INTRODUCTION
The Avanti Z60 thermal remote control system was developed with the latest radio frequency (RF) technology. The Avanti Z60 is easy to install. It allows the user to operate a gas appliance manually or thermostatically with a user-friendly remote control system which does not require any household electric current. The range of operation is approximately 20 feet (7 meters). The operating code of this remote control system has been pre-programmed for instant operation after installation. However, its special code-learning feature (on the receiver) allows the user to regulate the codes for operating with other transmitters for a maximum flexibility. Note: installation in metal cabinets may limit the range of operation
COMPONENTS INCLUDED
TRANSMITTER
WALL-MOUNT COVERPLATE
SLIDE BUTTONS
WALL MOUNT BRACKET
Description QTY Transmitter 1 “AAA” Batteries 2 Wall Mount Bracket (with Screws) 1 Receiver 1 “AA” Batteries 4 Wall Mount faceplate (with Screws) 1 7) Velcro at the bottom of the box Hearth Mount Slide knob (Black) 1
Wall Mount Slide knob (White) 1 Velcro 1
INSTALLING Z60 REMOTE SYSTEM
(A) Getting the Transmitter Ready:
1.
Installing Batteries
The transmitter operates on 2 AAA-size 1.5V batteries. It is recommended that ALKALINE
batteries always be used for longer battery life and maximum operational performance. Rechargeable batteries are not recommended.
(1) Open the lid of the battery compartment on the back of the transmitter. (2) Insert 2 new or fully charged AAA-size 1.5V batteries into the battery compartment. Make
sure the (+) and (-) ends of the batteries are correctly positioned as indicated on the casing.
(3) When the batteries are installed, the LCD with similar numbers will display.
+
_
AAA
+
_
AAA
Insert Batteri e s
Note 1:
On initial start up if a low battery indicator appears on the screen, you should either check the positions of the batteries or replace with new batteries. Note 2: It may take a few minutes (up to 15 minutes on a severe cold weather) for accurate room temperature readings to appear after the batteries have been installed.
2.
LCD Display
RF signal – Appears when signals are being emitted
Thermostat Indicator – Thermo Off appears when it’s manually on; Thermo On appears
when thermostat is activated.
Manual On/ Temp Set ON shows when its manually turned on; set temperature shows
when thermostat is in operation
Clock – Indicates the current time in AM/PM ⑤ Room – Indicates current room temperature ⑥ Flame – Indicates burner/ valve in operation ⑦ Battery – Battery power is low. Replace batteries within 2 weeks ⑧ Timer – Indicates time remaining before system shuts off when timer-programmed; 9-hour
maximum setting
Lock Childproof lock-out
3.
Control Buttons
ON/OFF UP TIMER/
CLOCK
THERMOSTAT DOWN
SET
3.
Setting the Clock
(1) Press and hold the “Timer/Clock” button for more than five seconds, the
hour digit(s) will begin flashing.
(2) Press the ▲ (UP) or ▼ (DOWN) button until the desired hour is
displayed in AM or PM.
(3) After setting the desired hour, push the “Timer/Clock” button again to set
the minutes. The minute digits will begin flashing.
(4) Press the ▲ (UP) or ▼ (DOWN) button until the desired minute is displayed. (5) Press the SET button, the minute digits will stop flashing, indicating the clock has been
successfully set.
Note:
Flashing digits on LCD indicate the system is awaiting user’s input as mentioned above.
The digits will stop flashing if no input is made within 10 seconds and the setting is automatically completed.
4.
Setting
/
Scale
The factory setting for temperature is(Fahrenheit). To change this setting to (Celsius): (1) Remove the battery cover on the back of the transmitter.
F
AM
ROOM
oFo
C
+
_
A
AA
+
_
AAA
oF/o
C Switch
(2) Adjust the temperature scale Dip Switch (on the left hand side, with/mark) with your
fingernail or a ball pen point and move it to the scale on the right.
To change from ℃ back to ℉, move the dip switch back to ℉ again.
5.
Operation Functions
Note: The slide switch on the receiver must be placed in the REMOTE position for receivin g
commands from the transmitter. In other words, the transmitter (remote control) only works when the receiver is set in the REMOTE mode (Also refer to instructions in the RECEIVER section in this manual). To change the settings on the receiver, install the black knob on the receiver by pushing the knob gently on the control.
(1) Turning ON/OFF the Fireplace:
1 To turn the fireplace on, press the ψ (ON/OFF) button on the
transmitter. The text ON and the flame icon will appear on the LCD. A thermo bulb and texts THERMO OFF are also seen on the LCD indicating the system is manually on but not thermostatically operating.
2 Press the ψ(ON/OFF) button again to turn off the fireplace. The text
ON, flame icon and thermo bulb will disappear from the LCD.
(2) Setting Desired Temperature (THERMOSTAT):
This remote control system can be thermostatically controlled by activating the THERMOSTAT (Auto) function from the transmitter:
1 Press the ψ(ON/OFF) button to turn on the fireplace. The text ON, the flame icon, the
thermo bulb and texts THERMO OFF will appear on the LCD.
2 Press the AUTO button, the thermo bulb icon and texts THERMO ON will appear on the
top row of LCD, the text ON will become THERMO TEMPERATURE.
3 Press the ▲ (UP) or ▼ (DOWN) button to select the desired thermo temperature. The
system will operate thermostatically as per your selected thermo temperature.
THERMO
ON
F
F
AM
THERMO SET
ROOM
Ã
Thermo ON/Fireplace ON
THERMO
ON
F
F
AM
THERMO SET
ROOM
Ã
Thermo ON/Fireplace OF
F
To disengage the THERMO function, press the AUTO button again, it will return to the
manual ON mode. To completely turn off the fireplace, press the ψ(ON/OFF ) button.
F
AM
ROOM
THERMO
OFF
Ã
6.
Setting the Countdown Timer
The Avanti Z60 can be programmed to operate with a built-in countdown timer when the
transmitter is in the ON or THERMO modes.
To operate the timer,
(1) Press the “Timer/Clock” button on the transmitter, “TIMER” icon will
show and the minimum time of 0:15 minutes on LCD will begin flashing.
(2) Press the ▲ (UP) or ▼ (DOWN) button to begin advancing through
each of the countdown time options. Available countdown times are 15 minutes, 30 minutes 45 minutes, 1 hour, 1 hour 30 minutes, 2 hours, 2 hours and 30minutes, and each additional half-hour increments up to nine hours.
(3) Press the SET button when countdown time is selected. (The timer will set automatically
even if you don’t press the SET button in 10 seconds before the “time” stops flashing.) The fireplace will remain on until the set time has expired.
(4) To cancel the countdown timer, press the “Timer/Clock” button again, TIMER and remaining
countdown time will disappear from LCD.
7.
Childproof “Lock-Out”
Avanti Z60 includes a CHILDPROOF “LOCK-OUT” safety feature that allows the user to “LOCK-OUT” operation of the appliance from the TRANSMITTER.
To activate the Lock-Out feature,
(1) Remove the battery cover on the back of the transmitter. (2) Slide the lock-out Dip Switch with your fingernail or a ball pen point to the right (with a
locked lock icon) to activate the childproof feature. The lock icon will appear on the LCD screen.
F C
+
_
AAA
+
_
AAA
Lock Swi tc
h
To disengage the childproof lock-out,
Slide the lock-out Dip Switch to the left (with an unlocked lock icon). The lock icon will disappear from the LCD screen and the transmitter will return to its normal operating condition.
NOTE:
If the appliance is already operating in the ON or THERMO modes, engaging the
F
AM
ROOM
THERMO
OFF
Ã
TIMER
Count down timer ON
THERMO
ON
F
AM
ROOM