● Easy software upgrade available on website
(1) GP rmware le
(2) GP Editor (drawing program)
(3) Additional protocol
● Dierent devices monitoring function
: Allows to monitor and control the variables of additionally
connected controllers (such as PLC) with external
communication port
● Supports multilingual
: Supports Korean, Japanese, English, Chinese, Russian,
Vietnamese and Portuguese.
Additional languages will be available by rmware.
● Supports multi-font
: It provides various bitmap and user-selected fonts.
● Various multi-communication port
: Both RS232C 2 port or RS232C/RS422 compound port are provided.
● Device monitoring function
: It enables to monitor GP devices and connected controller devices by GP without graphic design data.
●Printer and barcode reader connection
: It enables to print alarm history connecting a printer and read barcode connecting a barcode reader.
● Compact design
: Minimizes module size and installation places by 5.7 inch display
● Various display function
: It displays data by various tags.
area
Please read “Safety Considerations”
in the instruction manual before using.
Manual
For the detail information and instructions, please refer to user manual and user manual for communication, and be sure to
follow cautions written in the technical descriptions (catalog, website).
Visit our website (www.autonics.com) to download manuals.
● GP Editor user manual
It describes how to write screen data, and is about related usage of GP-S057 HMI function.
● GP/LP user manual for communication
It describes connection for external devices such as PLC.
● GP-S044/S057 user manual
It describes general information on the installation and usage of GP-S057 and system contents.
Model
Power supply24VDCᜡ
Allowable voltage range90 to 110% of power supply
Power consumptionMax. 3.6W
LCD type5.7 inch STN blue negative
Resolution320×240 dots
Display area119×91mm
ColorMONO (blue, white)
LCD view angleTop/Bottom/Left/Right within 30°in each direction
BacklightWhite LED
BrightnessAdjustable by software
Display performance
Language
※
1
Text
Graphic drawing memory 512 KB
performance
Number of user screen500 pages
Graphic drawing
Touch switchWidth 16×Height 12 = 192
Serial interface
Real-time controllerRTC embedded
Battery life cycleApprox. 3 years at 25℃
Insulation resistanceOver 100MΩ (at 500VDC megger)
Ground3rd grounding (max. 100Ω)
Noise immunity± 0.5kV the square wave noise (pulse width: 1㎲) by the noise simulator
Dielectric strength500VAC (50/60Hz) for 1 min
Vibration
Shock
Environ
-ment
Mechanical0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temperature 0 to 50℃, storage: -20 to 60℃
Numeral displayDisplays the designated device as numerical value. (decimal, hexadecimal, octal, binary, real number)
ASCII displayDisplays the designated device value as ASCII character.
Time displayDisplays current time or date.
Alarm historyRegisters alarm history.
Alarm listDisplays generated (not backed up) alarm.
Comment displayDisplays the designated comment as device status or value.
LampDisplays lamp as device status.
Part displayDisplays the designated parts as device status and value.
Tags
Line graphDisplays several device values with a graph of broken line.
Trend graphDisplays change of device value for time with a graph of broken line.
Bar graphDisplays a device value with a bar graph.
Statistic graphDisplays a ratio of several device values with pie graph.
Panel meterDisplays a device value as panel meter.
Touch keyScreen is switched, word/bit device values are set when it touched.
Numeral inputCongures user input value in device.
ASCII inputCongures user input ASCII code value in device.
System information functionMonitors/Controls GP operation from PLC.
Recipe functionReads/Writes several PLC device collectively.
Security functionOnly acceptable user can observe/operate important data.
Barcode read functionConnects barcode reader, read barcode.
Floating alarm functionWarning message is oated when alarm is generated.
Time operationSpecic bit device is ON/OFF for designated day and time.
Overlap windowAvailable to form dynamically overlapping another base screen on the base one.
Observe status functionChanges PLC device status/value of PLC when trigger is generated.
• High resolution display up to 1590 letters (6×8 font) • 6×8, 8×8 ASCII character, high denition numbers
• 8×16 ASCII characters, 16×16 character by each country
(1-8 times bigger for width, 0.5-5 times bigger for height)
Each port of RS232C, RS422 (asynchronous method)
Two ports of RS232C (asynchronous method)
Approx. 565g (approx. 386g)
V-43
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
GP-S057 Series
Dimensions
143
156
Unit Description
Fixing bracket
132
● Panel cut-out
(unit: mm)
Min. 178
+ 0.5
- 0
116
30.5
5
Min. 150
R5
+ 0.5
144
- 0
※
Panel thickness
: max. 4mm
● Fixing bracket
115
134
Fixing bracket
17.5
M3 BOLT
15.6
8
V-44
LCD screen
Power
terminal block
※
Communication port
1:
Model
GP-S057-S1D0 RS422 RS232C
GP-S057-S1D1 RS232C-A RS232C-B
※
For more information, refer to ' Serial
Communication
port A
Communication
port
Port APort B
※
1
Communication
port B
※
Interface' of GP/LP Common Features.
1
Basic Type 5.7 inch Mono Graphic Panel
Installation
1. Set a waterproof rubber ring after placing the joining part of the ring under the GP-S057.
2. Adhere closely between each edge of the GP-S057 and the rings.
3. Set GP-S057 in panel.
4. Set the fixing bracket to 4 bracket slots and fix them with the screw of the bracket.
SENSORS
CONTROLLERS
Upper side
Mounting slot
for bracket
Waterproof
rubber ring
Lower side
● Fixing bracket
M3 screw driver approx. 0.3N·m
Serial Interface
● All devices are connectable with GP-S057 including PC, PLC, serial printer, barcode reader and dedicated connectors
can be connected with both RS232C and RS422 ports.
● Use the dedicated communication cable for the each connected device.
(Refer to the "GP/LP Communication Cables")
● For the method of wiring external devices like PLC, refer to "GP/LP communication manual".
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
PortNO. Pin
RS232C
5
4
3
2
1
D-Sub 9-pin
Male
RS422
5
4
3
2
1
D-Sub 9-pin
Female
9
8
7
6
6
7
8
9
1Not used
2RXD
3TXD
4DTR
5SG
6DSR
7Not used
8Not used
9Not used
1TXD+
2RXD+
3Not used
4Not used
5SG
6TXD7RXD8Not used
9Not used
V-45
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
GP-S057 Series
Cable (sold separately)
Serial connection cables which connect GP/LP with PLC or other external devices are sold separately.
Refer to "GP/LP Communication Cables".
Power Wiring
● For power supply, use the wire of which cross section is at least 0.75mm² and
use the wire of which cross section is at least 1.25mm² for grounding.
● Use round terminal with at least 3mm of internal diameter and less than 6mm of
external diameter.
● Do not apply power before power line connection.
● Check power polarity.
● Tighten the terminal screw with 0.5 to 0.8N·m torque.
● Ground resistance should be less than 100Ω and ground it separately.
Battery Replacement
Please contact out distributor to replace battery.
It may cause an explosion or a fire when improper battery is used.
+
+
24VDC
F.G.
-
-
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
4. Operate the product after supplying power to the product, input/output equipment, and load.
If operate product before supplying power, it may result in output error or malfunction.
5. Keep away from high voltage lines or power lines to prevent inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Make a required space around the unit for radiation of heat, and do not block ventilation openings.
7. Do not push the touch panel with a hard and sharp object or push the panel with excessive force.
It may result in fire or malfunction.
8. When skin is smeared with liquid crystal from the broken LCD, rinse with running water for over 15 minutes.
If it gets into the eyes, rinse eyes with running water for over 15 minutes and contact a doctor.
9. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category II
④
V-46
Loading...