Avanti ZeroWater Owner's Manual

USE AND CARE 1
OWNER’S MANUAL FILTER BOTTLE FOR STANDARD COOLERS
MEASURE AND TASTE THE DIFFERENCE!
000
2 USE AND CARE
MEASURE AND TASTE THE DIFFERENCE!
Bottled
1 2 4
Conventional Filtered
Tap
2 10
ZeroWater
000
076
12 4
21 0
Sample readings may vary. Test for yourself.
“000” =
FDA Standard for TDS
in Puried Water*
USE AND CARE 1
Congratulations on your purchase of a new ZeroWater® Filter Bottle!
Be prepared to taste the BEST tasting water like never before – we guarantee it! Your 5-Stage ZeroWater® lters are guaranteed to remove virtually all dissolved solids from your tap water. To nd out more about Zero Technologies, please visit www.zerowater.com.
Included in this brochure are simple instructions to help you assemble and maintain your ZeroWater
®
Filter Bottle. Now you’ll be able to start converting your own tap
water into ZeroWater®!
IMPORTANT!
Should you experience any diculties with water lters, before returning the product to the store, please call Customer Service toll free 24 hours a day, 7 days a week at 1-800-503-2939. Most issues can be resolved with a short phone call to our trained professionals.
SAFETY PRECAUTIONS
Do not use with water that is microbiologically unsafe or of unknown quality without proper disinfection before or after the system. Individuals requiring water of specic microbiological purity should consult their physician. Unless notied otherwise, municipal water is potable. The contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water.
PROPER INSTALLATION
Please read all instructions, specications, and precautions before installing and using your water ltration system.
* Filtered potable tap water tested by an independent lab (not the FDA) to meet specically the water quality requirements
for using the label “puried”. Compared to water produced by leading gravity fed lters.
Don’t forget to register your ZeroWater® Filter Bottle. Details are included on the enclosed Registration Card.
www.avantiproducts.com
2 USE AND CARE
IMPORTANT! Please read before rst use.
If you are using a water cooler with this product, please read this! Our ZeroWater® Filter Bottle ts most standard water coolers AFTER the splash guard is removed! If the splash guard is not removed, the oat valve on the ZeroWater® Filter Bottle will not work and will cause your water to spill!
DIRECTIONS FOR REMOVING THE SPLASH GUARD
If you look into the reservoir you’ll see the splash guard with a spike, used to pierce a hole in the cap of bulk water containers. Grip the splash guard, turn it counter clockwise and pull up on it. This should remove the splash guard from the water cooler. If you have further questions about this process with your particular model, you may need to refer to your user’s manual. If you still need assistance, please call our Customer Service number.
USE AND CARE 3
Patents: 5,635,063; 6,572,769; 7,276,161; 7,413,663; Additional patents pending.
RECYCLING
Filtering your water through ZeroWater® lters not only improves the taste of your tap water, it also prevents you from throwing plastic water bottles into the trash and clogging up landlls. Zero Technologies, LLC is proud to be the only major company that recycles gravity lter cartridges from U.S. customers.
If you wish to participate in this program, you will need to do a few simple steps to be sure the lters returned are processed accurately for recycling. Visit www.zerowater.com/recycling to download a form. Place your used lter into a sealable plastic bag and be sure it is sealed tightly. Place your used lters and your completed form in a well packed box and mail to the following address:
Zero Technologies, LLC 4510 Adams Circle Unit F Bensalem, PA 19020
Make sure to clearly mark your package “ATTN: RECYCLING PROGRAM”.
When the lter reaches us, the plastic as well as the materials inside it will be separated and sent to various facilities for reuse. We are asking customers to pay for shipping their exhausted lters to us. Additional information on this program, including discounts on future purchases, can be found at www.zerowater.com/ recycling.
If you have any questions about this program, please call the ZeroWater® customer service hotline 24 hours a day: 1-800-503-2939
4 USE AND CARE
LID
UPPER CHAMBER
FILTER CARTRIDGE
LOWER CHAMBER
FLOAT VALVE WITH SOFT WASHER
LOWER CHAMBER DIVIDER RIM
MAXIMUM WATER LEVEL
FILTER O-RING
USE AND CARE 5
ZeroWater® Filter Bottle Use and Care Instructions
Please read before rst use.
INSTRUCTIONS BEFORE INSTALLING CARTRIDGE AND FIRST USE
1. Clean all plastic components and lter cartridges by washing and rinsing thoroughly with warm water only. Rinse the Filter Bottle thoroughly when washing with soap.
2. Note: the Filter Bottle components, lter cartridges and TDS meter are not dishwasher safe.
3. Discard all plastic bags. This may be a suocation hazard to young children.
ASSEMBLY
1. Take the lower chamber and place the lower chamber divider rim rmly on the top. The rippled part of the white rim should be overlapping the lower chamber. If assembled upside down, there will be leakage. Be sure it ts tightly on the lower chamber (see ZeroWater® Filter Bottle components on page 4).
2. Screw oat valve tightly into hole on bottom of lower chamber (inset A). Do not prop the Filter Bottle on the oat valve once assembled, as it is fragile and will break.
3. Place the lower chamber on top of your cooler with the oat valve tting inside the cooler’s reservoir (see Using Your ZeroWater® Filter Bottle with a Standard Water Cooler on page 6).
4. Install lter cartridges now, using steps 1 and 2 from instructions on next page.
5. Place the upper chamber on top of the lower chamber. Be sure that the lower chamber divider ring is tightly axed around the lower chamber (see ZeroWater® Filter Bottle components on page 4).
A
6 USE AND CARE
INSTALLATION OF FILTER CARTRIDGES
1. Remove lter cartridges from packaging.
2. Tightly screw cartridge into hole on bottom side of reservoir to obtain a complete seal with the o-ring, otherwise your water will not read “000”(see ZeroWater® Filter Bottle components on page 4).
3. Place upper chamber with attached lter cartridges back onto the lower chamber divider rim of the lower chamber (see ZeroWater® Filter Bottle components on page 4).
If new lters are exposed to cold temperatures for prolonged periods, keep lters at room temperature for several hours before passing water through the rst time.
USING YOUR FILTER BOTTLE WITH A STANDARD WATER COOLER sold separately
1. Unplug your cooler.
2. Drain all water from the cooler using the spigots and the drain plug in the back of the cooler. Using a cooler without water in it, when plugged in, can cause it to smoke and break. Make sure you secure the drain plug when you are nished draining the cooler.
3. Be sure you have removed the splashguard from the cooler reservoir. Refer to page (2) for directions.
4. Clean the reservoir and spigots by mixing 1 tablespoon of baking soda into 1 gallon of hot water and pouring the solution directly into the cooler reservoir.
5. Let solution sit for about 30 minutes and then drain through spigots and drain plug.
6. Flush the cooler with three gallons of plain hot water using same method. Secure the drain plug. The total capacity of the bottom chamber is three gallons.
7. Do not replace the splashguard or spike xture.
8. Now your cooler is ready for your assembled ZeroWater® Filter Bottle. Add water before plugging cooler back into electrical outlet (See step 6 under section “Filling the ZeroWater® Filter Bottle with Tap Water on page 7).”
USE AND CARE 7
FILLING THE FILTER BOTTLE WITH TAP WATER
1. Remove lid.
2. Slowly ll the upper reservoir with cold tap water. Be careful not to dump water too quickly into the upper chamber when the lower chamber is empty because it may tip and spill.
3. Allow water to pass from the upper chamber through the lters to the lower chamber. Water will be ready to drink in several minutes.
4. Test the water using the TDS meter to conrm a “000” reading.
5. If it doesn’t read “000”, ush the water out and pour new water through.
6. Do not over ll. The rst time you ll your Filter Bottle it will take extra water to ll the cooler reservoir. When water in the lower chamber reaches the divider rim do not put any more water in the upper chamber, as it may leak. The upper chamber is not designed to be a long term reservoir.
Safety Precautions: Do not use with water that is microbiologically unsafe or of
unknown quality without proper disinfection before or after the system. Individuals requiring water of specic microbiological purity should consult their physician. Unless notied otherwise, municipal water is potable.
Loading...
+ 19 hidden pages