN-US
* Microsoft®, Win32, MS-DOS, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
15 : Administer the BCMSVU Server Application
IP-SAT / BCMSVU on DEFINITY
ECS R9r, ECS R9si, ProLogix R9csi
Provided by:
jwysocki@avaya.com
05/01/2001 18:30 Hrs
Page 1 of 6
The following Tasks are required for activation
On DEFINITY ECS R9csi (ProLogix), ECS R9si, ECS R9r
change system-parameter maintenance page 2 of 3
1
SPE OPTIONAL BOARDS Packet Intf1? Y Packet Intf2? Y * Bus Bridge : 01A07
* Inter-Board Link Timeslots Pt0 : 6 Pt1 : 1 Pt2 : 1
NOTE: * Only On DEFINITY R9csi (ProLogix). Refer to Page 6 of 6
List configuration all or
2
List configuration Board <CLAN Bd Loc > Bd # BdType Code Vint Assigned Ports
u=unassigned t=tti p=p sa 1A07 CLAN TN799B 000001 u u u u u u u u
u u u u u u u u u
Add data-module 40000
3
Data Extension : 40000 Type : Ethernet Port : 01A0717 Link : 1 ( Node) Name : CLAN
Display Port 1A0717
4
PORT INFORMATION
Port : 1A0717 Equipment Type : Data Module Identification : 40000
List configuration all or
5
List configuration Board <1a07 >
IP-SAT / BCMSVu Server
display communication-interface links
6
INTERFACE LINKS Link Enable Est Ext Type Dest DTE Conn Name
Conn Number DCE Mod 1 Y N 40000 Ethernet CLAN 2 : 25
Confirm DSA Computer and BCMSVU Server IP Address:
7
§ Click on Start / Run / CMD
§ At the DOS Prompt type : ipconfig /all | more
§ Note the following items:
§ Computer Name
§ IP-Address
§ For DSA and BCMSVU the IP Address should be static ( NOT DHCP).
8
change node-names ip
Name IP Address default 0 . 0 . 0 . 0 NJ7460JWYSOCKI 135.8.32.?? NJ7460HUGHJOHN 135.8.32.?? bcmsvuserver 192.168.0 .2 CLAN 192.168.0.3
change ip-interfaces
9
IP INTERFACES Enable Net Eth Pt TYPE SLOT CODE Sfx Node Name Subnet Mask Gateway Address Rgn Y C-LAN 01A07 TN799 B CLAN 255.255.252.0 135.8.12.1 1
change ip-services
10
Service Enabled Local Local Remote Remote Type Node Port Node Port SAT y CLAN 5023 NJ7460JWYSOCKI 0
SAT y CLAN 5023 NJ7460HUGHJOHN 0 SAT y CLAN 5024 bcmsvuserver 0
Bd # BdType Code Vint Assigned Ports u=unassigned t=tti p=p sa
1A07 CLAN TN799B 000001 u u u u u u u u u u u u u u u u 17
IP-SAT / BCMSVU on DEFINITY
ECS R9r, ECS R9si, ProLogix R9csi
Provided by:
jwysocki@avaya.com
05/01/2001 18:30 Hrs
Page 2 of 6
Status Link 1 Page 1 of 4
11
Link / Port Status Link Number : 1 Link Status : Connected Link Type : Ethernet Link Name : CLAN Service Port Location : 01A0717 Service Port Data Extension : 40000 Service State : in-service/idle Node Name : CLAN Source IP Address : 192.168.0.3 Subnet Mask : 255 . 255. 252. 0 Broadcast Address : Physical Address : Enabled ? Yes Maintenance Busy ? no Active Channels : 0
status data-module 40000
12
DATA MODULE STATUS Data Ext/Stn Ext for Stn DM : Port / Channel Number : 01A0717 Service State : in-service / idle Maintenance Busy ? no CF Destination : Connected Ports :
status ip-board 1a07
13
IP STATUS Reset Time : Last Hour Start Time : End Time :
Page 2 of 4 Error Counters
Page 3 of 4 Processor Channel Status
Page 4 of 4 TCP / IP Applications Currently Active
Service Type Sessions Alarm1 0 Alarm2 0 CDR1 0 CDR2 0 DOLAN 0 PMS 0 PMS_JRNL 0 PMS_LOG 0 SAT 1 SAT_LSTN 0 SYS_PRNT 0
Incoming Received : Octets Datagrams Discards Hdr Errors Since Reset Last Hour Outgoing Transmitted: Since Reset Last Hour Datagrams w/o Routes : Since Reset Last Hour
IP-SAT / BCMSVU on DEFINITY
ECS R9r, ECS R9si, ProLogix R9csi
Provided by:
jwysocki@avaya.com
05/01/2001 18:30 Hrs
Page 3 of 6
DEFINITY Site Administration
System Properties - Switch
System Name : The Mick Default Emulator: 4410
Login: Login manually to system
1514a
BCMS VU R2 V2.0.0 Build 218
Server Window : Options / Configure / Switch Connection
Configuration Wizard Page 1 of 3 Login Name : bcmsvu Login Password : XXXXXXX
Type Dial/Host Port Serial Device Network xxx.xxx.xxx.xxx 5023
14b
DEFINITY Site Administration
Connection Properties
(Check) Network Connection Host : xxx.xxx.xxx.xxx Port : 5023
NOTE : CLAN IP Address : xxx.xxx.xxx.xxx
Configuration Wizard Page 2 of 3 Mode Connection : TCP/ IP Host Name / IP Address : xxx.xxx.xxx.xxx Port : 5024
Configuration Wizard Page 3 of 3 Test Connection
IP-SAT / BCMSVU on DEFINITY
ECS R9r, ECS R9si, ProLogix R9csi
Provided by:
jwysocki@avaya.com
05/01/2001 18:30 Hrs
Page 4 of 6
The following tasks need to be completed for Switch to BCMSVu Server.
1) Enable bus bridge connectivity
2) Assign Node Names
3) Assign IP Interface
4) Assign link (Add Data-Module Ext )
5) Assign IP Services
Customer LAN
SAT via DSA
BCMSVU Server
R2.0
Ethernet
C
789101112
Ethernet
123456
A
1x
ADJUNCTS
§ CDR1
§ CDR2PMS
§ PMS
§ PMS_JRNL
§ PMS_LOG
§ SYS_PRNT
§ ALARM1
§ ALARM2
§ ASAI01....ASAI12
Interface
Channels
1 5000 5001
Processor
Channels
1 2
5023 : SAT
5024 :
BCMSVu
12x6x8x2x9x3x10x4x11x5x7x
12x6x8x2x9x3x10x4x11x5x7x
1x
B
A
5101:CDR1
256 5102:CDR2 5103 : PMS
5104:
PMS_JRNL
5105 :
PMS_LOG
5106 :
SYS_PRNT
5107 :
Alarm1
5108 :
Alarm2
5678 :
ASAI01....
ASAI12
64500
IP-SAT / BCMSVU on DEFINITY
ECS R9r, ECS R9si, ProLogix R9csi
Provided by:
jwysocki@avaya.com
05/01/2001 18:30 Hrs
Page 5 of 6
C-LAN
TN799B/C
Bus Bridge
TDM Bus
DEFINITY PROLOGIX R9csi
Packet Bus
DEFINITY ECS R9csi ProLogix
DEFINITY ECS R9si
DEFINITY ECS R9r
10BT
C-LAN TN799
Processor
798B
TDM Bus
Bus Bridge
Packet Bus
10BT
C-LAN TN799
Processor
TN790B
Processor Bus
TDM BUS
PACKET BUS
NetPkt TN794
10BT
Network UN332B
C-LAN TN799
Processor Bus
Control
TDM BUS
Packet Bus
Processor
UN331B
PktInt
TN1655
DSA
Ethernet
BCMS
Vu
Hub
D8W
259A
Connector
back of
CLAN
1 A
TN799
0 7
IP-SAT / BCMSVU on DEFINITY
ECS R9r, ECS R9si, ProLogix R9csi
Provided by:
jwysocki@avaya.com
05/01/2001 18:30 Hrs
Page 6 of 6