INSTALLATION AND OPERATION MANUAL
ICON-CP
Page 2
IMPORTANT SAFETY INFORMATION PRÉCAUTIONS DURANT UTILISATION
Read these instructions.1.
Keep these instructions.2.
Heed all warnings.3.
Follow all instructions.4.
Do not use this apparatus near water.5.
Clean only with dry cloth.6.
Do not block any ventilation openings. Install in accordance with the 7. manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, 8. stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. 9. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly 10. at plugs, convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.11.
Use only with the cart, stand, tripod, bracket, or table specified by the 12. manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when 13. unused for long periods of time.
Refer all servicing to qualified service personnel. 14. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
This appliance shall not be exposed to dripping or splashing water and 15. that no object fi lled with liquid such as vases shall be placed on the apparatus.
Plug this apparatus to the proper wall outlet and make the plug to be 16. disconnected readily operable.
Main plug is used as disconnected device and it should remain readily 17. operable during intended use. In order to disconnect the apparatus from the mains completely, the mains plug should be disconnected from the mains socket outlet completely.
WARNING:18. To reduce the risk of fi re or electric shock, do not expose this apparatus to rain or moisture.
An appliance with a protective earth terminal should be connected to a 19. mains outlet with a protective earth connection.
LISEZ ces instructions.1.
Tenez ces instructions.2.
Notez tous les avertissements.3.
Suivez toutes les avertissements.4.
N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.).5.
Nettoyez seulement avec une étoffe sèche.6.
Ne bloquez aucuns troux de ventilation. Installez en accord avec 7. les instructions du manufacturier.
N’installez près aucunes sources de chaleur comme radiateurs, registres 8. de chaleur, fours ou les autres équipements (y compris amplifi cateurs) qui produisent la chaleur.
Ne défaites pas le but de sécurité de la fi che polarisée ou base-type. 9. Une fi che polarisée a deux tranchants avec un plus large que l’autre. Une fi che de base type a deux a deux tranchants et une troisième pointe de base, le tranchant large ou la troisième pointe est fourni pour votre sécurité. Si la fi che donnée ne conforme pas votre prise de contact, consultez un électricien pour remplacement de la prise de contact obsolète.
Protegez le cordon de secteur contre être marchée dessus ou pincez 10. en particulier aux fi ches, aux douilles de convenance, et au point où ils sortent de l’appareil.
Seulement utilisez attachements/accessoires spécifi és par le 11. manufacturier.
Utilisez seulement avec un chariot, un stand, un trépied, un support 12. ou une table indiquée par le manufacturier, ou vendue avec l’appareil. Quand un chariot est utilisé, faites attention en déplaçant la combinaison d’appareil/chariot pour éviter de se déséquilibrer.
Arrachez la fi che du dispositif durant éclair et orage ou 13. quand pas utilisé pour longues périodes de temps.
Référez au personnel qualifi é de service pour toutes 14. réparations. La réparation est donnée quand le système a été endommagé à n’importe façon, par exemple un fi l ou une fi che endommagé(e) de la source d’alimentation. Avoir été exposé à pluie ou humidité, n’opère pas normalement, ou avoir été tombé.
L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures 15. et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé sur l’objet.
Branchez l’appareil à une source appropriée et faire que la prise à 16. débrancher soit facilement accessible.
La prise du secteur ne doit pas être obstruée ou doit être facilement 17. accessible pendant son utilisation. Pour être complètement déconnecté de l’alimentation d’entrée, la prise doit être débranchée du secteur.
AVERTISSEMENT: 18. Pour éviter le risque d’incendie ou de chocs électriques, ne pas exposer cet appareil à la pluie ou à l’humidité.
Un appareil avec la borne de terre de protection doit être connecté au 19. secteur avec la connexiion de terre de protection.
PAGE 2
ICON-CP MANUAL
Page 3
INTRODUCTION AND CONTENTS
ICON-CP
The ICON control panel is both elegant and ergonomic to suit today’s modern installations.
The ICON CP controls a number of Australian Monitor products & will also be compatible with a number of new products making the unit fl exible and future proof.
The ICON control panel is programmable to allow for a host of confi gurations and control options all from the one control panel.
INTRODUCTION 3
ICON-CP AND REVOLUTION SERIES 4
ICON-CP AND AMD100-200 5
ICON-CP AND IN600 6
DIMENSIONS 7
Revision 1.2 August 2010
WARNING!
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH
AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES
CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT, FULLY INSERT.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning fl ash with arrowhead symbol,
within an equilateral triangle, is intended
to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of
suffi cient magnitude to constitute a risk
of electric shock to persons.
WARNING: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
ICON-CP MANUAL
Rating plate and caution marking are marked on the back enclosure of the apparatus
PAGE 3
Page 4
ICON-CP AND REVOLUTION SERIES
ICON-CP Control Panel
The Revolution series control panels (ICON-CP) have two banks of DIP switches on the rear of the control panel. The fi rst bank of switches labeled SW1 allows the user to address the panel for RS485 communications. The second bank of switches allows the user to set up the LED functions for the remote panel.
SW1:
RS485 addresses 1-240 are allowed. With any other address the unit will blink its error LEDs.
ABC
SW2 Func
fail or be broken it could simply be swapped out with a unit set to the same address. All control panels are constantly polling the RS485 network for status. This will allow the user to update settings via 3rd party, other control panels or the software GUI and have all panels constantly up to date.
Each RS485 port on the Revolution series allows you to run up to 20 control panels to a maximum distance of 500 metres. With each unit featuring two RS485 ports, this allows the AV Revolution to run up to 40 ICON-CP’s on two separate 500m runs. The 500m limitation of the control panels is due to power loss over distance and not RS485 limitations therefore if lengths longer than 500m are required you need to inject power locally for greater distances.
D
1248163264
128
SW1 Address
SW2
A: ON = LED brightness varies based on ambient light, OFF = Fixed Brightness
B: ON = Low brightness (if switch A is on fi xed brightnes mode), OFF = Normal Brightness
C: Unused on Revolution series
D: Unused on Revolution series
The ICON-CP control panels do not hold any project data so if a panel was to
PAGE 4
ICON-CP MANUAL
Page 5
The ICON-CP can be used to control certain functions of the AMD100/200.
The set up the control panel all you need to do is address the panel on SW1. Switch 1-8 represent a binary address. For example to address it to ID1 all you need to do is have number 1 on, to address it to 3 have switch 1 and 2 on.
SW2 C and D do not do anything, A and B adjust the LED settings of the panel. With switch A high ambient light adjustment will be turned on. With switch B on, low brightness mode will be activated. Only one switch should be up at a time.
ID 1: (Switch 1 On)
In this mode the fi rst 5 buttons act as a source select (1-4 and off)
The 6th button acts as a mute control
Buttons 7 and 8 are volume up and volume down for the BGM source
NOTE: BGM Off deselects all the BGM input.
BGM Mute toggles and maintains the selected BGM source for easy unmuting.
ICON-CP AND AMD100-200
1. BGM 1
2. BGM 2
3. BGM 3
4. BGM 4
5. BGM Off
6. BGM Mute
7. BGM Vol +
8. BGM Vol -
ID 2: (Switch 2 On)
In this mode the panel acts as 6 individual volume controls.
The fi rst 6 buttons pick the volume you want to control and the bottom two buttons are volume up and volume down.
ID 3: (Switch 1 and 2 On)
This mode is the same as two but controls different sources. Note, this is will work on AMD200 only.
1. Mic\Line 1
2. Mic\Line 2
3. Mic\Line 3
4. Mic\Line 4
5. BGM
6. Master
+ Volume
- Volume
1. Mic\Line 5
2. Mic\Line 6
3. Mic\Line 7
4. Mic\Line 8
5. BGM
ICON-CP MANUAL
6. Master
+ Volume
- Volume
PAGE 5
Page 6
ICON-CP AND IN600
With the ICON-CP’s DIP switch bank 2(FUNC) set with D on the ICON-CP will control the AMAV IN600.
The control parameters are fi xed to three different confi gurations. These are:
1. Source 1 (DVD1)
2. Source 2 (DVD2)
Address ID 1: (Switch 1 On)
With this setting you get control over selection of the sources and also volume control of the source mixer. When a source is selected after already being active the unit will switch the source to “Off”
Address ID 2: (Switch 2 On)
With this setting you have control over turning the projector on and off. You can also turn each microphone on by triggering its mute control. The volume control will control the mic mixer level on the unit.
Address ID 3: (Switch 1 and 2 On)
With this setting selected you have the exact same controls as ID2 except the microphone mute controls are inversed so that the active state will have the microphone off.
Powering the ICON-CP
The ICON-CP remote panels will need to be externally powered when being used with the IN600. As these units have RJ45 looped in and outs we now provide a 24V DC power injector that simply has a data in and a P+Data out. It is recommended that this unit be placed close to the ICON-CP, all you need to do is run from the IN600 into the power injector then out to your run of remote panels.
3. Source 3 (AUX1)
4. Source 4 (AUX2)
5. Source 5 (PC1)
6. Source 6 (PC2)
7. Source Volume Up
8. Source Volume Down
Address ID 1: (Switch 1 On)
1. Projector On
2. Projector Off
3. Mic 1 On
4. Mic 2 On
5. Mic 3 On
6. Mic 4 On
7. Mic Volume Up
Connecting to the IN600
When wiring the ICON-CP panels we suggest simply using premade cables if possible or if terminating your own to follow one standard the whole way that will allow your connections to be pin to pin from the start to the end.
The IN600 has a terminal block for the RS485 bus. The pin out needed to connect the ICON-CP to the IN600 is below:
Data line A = Pin 3 of the ICON-CP
Data line B = Pin 6 of the ICON-CP
Gnd line = Pin 2 of the ICON-CP
White/Green 1
Green 2
Shown with
locking clip
facing
White/Orange 3
Blue 4
White/Blue 5
Orange 6
White/Brown 7
Brown 8
CABLE
8. Mic Volume Down
Address ID 2: (Switch 2 On)
1. Projector On
2. Projector Off
3. Mic 1 Off
4. Mic 2 Off
5. Mic 3 Off
6. Mic 4 Off
7. Mic Volume Up
8. Mic Volume Down
Address ID 3: (Switch 1 and 2 On)
PAGE 6
568A configuration
ICON-CP MANUAL
Page 7
DIMENSIONS
ICON-CP MANUAL
PAGE 7
Page 8
ENGINEERED BY AUSTRALIAN MONITOR
Address: 1 Clyde Street, Silverwater, Sydney NSW 2128 Australia. Private Bag 149, Silverwater NSW 1811 ABN 78 001 345 482 Website: www.australianmonitor.com.au International enquiries email: international@australianmonitor.com.au
DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www.hillssvl.com.au
NSW QLD ACT WA VIC SA NZ P: 02 9647 1411 P: 07 3852 1312 P: 02 6260 4544 P: 08 9204 0200 P: 03 9890 7477 P: 08 8408 8300 P: 09 415 9426 E: nsw@hillssvl.com.au E: qld@hillssvl.com.au E: act@hillssvl.com.au E: wa@hillssvl.com.au E: vic@hillssvl.com.au E: sa@hillssvl.com.au E: sales@hillssvl.co.nz
Loading...