Autonics GP-S057 Series Catalog Page

GP-S057 Series
Basic Type 5.7 inch Mono LCD Graphic Panel
Features
● Displays max. 1590 characters
● Enables to save max. 500 pages of user screen
● Easy software upgrade available on website (1) GP rmware le (2) GP Editor (drawing program) (3) Additional protocol
: Allows to monitor and control the variables of additionally
connected controllers (such as PLC) with external communication port
● Supports multilingual
: Supports Korean, Japanese, English, Chinese, Russian, Vietnamese and Portuguese.
Additional languages will be available by rmware.
● Supports multi-font
: It provides various bitmap and user-selected fonts.
● Various multi-communication port
: Both RS232C 2 port or RS232C/RS422 compound port are provided.
● Device monitoring function
: It enables to monitor GP devices and connected controller devices by GP without graphic design data.
●Printer and barcode reader connection
: It enables to print alarm history connecting a printer and read barcode connecting a barcode reader.
● Compact design
: Minimizes module size and installation places by 5.7 inch display
● Various display function
: It displays data by various tags.
area
Please read “Safety Considerations” in the instruction manual before using.
Manual
For the detail information and instructions, please refer to user manual and user manual for communication, and be sure to follow cautions written in the technical descriptions (catalog, website). Visit our website (www.autonics.com) to download manuals.
● GP Editor user manual
It describes how to write screen data, and is about related usage of GP-S057 HMI function.
● GP/LP user manual for communication
It describes connection for external devices such as PLC.
● GP-S044/S057 user manual
It describes general information on the installation and usage of GP-S057 and system contents.
Ordering Information
Model Item Series Monitor size Display unit Color Power supply Interface
GP-S057-S1D0
GP-S057-S1D1
Graphic panel S series 5.7 inch STN LCD
MONO (blue, white)
24VDC
Each port of RS232C, RS422
Two ports of RS232C
V-42
Basic Type 5.7 inch Mono Graphic Panel
Specifications
Model Power supply 24VDC Allowable voltage range 90 to 110% of power supply Power consumption Max. 3.6W
LCD type 5.7 inch STN blue negative Resolution 320×240 dots Display area 119×91mm Color MONO (blue, white) LCD view angle Top/Bottom/Left/Right within 30°in each direction Backlight White LED Brightness Adjustable by software
Display performance
Language
1
Text
Graphic drawing memory 512 KB
performance
Number of user screen 500 pages
Graphic drawing
Touch switch Width 16×Height 12 = 192 Serial interface Real-time controller RTC embedded Battery life cycle Approx. 3 years at 25 Insulation resistance Over 100MΩ (at 500VDC megger) Ground 3rd grounding (max. 100Ω) Noise immunity ± 0.5kV the square wave noise (pulse width: 1) by the noise simulator Dielectric strength 500VAC (50/60Hz) for 1 min
Vibration
Shock
Environ
-ment
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction for 3 times Ambient temperature 0 to 50, storage: -20 to 60
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH Protection structure IP65 (front panel, IEC standard) Accessory Fixing bracket: 4, waterproof rubber ring, battery (included)
Approval
2
Weight
1: Supported language can be added. ※2: The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.
Function
Figure display Line, rectangle, circle, text, bitmap
Numeral display Displays the designated device as numerical value. (decimal, hexadecimal, octal, binary, real number) ASCII display Displays the designated device value as ASCII character. Time display Displays current time or date. Alarm history Registers alarm history. Alarm list Displays generated (not backed up) alarm. Comment display Displays the designated comment as device status or value. Lamp Displays lamp as device status. Part display Displays the designated parts as device status and value.
Tags
Line graph Displays several device values with a graph of broken line. Trend graph Displays change of device value for time with a graph of broken line. Bar graph Displays a device value with a bar graph. Statistic graph Displays a ratio of several device values with pie graph. Panel meter Displays a device value as panel meter. Touch key Screen is switched, word/bit device values are set when it touched. Numeral input Congures user input value in device.
ASCII input Congures user input ASCII code value in device. System information function Monitors/Controls GP operation from PLC. Recipe function Reads/Writes several PLC device collectively. Security function Only acceptable user can observe/operate important data. Barcode read function Connects barcode reader, read barcode. Floating alarm function Warning message is oated when alarm is generated. Time operation Specic bit device is ON/OFF for designated day and time. Overlap window Available to form dynamically overlapping another base screen on the base one. Observe status function Changes PLC device status/value of PLC when trigger is generated.
GP-S057-S1D0 GP-S057-S1D1
English, Korean, Japanese, Chinese, Russian, Vietnamese, Portuguese
• High resolution display up to 1590 letters (6×8 font) • 6×8, 8×8 ASCII character, high denition numbers
• 8×16 ASCII characters, 16×16 character by each country (1-8 times bigger for width, 0.5-5 times bigger for height)
Each port of RS232C, RS422 (asynchronous method)
Two ports of RS232C (asynchronous method)
Approx. 565g (approx. 386g)
V-43
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
GP-S057 Series
Dimensions
143
156
Unit Description
Fixing bracket
132
● Panel cut-out
(unit: mm)
Min. 178
+ 0.5
- 0
116
30.5
5
Min. 150
R5
+ 0.5
144
- 0
Panel thickness : max. 4mm
● Fixing bracket
115
134
Fixing bracket
17.5 M3 BOLT
15.6
8
V-44
LCD screen
Power
terminal block
Communication port
1:
Model
GP-S057-S1D0 RS422 RS232C
GP-S057-S1D1 RS232C-A RS232C-B
For more information, refer to ' Serial
Communication
port A
Communication
port
Port A Port B
1
Communication
port B
Interface' of GP/LP Common Features.
1
Basic Type 5.7 inch Mono Graphic Panel
Installation
1. Set a waterproof rubber ring after placing the joining part of the ring under the GP-S057.
2. Adhere closely between each edge of the GP-S057 and the rings.
3. Set GP-S057 in panel.
4. Set the fixing bracket to 4 bracket slots and fix them with the screw of the bracket.
SENSORS
CONTROLLERS
Upper side
Mounting slot
for bracket
Waterproof rubber ring
Lower side
● Fixing bracket
M3 screw driver approx. 0.3N·m
Serial Interface
● All devices are connectable with GP-S057 including PC, PLC, serial printer, barcode reader and dedicated connectors can be connected with both RS232C and RS422 ports.
● Use the dedicated communication cable for the each connected device.
(Refer to the "GP/LP Communication Cables")
● For the method of wiring external devices like PLC, refer to "GP/LP communication manual".
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
Port NO. Pin RS232C
5
4
3
2
1
D-Sub 9-pin
Male
RS422
5
4
3
2
1
D-Sub 9-pin
Female
9
8
7
6
6
7
8
9
1 Not used
2 RXD 3 TXD 4 DTR
5 SG 6 DSR 7 Not used 8 Not used 9 Not used 1 TXD+
2 RXD+ 3 Not used 4 Not used
5 SG 6 TXD­7 RXD­8 Not used 9 Not used
V-45
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
GP-S057 Series
Cable (sold separately)
Serial connection cables which connect GP/LP with PLC or other external devices are sold separately. Refer to "GP/LP Communication Cables".
Power Wiring
● For power supply, use the wire of which cross section is at least 0.75mm² and use the wire of which cross section is at least 1.25mm² for grounding.
● Use round terminal with at least 3mm of internal diameter and less than 6mm of external diameter.
● Do not apply power before power line connection.
● Check power polarity.
● Tighten the terminal screw with 0.5 to 0.8N·m torque.
● Ground resistance should be less than 100Ω and ground it separately.
Battery Replacement
Please contact out distributor to replace battery. It may cause an explosion or a fire when improper battery is used.
+
+
24VDC
F.G.
-
-
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
4. Operate the product after supplying power to the product, input/output equipment, and load.
If operate product before supplying power, it may result in output error or malfunction.
5. Keep away from high voltage lines or power lines to prevent inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Make a required space around the unit for radiation of heat, and do not block ventilation openings.
7. Do not push the touch panel with a hard and sharp object or push the panel with excessive force.
It may result in fire or malfunction.
8. When skin is smeared with liquid crystal from the broken LCD, rinse with running water for over 15 minutes.
If it gets into the eyes, rinse eyes with running water for over 15 minutes and contact a doctor.
9. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
Altitude max. 2,000m
Pollution degree 2
Installation category II
V-46
Loading...