Autonics LA8N-BN, LA8N-BV, LA8N-BN-L, LA8N-BF, LA8N-BV-L Instruction Manual

...
DRW171142AA
COUNTER/TIMER
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.

Safety Considerations

Please observe all safety considerations for safe and proper product operation to avoid hazards.
Safety considerations are categorized as follows.
Warning Failure to follow these instructions may result in serious injury or death. Caution
Failure to follow these instructions may result in personal injury or product damage.
The symbols used on the product and instruction manual represent the following
symbol represents caution due to special circumstances in which hazards may occur.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Install on a device panel to use.
Failure to follow this instruction may result in re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
4. Check ‘Connections’ before wiring.
Failure to follow this instruction may result in re.
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
6. Since Lithium battery is embedded in the product, do not disassemble or burn the unit.
Failure to follow this instruction may result in re.
Caution
1.
When connecting the power/sensor input and relay output, use AWG 20
tighten the terminal screw with a tightening torque of 0.74 to 0.90N.m.
Failure to follow this instruction may result in re or malfunction due to contact failure.
2. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
3. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in re.
4. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
5. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.

Ordering Information

L
A 8 N B N L
Backlight
Input type
Power supply
Size
Digit
Item
Display
Upgraded or added functions are seen in the shaded part of ordering information.

Dimensions

●Bracket ●Panel cut-out
The above specications are subject to change and some models may be discontinued without notice.
Be sure to follow cautions written in the instruction manual and the technical descriptions
(catalog, homepage).
RESET
48
24
LA8N
36
4 54
Min. 37
(0.50mm2) cable or over, and
No mark None
L Backlight function
N No-voltage input
V Voltage input
F Free voltage input
B Built-in battery
N DIN W48×H24mm
8 99999999(8digit)
A Counter
E Timer
L LCD Display
1
Min. 55
+0.6
45
0
(unit: mm)
22.2
Specications
Model
Digit 8digit (Count up, Count down, Count up/down: -9999999 to 99999999 / Count up: 0 to 99999999) 8digit (0 to 99999999) Digit size W3.4 × H8.7mm Display method LCD Zero Blanking type (Character height size: 8.7mm)
Operation method
Power supply Built-in battery Battery life cycle Approx. over 7 years at 20 Backlight power supply Input method No-voltage input Voltage input Free voltage input No-voltage input Voltage input Free voltage input
Count input (Counter)
Start input (Timer)
RESET input No-voltage input Voltage input No-voltage input No-voltage input Voltage input No-voltage input
Min. signal width
Max. counting speed 1cps / 30cps / 1kcps 20cps
Time specication (TS1) Time specication (TS2) Time specication (TS3)
Time error External set switch SW1 Insulation resistance Min. 100MΩ (at 500VDC megger) Dielectric strength
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 1 hour
Vibra­tion
Malfunction 0.3mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 10 minutes Mechanical 300m/s2 (Approx. 30G) in each X, Y, Z direction for 3 times
Shock
Malfunction 100m/s2 (Approx. 10G) in each X, Y, Z direction for 3 times Ambient temp. -10 to 55℃, Storage: -25 to 65
Enviro­nment
Ambient humi. 35 to 85%RH, Storage: 35 to 85%RH Protection IP66 (when using waterproof rubber for front panel) Accessory Mounting bracket, Rubber waterproof ring Approval
7
Weight
1: SW1 is the front panel RESET key enable/disable set switch. ※2: SW2 is the max. counting speed set switch. ※3: SW3 is the decimal point set switch.
4: SW2 is the time range set switch. ※5: SW3 is available to select time specification TS1, TS2, or TS3.
6: No-voltage input, voltage input: between all terminals and the case / Free voltage input: between the free voltage input terminal and the RESET input terminal, between all terminals and the case
Environment resistance is rated at no freezing or condensation. ※7: The weight includes packaging. The weight in parentheses is for unit only.

Connections

Input type
Backlight Counter Timer
-
No­voltage input type
Backlight function
-
Voltage input type
Backlight function
22
+0.3
Free voltage
0
input type
1: Terminal 2 and 5 are connected inside. (Non-isolated)
Use reliable contacts enough to flow 3VDC 5㎂ current.
LA8N Series (Counter) LE8N Series (Timer) LA8N-BN LA8N-BN-L LA8N-BV LA8N-BV-L LA8N-BF LE8N-BN LE8N-BN-L LE8N-BV LE8N-BV-L LE8N-BF
Count up, Count down, Count up/down
-
Residual voltage: Max. 0.5VDC
Short-circuit impedance: Max. 10kΩ Open-circuit impedance: Min. 750kΩ
UP/DOWN, RESET input: Min. 20ms
-
-
-
-
1
, SW2
6
2,000VAC 60Hz for 1minute
2
, SW3
Count up
24VDCЗ ±10%
RESET input: Min. 20ms
3
Count up, Count down, Count up/down
-
"H" level voltage: 4.5-30VDC "L" level voltage: 0-2VDC
UP/DOWN, RESET input: Min. 20ms
Count up Count up Count up
24VDCЗ ±10%
З
RESET input: Min. 20ms
- -
"H" level voltage: 24-240VAC /6-240VDC "L" level voltage: 0-2VAC/0-2.4VDC
RESET input: Min. 20ms
1
SW1
, SW3
Approx. 10 years at 20
Residual voltage: Max. 0.5VDC
ᜠ ᜡ
Short-circuit impedance: Max. 10kΩ Open-circuit impedance: Min. 750kΩ
SIGNAL INPUT, RESET input: Min.20ms
-
999(5(59 999(2#59 9999;5(9
±0.01% (Time error, Temperature error)
3
SW1
1
, SW2
(h.m.s), (d.h.m), (h.m),
4
, SW3
24VDCЗ ±10%
9999(5(9 9999D2#9
99999;59
5
-
"H" level voltage: 4.5-30VDC "L" level voltage: 0-2VDC
(h.m),
99999(59
(d.h),
99999999
(h.m),
99999(9;
(h)
(h.m)
(s)
24VDCЗ ±10%
З
ᜢ ᜧ
Approx. 96g (Approx. 50g)

Set Switch

SW1( 1 Switch )
●LA8N-BN
1
SIGNAL
INPUT
1
2
●LE8N-BN
3 4 5
RESETUP/DOWN
1
SIGNAL
INPUT
1
2
●LA8N-BN-L/LE8N-BN-L
1
2
3 4 5
+ -
SIGNAL
RESET
RESET
UP/DOWN
3 4 5
SIGNAL
INPUT
+
-
1
INPUT
2
Terminal (1, 2, 3) and (4, 5) are insulated inside.
1
●LA8N-BV
SIGNAL
INPUT
1
2
+ -
4.5-30VDC
●LA8N-BV-L/LE8N-BV-L
4.5-30VDC
Terminal (1, 2, 3) and (4, 5) are insulated inside.
Signal input (SIGNAL INPUT, RESET) is available by backlight power.
24VDC
BACKLIGHT
●LE8N-BV
SIGNAL
INPUT
1
+ -
4.5-30VDC
RESET
3 4 5
1
2
+
-
●LA8N-BF/LE8N-BF
1
2
3 4 5
!
~
24-240VAC 50/60Hz
+ -
!
6-240VDC
Terminal (1, 2) and (4, 5) are insulated inside.
SIGNAL INPUT
RESET
3 4 5
RESET
RESET
3 4 5
24VDC
BACKLIGHT
●LA8N / LE8N Series SW1 is a switch to Enable/
Disable the front panel RESET key.
Factory default: Enable
SW2( 2 Switch )
●LA8N Series SW2 is a switch for setting max. counting speed.
Factory default: 1cps
(
Free voltage input type:
20cps is fixed)
LE8N Series
SW2 is a switch for setting time range.
Factory default:
SW3
LE8N Series
SW3 is a switch for setting time sepcification. TS1, TS2, TS3 (
999(5(59
(h.m.s)
1
2
2
Front panel
Enable Disable
Refer to "<Time range>" table of
SW3 for ①, ②, ③ descriptions.
Factory default: TS1)
<Set TS1> <Set TS2> <Set TS3>
TS1 TS2 TS3
<Time range>
TS1 TS2 TS3
1
TS1 TS2 TS3
TS1 TS2 TS3
TS1 TS2 TS3
1: Time range is set as SW2, SW3 combination.
●LA8N Series SW3 is a switch for decimal point position.(※Factory default: No decimal point)
+
LITHUM BA
3V
hour min.
99999(59
hour min.
9999(5(9
hour min. sec.
999(5(59
99999999
day hour
9999D2#9
day hour min.
999(2#59
SW3 Decimal point
2
Not use decimal point
1
ON
2
1
ON
2
1
ON
Change SW3 setting after removing the case.
※ ※
Supply RESET signal (front panel or terminal RESET), after setting SW2, SW3 during operation.
How to change settings
Power OFF → change settings → power ON → press RESET key or input signal (min. 20ms)
+
LITHUM BA
3V
2
1
ON
2
1
ON
-
"H" level voltage: 24-240VAC /6-240VDC "L" level voltage: 0-2VAC/0-2.4VDC
2
30cps1kcps
2
sec.
99999(9;
99999;59
9999;5(9
)0
)00
)000
1
Front panel
1cps
Front panel
Battery holder
direction
hour
hour min.
hour min.

Operation

Counter operation(LA8N-BN/LA8N-BV model)
H
SIGNAL
INPUT
L
UP/
H
DOWN
L
2
1
Counting
0
value
should be over 20ms of min. signal width. If it is below 20ms, it may cause counting error.
Counter operation
(LA8N-BN-L/LA8N-BV-L/LA8N-BF model)
H
RESET
L
SIGNAL
H
L
INPUT
Counting
value
0
1
0
-1
-2
99999999
99999998
4
3
2
1
SIGNAL INPUT: Counting input,
UP/DOWN: Counting instruction input
UP/DOWN as "L" is count up (UP)
UP/DOWN as "H" is count down (DOWN)
The meaning of "H" and "L"
Voltage input No-voltage input Free voltage input
1
H 4.5-30VDC Short 24-240VAC/6-240VDC
0
-1
L 0-2VDC Open 0-2VAC/0-2.4VDC
Timer operation (LE8N Series)
RESET
SIGNAL
INPUT
Max. time
range
1
0
H L
H
L
0

Case Detachment

Hold up Lock part toward product with the tool and pull toward ③ to detach the case.
When using the tools, be careful
!
not to be wounded.
①, ②
of the

Battery Replacement

1.Detach the case.
2.Push the battery and detach it toward ①.
3.Insert a new battery with correct alignment of polarity pushing it toward opposite of ①.
Since lithium battery is embedded in the product, follow instructions below for safety.
Do not charge, short, disassemble, subject it to shock, heat.
Check the polarity.
Use CR2477 battery.
Do not solder on a battery directly.
Insulate a battery with tape to dispose .
Do not store this unit in the place with the direct sunlight,
high temperature and humidity.
※The
battery is sold separately. Please replace a battery by yourself.
Do not burn up or disassemble the lithium battery.
+
LITHUM BATTERY
3V

Connection for AC Type

(Fig. 1) (Fig. 2)
AC type
proximity
sensor
In case of free voltage input type, connect a relay as figure 2. In case connecting AC proximity sensors instead of a relay as figure 1, it may cause malfunction due to leakage current of the sensor.
SIGNAL INPUT RESET
2 3
1
~
100-240VAC
<Example of wrong connection> <Example of correct connection>
4 5
!
SIGNAL INPUT RESET
2
3
Relay
4 5
!
1
100-240VAC
~
AC type
proximity
sensor

Caution during Use

1. Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
2. In case of contact input, set count speed to low speed mode (1cps, 20cps, 30cps) to operate. If set to high speed mode (1kcps), counting error occurs due to chattering.
3. Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line lter or varistor at power line and
shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.
4. This product may be used in the following environments.
Indoors (in the environment condition rated in ‘Specications’)
Altitude max. 2,000m
Pollution degree 2
Installation category II

Major Products

Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometers/Pulse(Rate)Meters Rotary Encoders Display Units Connectors/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System(Fiber, CO₂, Nd:YAG) Laser Welding/Cutting System
http://www.autonics.com
HEAD QUARTERS:
18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan, South Korea, 48002 TEL: 82-51-519-3232
E-mail: sales@autonics.com
DRW171142AA