AutoFry MTI-10 Installation Manual

Models FFG-10 and MTI-10
Operator's Manual
MTI Form OP-0010 Rev. 005 5/98 E167653
A Patented Product of
Motion Technology, Inc.
6 Huron Drive
Natick, MA 01760
Telephone: (508) 653-0082
AUTOFRY Models FFG -10 and MTI-10 Operator's Manual
Table of Contents
Specifications iv Prepare electrical service 1 Prepare counter top 1 AUTOFRY Installation 2
Unpacking 2 Lea installation 3 Initial cleaning 4
Install charcoal filter 5
Install oil pot 6 Install heater box 6-5
Connect RTD 7 Connect thermocouple 7
Connect heater plug 7 Add liquid shortening 8 Install food exit chute 8 Install wire food basket 9 Power 10
Let's Get Cook/no 11
Starting the AUTOFRY 11 Begin cooking 12 During cooking 12 AUTOFRY shutoff 13
Additional KEYPAD functions 14
The COUNT button 14 The Stand-by button 15 Programming cook times 16
Recommended cleaning schedule 19
Daily cleaning 19 Weekly cleaning 20-21 Quarterly cleaning 22 Charcoal filter 23 Second filter 23 Semi-annual cleaninq and maintenance 24 Safety system test 24-25
Questions and Answers 26-28 Error Codes and Trouble Shooting Guide 29 Maintenance IOG 30-32
Wiring Diagrams 33-34
MTI FormOP-0010 Rev. 005 5/98 E167654
AUTOFRY Models FFG-10 and MTI -10 Operator's Manual
Information in this document is subject to change without notice and without incurring any obligations for the equipment previously or subsequently sold. No part of this document may be reproduced or trans mitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Motion Technology, Inc.
NO HOODS? NO VENTS? NO PROBLEM! Is a registered trademark of Motion Technology, Inc.
1999 Motion Technology, Inc. All rights reserved
MTI FormOP-0010 Rev. 005 5/98 E167654
AUTOFRY Models FFG -10 and MTI-10 Operator's Manual
Table of Figures
Figure 1 Re-set high limit 2 Figure 2 Install legs 3 Figure 3A Figure 3B Separate food entry chute 4 Figure 4 Filter cover plate 5 Figure 5 Figure 6 Oil pot installed 6 Figure 7 Install heater box assembly 6 Figure 8A Figure 8B Thermocouple plug 7 Figure 9 Install food exit chute 8 Figure 10A Figure 10B Basket rod and receiver clip 9 Figure 11 Completed installation 9 Figure 12A Figure 12B MTI -10 Fusable link and cable 20 Figure 13A Removable stack cover / fire damper 22 Figure 13B
Remove food entry chute 4
Charcoal filter 5
RTD plug 7
Basket rod and cam 9
FFG-10 Fire actuation cable 20
Fan section 22
MTI FormOP-0010 Rev. 005 5/98 E167654
ii
AUTOFRY Models FFG -10 and MTI-10 Operators Manual
Specifications
AUTOFRY Model FF6-10
Electrical Specifications:
208/240 ACV Single Phase Dedicated Grounded Circuit
3750 Watts
18Ampsat208ACV
15.63Ampsat240ACV NEMA 6-20 Plug ETL and NSF Listed BOCA - ES
AUTOFRY Model MTI-10 with RTD
Electrical Specifications:
208 ACV Single Phase Dedicated Grounded Circuit
3750 Watts 18 Amps NEMA 6-30 Plug UL, cUL and NSF Listed BOCA - ES
240 ACV Single Phase Dedicated Grounded Circuit
3750 Watts
15.63Amps
NEMA 6-20 Plug
UL, cUL and NSF Listed BOCA - ES
AUTOFRY Model MTI-10 with Thermocouple
Electrical Specifications:
240 ACV Single Phase Dedicated Grounded Circuit
4800 Watts
21Amps NEMA 6-30 Plug UL, cUL and NSF Listed BOCA - ES
Physical Specifications for All Models:
Dimensions:
Length 25-1/2" Width 27-1/2" Height 28-3/4"(with 4" legs) Clearances:
Sides and Back: 2" Top: 24" Min. Weight: 180Lbs. Materials: 304 Stainless Steel Shipping Dimensions: 32" x 32" x 32"
MTI Form OP-0010 Rev. 005 5/98 E167654
iii
AUTOFRY Models FFG-10 and MTI -10 Operator's Manual
1
AUTOFRY Models FFG-10 and MTI -10 Set-up and Installation
The AUTOFRY comes from the factory complete with everything you will need to start cooking with the exception of food and oil. By following these si mple instructions you can have your AUTOFRY installed and ready to earn profits for you in as little as 30 minutes.
Prepare electrical service. A licensed electrician in accordance with the National Electrical Code (NEC) and all local
codes must install electrical service. Do not remove or otherwise alter the factory supplied power cord or plug. Never attach the AUTOFRY to an extension cord. Consult the Identification Tag for equipment wattage and voltage.
Motion Technology, Inc. will not assume responsibility for any
injuries or equipment malfunctions resulting from non-
conforming electrical installations.
Prepare counter top.
Choose a counter top location that is sturdy, level, easily cleanable and fire resistant. Stainless steel, fire resistant plastic laminate or solid surface materials are acceptable. Never use a porous material to prepare food as bacterial contamination could result.
MTI FormOP-0010 Rev. 005 5/98 E167654
AUTOFRY Models FFG -10 and MTI-10 Operator's Manual
AUTOFRY Installation.
You will need assistance to position and install the AUTOFRY. The approximate weight of the unit is 180 pounds
Remove and save the packing materials.
Be sure to inspect the AUTOFRY. Your AUTOFRY has left the factory in perfect condition and has been packaged to withstand rugged travel. However, in the event that you observe damage to the AUTOFRY, you should contact the carrier immediately and report any damages. Be sure that you have your signed bill of lading.
Take out the removable components from inside the AUTOFRY.
4 adjustable legs
• " A 36" drain hose
• Food exit chute
• Wire food basket
• * Heater box assembly
• Oil pot
• Oil catch tray
* Check the red high limit re-set button on the bottom of the heater box
assembly by fully depressing it with the eraser end of a pencil. If the limit has been
tripped you will hear a "click" (see Figure 1).
MTI FomnOP-0010 Rev. 005 5/98 E167654
2
AUTOFRY Models FFG-10 and MTI -10 Operator's Manual
3
Charcoal filter removal and leg installation.
With the AUTOFRY still on its shipping pallet, tilt the unit backward and remove the
charcoal filter from the food exit cutout.
• Install two of the adjustable legs by rotating them clockwise to a hand tight fit into the front two leg plates located on the underside of the AUTOFRY.
Tilt the AUTOFRY forward and repeat the leg installation for the rear two legs (see Figure 2).
. Place on counter.
Carefully place the AUTOFRY on the counter
• Adjust the legs (as needed) to level the AUTOFRY.
Make sure that nothing is placed on top of the AUTOFRYwhich could obstruct the
exhaust system.
MTI FormOP-0010 Rev. 005 5/98 E167654
AUTOFRY Models FFG -10 and MTI-10 Operator's Manual
4
Initial Cleaning.
Wash the oil pot, wire food basket, oil catch tray and food exit chute
in warm soapy water followed with a clear water rinse.
• Remove the food entry chute by turning the food chute knob counterclockwise (see Figure 3A).
• Separate the two-piece food entry chute and wash in warm soapy
water followed with a clear water rinse (see Figure 3B).
Sanitize parts.
All parts must be sanitized in a quaternary ammonia or iodine solution at a
temperature of at least 75° F following the manufacturers label instructions.
• Re-assemble and re-install the clean dry parts.
MTI FormOP-0010 Rev. 005 5/98 E167654
AUTOFRY Models FFG -10 and MTI-10 Operator's Manual
5
Install Charcoal Filter
Remove the filter cover plate from the back interior wall of the cooking chamber by removing the two black plastic knobs securing the cover plate (see Figure 4).
• Remove the charcoal filter from the plastic bag with the flange facing down and facing you insert it into the tracks above the second filter (see Figure 5).
• Re-install the filter cover plate by turn ing the black plastic knobs clockwise to a hand tight fit. Verify that the word "TOP" on the filter cover plate is in the upper left-hand corner (see Figure 4).
Both the grease baffle and the second filter have small holes along the one side of the frame. These drain holes must be facing down in order for the filters to efficiently drain and clean the air (see Figure 5).
Sanitize interior.
All interior surfaces must be sanitized in a quaternary ammonia or iodine solution at a temperature of at least 75° F following the manufacturer's label instructions.
MTI FormOP-0010 Rev. 005 5/98 E167654
AUTOFRY Models FFG-10 and MTI -10 Operator's Manual
6
Install oil pot.
• Place the oil pot into the cooking chamber and install the oil pot bracket onto the oil pot flange mounted on the floor of the cooking chamber. Ensure that the drain valve is in the closed position (see Figure 6).
Experience has shown that an even light application of Kote® bran soil shield on the exterior surfaces of the oil pot will prove helpful when it is time to clean the oil pot. To order call 800-348-2976.
Install the heater box assembly.
MTI FormOP-0010 Rev. 005 5/98 E167654
Loading...