Australian Monitor DigiPage User Manual

Page 1
Australian Monitor
INSTALLATION SERIES
Clever Features, Contractor Friendly
DigiPageJr
Multizone Paging
&
Program Selection
System
&
Operation
Manual
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 PAGE ENABLE
TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE
PROG1 PROG1 PROG1 PROG 1 PROG 1 PROG1 PROG 1 PROG1
BASS BASS BASS BASS BASS BASS BASS BASS
PROG2 PROG 2 PROG 2 PROG2 PROG 2 PROG2 PROG 2 PROG2
PROG3 PROG 3 PROG 3 PROG3 PROG 3 PROG3 PROG 3 PROG3
PROG PROG PROG PROG PROG PROG PROG PROG
MIC MIC MIC MIC MIC MIC MIC MIC
PROG4 PROG 4 PROG 4 PROG4 PROG 4 PROG4 PROG 4 PROG4
55555555
44444444
66666666
33333333
77777777
22222222
88888888
11111111
99999999
00000000
10 10 10 10 10 10 10 10
MASTER 1 MASTER 2
MASTER 3
MASTER 4 MASTER 5 MASTER 6 MASTER 7 MASTER 8
ZONE1
ZONE2
ZONE3
ZONE4
ZONE5
ZONE6
ZONE7
ZONE8
Australian Monitor
INSTALLATION SERIES
ON
POWER
Page 2
AUS, EUR, USA Copyright 20th Nov 2003 Rev A: 20th Nov 2003 Rev B: 11th Aug 2004 Rev C: 14th Nov 2006
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Internal Revision Info Rev 1 25/06/03 Rev 2 09/10/03 Rev 3 05/11/03 Rev 4 06/11/03 Rev 5 20/11/03
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operation and main­tenance (servicing) instructions in the literature accompanying the appliance.
WARNING !
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
Australian Monitor
INSTALLATION SERIES
2
Caution:
To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade ex­posure.
To prevent electric shock, match wide blade of plug to wide slot, fully insert.
Page 3
CONTENTS
Page
1. Introduction 4
2. Front Panel 5
3. Back Panel 8
4. Installation 11
5. Setup 14
6. Linking Two DigiPageJr Systems 16
7. Paging Station 18
8. Accessories 20
9. Troubleshooting Guide 20
10. Block Diagram 21
11. Dimensions 22
12. Specifications 23
3
Australian Monitor
INSTALLATION SERIES
Page 4
1. INTRODUCTION
The Australian Monitor Installation Series DigiPageJr is a two rack unit multizone paging and source selection system that offers unprecedented flexibility for multizone paging & source routing applications. Four program inputs are available to each of eight zone outputs. The DigiPageJr is also expandable to 16 zones via a simple link cable to a second unit. Paging stations are available in 8 zone and 16 Zone models allowing paging into any individual zone, any combination of zones or All Call. There is also the ability to have one Paging Station as a priority paging station. The Paging stations connect via an inexpensive and industry standard CAT5 cable network. An overall priority input is also provided for emergency or evacuation signals. The DigiPageJr is powered by an (included) external plug-pack power supply or via 24VDC. The DigiPageJr is a versatile and well featured product that provides a simple solution to the complex applications of multizone paging and source routing.
We thank you for choosing Australian Monitor Installation Series and as with all our products, the DigiPageJr offers clever features and is contractor friendly.
Australian Monitor
INSTALLATION SERIES
4
Page 5
2. FRONT PANEL
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE
PROG1 PROG 1 PROG 1 PROG1 PROG 1 PROG1 PROG 1 PROG1
BASS BASS BASS BASS BASS BASS BASS BASS
PROG2 PROG 2 PROG 2 PROG2 PROG 2 PROG2 PROG 2 PROG2
PROG3 PROG 3 PROG 3 PROG3 PROG 3 PROG3 PROG 3 PROG3
PROG PROG PROG PROG PROG PROG PROG PROG
MIC MIC MIC MIC MIC MIC MIC MIC
PROG4 PROG 4 PROG 4 PROG4 PROG 4 PROG4 PROG 4 PROG4
55555555
44444444
66666666
33333333
77777777
22222222
88888888
11111111
99999999
00000000
10 10 10 10 10 10 10 10
MASTER 1 MASTER 2
MASTER 3
MASTER 4 MASTER 5 MASTER 6 MASTER 7 MASTER 8
Expanded view
PAGE ENABLE
ZONE5
ZONE1
ZONE6
ZONE2
ZONE7
ZONE3
ZONE8
ZONE4
Australian Monitor
INSTALLATION SERIES
7 9
8
3
ON
POWER
1
2
4
5
6
5
Australian Monitor
INSTALLATION SERIES
Page 6
The controls detailed below (1-6) apply to each output zone, as indicated by ZONE 1 .. ZONE 8 on the front panel.
1 PROG 1-4:
This series of program switches (PROG 1- PROG 4) allows any one of the connected program sources to be switched to this zone. Note that these are mechanically interlocking switches: only one program may be selected at a time. Program inputs may be mic or line, see Back Panel on page 8.
2 MASTER 1-8:
This control adjusts the overall output level of the zone.
3 TREBLE
The treble control has 10dB of cut or boost at 10kHz. The treble control affects the entire zone.
NOTE: Note that ‘center ’ is to the right (3 o’clock), not the top (12 o’clock).
4BASS
The bass control has 12dB of cut or boost at 100Hz. The bass control affects the entire zone.
NOTE: Note that ‘center ’ is to the right (3 o’clock), not the top (12 o’clock).
5 PROG
This control adjusts the overall level of the selected program source into the zone.
NOTE: To balance the differing levels of each program input, the program trim
controls on the Back Panel should be used (see Back Panel and Setup sections)
6PAGE
This control adjusts the paging mic level into the zone.
Australian Monitor
INSTALLATION SERIES
6
Page 7
Located at the right-hand end of the unit, these controls affect all zones.
7 PAGE ENABLE
This switch allows the zone to be included in or isolated from the paging function. You may want to do this when a zone is an area such as a function room that occasionally may need to be isolated from paging.
8ON
This LED indicates there is power to the unit.
NOTE: When 24VDC emergency power is supplied this LED will always be on.
9 POWER
This switches power from the power supply (included ).
NOTE: When 24VDC emergency power is supplied, the unit is on regardless of
the switch position.
7
Australian Monitor
INSTALLATION SERIES
Page 8
3. BACK PANEL
MASTER
SLAVE
7
8
ENGINEERED BY AUDIO TELEX COMMUNICATIONSPTY LTD SYDNEY AUSTRALIA
POWER IN
VDC
+24V
6
4b
1
PROGPROG PROGPROG
GAINGAIN
ZONE OUTPUTS
6
5
MICMIC MICMIC
4
LINELINE LINELINE
3
21
23
CAT 5CAT 5CAT 5CAT 5 RUN 1RUN 2RUN 3RUN 4DATALINK
4a
5
PROG LINKS
INPUTOUTPUT
SUMTONE GEN
INPUTOUTPUT
SUM IN
EVAC
GROUND
ALERT
GROUND
COMMON
+ 24V DC
LEVELLEVEL
8
7
1 PROG 1 - 4 Input Section
LINE
The pair of RCA sockets accepts unbalanced line level inputs. Stereo signals are internally summed to mono.
PROG 1PROG 3 PROG 2PROG 4
GAINGAIN
MIC
The XLR socket accepts balanced microphone level signals.
PROG GAIN
PIN 2
HOT
+
PIN 3 COLD
PIN 1 GND
-
FEMALE XLR
The trimpot controls the input gain of BOTH the balanced and unbalanced program inputs. In a Master/Slave configuration, these also control program linked inputs. (see Linking Section)
2 ZONE OUTPUTS
There is a balanced XLR line level output for each zone.
PIN 1 GND
MALE XLR
NOTE: If connecting to an unbalanced input, the negative pin (3) should not be
connected to ground but left floating.
NOTE: When operating as a slave unit, outputs labelled 1 to 8 will correspond to
zones 9 to 16, respectively. (see Linking Section)
PIN 2
HOT
+
PIN 3 COLD
-
Australian Monitor
INSTALLATION SERIES
8
Page 9
3 EUROBLOCK CONNECTOR
24V DC / GROUND
This input pair is for connection to a 24VDC emergency power supply and is not switched by the front panel power switch.
NOTE: The 24V DC input does not provide a
trickle-charge facility.
ALERT/EVAC/COMMON
These connections are used to trigger the internal tones. Only one tone can be triggered at a time. Triggering occurs by connecting the ALERT or EVAC terminal to COMMON.
GROUND/SUM IN
This is an unbalanced line level input which may be used for emergency priority signals. It feeds all zone outputs independent of output level settings and page enable status.
NOTE: Signal on the SUM IN will cause other signals
to be muted.
NOTE: The muting by the SUM IN remains active
for 3sec after the input signal is removed.
SUM INPUT LEVEL
This recessed trimpot sets the level of the sum input.
TONE GEN OUTPUT LEVEL
This recessed trim pot controls the output level of the tones and the pre-annouce chime.
4a CAT 5 RUN 1
This RJ45 input accepts the CAT5 cable coming from the priority paging microphone station. See ‘Installation’ on page 12 for more information. If you would like to have a paging station set as a priority over all other paging stations, then it must be connected to this RJ45 socket and no other stations may use this connector or the run that it is on. The paging station also needs to be set up as a priority station (see Paging Station section).
4b CAT 5 RUN 2-4
These RJ45 inputs accept the CAT5 cables coming from the Paging Stations. See page 12 for more information.
NOTE: These are Ethernet connections.NOT
NOTE: Connecting and disconnecting these inputs while the unit is on may
cause the unit to lock up requiring system power to be cycled.
Australian Monitor
INSTALLATION SERIES
9
Page 10
5 PROG LINKS
These RJ45 sockets allow linking of the program sources when using a Master/Slave configuration. (see ‘Linking Section’ on page 18)
NOTE: These are Ethernet connections.NOT
6 DATA LINK
This socket is used to link two units in a Master/Slave configuration. (see ‘Linking Section’ on page 18)
NOTE: These are Ethernet connections.NOT
7 MASTER/SLAVE
This switch is used when linking 2 units in Master/Slave configuration. (see ‘Linking Section’ on page 18)
8 POWER IN VAC
This 2.1mm power socket accepts the 20VAC power supply provided with the unit.
Australian Monitor
INSTALLATION SERIES
10
Page 11
4. INSTALLATION
OVERVIEW
The DigiPageJr features extensive flexibility in the range of input sources that it can accommodate. In addition, the zone outputs may be used to feed power (booster) amplifiers, mixers, mixer amplifiers etc. It is therefore important to think about the interfacing of the DigiPageJr with the other equipment if optimum performance and system stability is to be achieved. Use the Back Panel and Specifications sections of this manual to assist with system design.
NOTE: XLR CONFIGURATION
PIN 2
HOT
+
PIN 3
COLD
-
FEMALE XLR
PIN 1 GND
PIN 1
GND
PIN 2
MALE XLR
When wiring the outputs on the DigiPageJr as
HOT
+
unbalanced, Pin2 should be used as hot and Pin1
PIN 3 COLD
as ground. Pin3 should be left open and NOT
-
shorted to Pin1.
NOTE: If installing and terminating CAT5 cable is new to you, please take note of the
various points that follow. As the CAT5 cabling for the DigiPageJr carries voltage, damage could occur if your pin-pin connections are not made correctly.
CABLE INSTALLATION FOR PAGING STATIONS
Four RJ45 ports (labelled ) are provided for connection to the DigiPageJr Zone
CAT 5 RUN 1-4
Paging Stations. The four ports allow for easy cable infrastructure, as CAT5 runs can be of differing lengths depending on the installation and the number of paging stations connected.
In planning the installation, the following rules apply:
Up to 4 Paging Stations may be connected to each of the four CAT5 runs.
!
Connections along the runs must be in a daisy-chain configuration. It is acceptable to
!
create a short branch (eg, from a wall outlet to a paging station). The maximum length of the branch is 10m. The following table indicates the maximum distance allowable for a CAT5 run on a
!
single port. For greater distances or more paging stations, see page 14.
!
The last unit on a run must be terminated. This is done by moving a jumper on the
!
paging station or remote unit. See ‘Paging Station’ on page 18 or ‘Remote Control Panel’ on page 21.
NUMBER OF DEVICES MAX DISTANCE ON SINGLE CAT5 RUN TO END UNIT (m/ft)
1xPaging Station 250m/820ft 2xPaging Staions 125m/410ft 3xPaging Stations 80m/260ft 4xPaging Stations 62.5m/205ft
TABLE #1
11
Australian Monitor
INSTALLATION SERIES
Page 12
INSTALLATION OF A PRIORITY PAGING STATION
The following rules apply for connecting a paging station as a priority paging station to over ride all other paging stations:
The paging station must be enabled as a priority paging station (see Paging Station
!
section on page 20). The paging station that is used as a priority station must be connected to CAT5 RUN 1.
!
The only paging station that can be connected to CAT5 RUN 1 is the priority paging
!
station. No other paging stations may share that CAT5 RUN.
NOTE: These are Ethernet connections.NOT
CAT5 CABLE
CAT5 cable is the blue cable commonly used for data installations (other colours do exist). It consists of four twisted pairs of wires: this is why it is often referred to as UTP (Unshielded Twisted Pair). The most readily available cable uses solid conductors, like telephone wire. Cable with stranded conductors is available, and is more flexible.
CAT5 TERMINATION
Pre-wired CAT5 cable comes in two configuration standards, 568A and 568B. It is advisable to carry a good pre-wired cable for fault-finding. Both configurations will work with the DigiPageJr provided both ends have the same configuration. Be careful not to use a crossover cable which has one configuration at one end and the other configuration at the other end.
Ensure that the RJ45 connectors are suited to the cable used (solid or stranded) and that the correct crimp tool is used.
When wiring connectors, 568A standard wiring is recommended (see diagram).
Shown with
locking clip
facing
White/Green 1
Green 2
White/Orange 3
Blue 4
White/Blue 5
Orange 6
White/Brown 7
Brown 8
568A configuration
CABLE
Ground Power Ground Busy­Busy+ Priority Data/Voice+ Data/Voice-
NOTE: CAT5 cable consists of four pairs of wires: it is not sufficient to simply wire the two
ends pin for pin, ignoring pairing.
POWER REQUIREMENTS
The DigiPageJr can operate from the plug pack supplied and/or a separate 24V DC power supply.
A NOTE ABOUT GROUNDING: It may be necessary in some circumstances to ground the DigiPageJr to eliminate noise in the system. This can be done using the negative terminal of the 24VDC IN euro connector or by making sure that the chassis is electrically connected to the equipment rack (which should be grounded).
Australian Monitor
INSTALLATION SERIES
12
Page 13
EXTENDING CAT5 CABLE RUN DISTANCES & ADDING MORE PAGING STATIONS
The maximum distances quoted in the Table #1 are due to DC current limitations, not data transmission limitions. If distances greater than these are required, the paging stations can be locally powered. This will extend the maximum distances to 1000m per CAT5 RUN. Alternatively, if more than 4 paging stations are required on a single run, local powering can be used. This will increase the maximum number of paging stations on a single CAT5 RUN. Use a 12VDC supply connected as
regulated
pin1 (white/green in CAT5)- GROUND
pin2 (green in CAT5) - +12V Disconnect incoming +V, but not ground. The 12V supply should be rated at 150mA per microphone being powered. For further information email help@audiotelex.com.au.
TONE GENERATOR INPUTS
Tones may be triggered by closing a switch or relay contact between the selected tone trigger input and common. These trigger inputs are 5V TTL and may alternatively be triggered by pulling the desired input low referenced to the COMMON.
NOTE: The maximum voltage on these inputs must not exceed 5.5V
PRE-ANNOUNCE CHIME
The only internal setup that is available in the DigiPageJr is for the configuration of the chime tone that sounds in each zone. The unit comes shipped with the chime enabled in all zones. A link can be found on the main board just behind the zone control boards (see diagram). To disable the chime to a particular zone, remove the link. To re-enable the chime, replace the link.
NOTE: Remember to wait for the chime to finish before speaking. Note that when
the chime is disable it will still activate but will not be heard so you must still wait approximately 1 sec before speaking after press the page button.
Zone 3
Zone 5
Zone 7
Zone 8
Zone 6
Zone 4
Zone 2
Zone 1
13
Australian Monitor
INSTALLATION SERIES
Page 14
5. SET UP
The inputs of the DigiPageJr can accommodate a wide range of sources including active paging stations, dynamic microphones, DVD and CD players, tuners and cassette players. The zone outputs may be used to drive power (booster) amplifiers,mixers, or mixer amplifiers.
Each installation will require setting the appropriate relative mix of levels between paging and program sources for each zone and balancing between the zones.
Because of the variation in levels between the possible sources, DigiPageJr offers a number of gain stage adjustment so you can set the correct levels for your application.
Also consider what the outputs are driving.
Setting up correct gain structure through the whole system is important to achieve optimal results.
The following step by step procedure has been devised to assist during the setup process. When the DigiPageJr was shipped to you from the factory it was set up in a particular way. In the following procedure it is essential that you are starting from these initial settings.
Program Input Gain Controls - half (12 o’clock)
!
Master Volume - off
!
Mic level - half (3 o’clock)
!
Prog level - half (3 o’clock)
!
12 o’clock
3 o’clock
Step by step setup
Confirm the initial settings of DigiPageJr.
Choose a zone that is conveniently located near to the DigiPageJr or further away if you feel you need the exercise.
This will be the referred to as “TEST ZONE”. Ensure that all amplifiers connected to the DigiPageJr are set to provide required sound levels with a line level input signal.
Choose a consistent program source, eg CD or tuner. This will be the referred to as “TEST PROG”.
1. Select TEST PROG in the TEST ZONE [front PROG 1-4]. Set the MASTER volume in the TEST ZONE to half way.
2. Adjust the rear PROG GAIN for the TEST PROG input to achieve the required sound level in the TEST ZONE.
3. Select PROG TEST in all other zones.
4. Bring up the MASTER volume in all other zones and check for required sound levels.
5. Make a test page to the TEST ZONE and check the level relative to the program level.
6. Adjust the page level as desired [front panel PAGE].
Australian Monitor
INSTALLATION SERIES
14
Page 15
7. Balance the other program sources in the TEST ZONE [rear panel PROG GAIN]
8. Apply the front panel settings from TEST ZONE to all other zones.
9. Using the front panel controls only, set the individual zones to your preferred settings
a. Set balance between prog/page b. Set Eq c. Set final master level
NOTE: A full discussion of setting up a complex system with correct gain structure is
beyond the scope of this manual. The procedure above assumes that the installer has correctly set up external equipment connected to DigipageJr prior to initiating the set up procedure.
15
Australian Monitor
INSTALLATION SERIES
Page 16
6. LINKING TWO DIGIPAGEJr SYSTEMS
NOTE: There are two series of DigiPage product available, the DigiPage and the
DigiPageJr. Use only DigiPageJr series paging stations with DigiPageJr and only DigiPage series paging stations with DigiPage.
DigiPageJr is fully expandable to form a 16 zone paging system by the simple linking of two units. One DigiPageJr is then designated the master unit, driving zones 1-8, with the other slave unit driving zones 9-16. The following settings and connections are required to form a linked DigiPageJr system.
The DigiPageJrM16 paging station must be used to access all zones. The DigiPageJrM8 can also be used but will only access zones 1 to 8
White/Green 1
Green 2
White/Orange 3
Blue 4
White/Blue 5
Orange 6
White/Brown 7
Brown 8
568A configuration
PROG 1 PROG 2 PROG 3 PROG 4 NC NC GROUND GROUND
CABLE
Program Source Wiring
MASTER/SLAVE
This switches the unit from master (switch in) to slave (switch out). When set as master the unit control zones 1 to 8. When set as slave the unit controls zones 9 to 16.
This switch should only
be operated when the unit is powered off.
DATA LINK
This link is essential. Use a pre-wired CAT5 patch lead. The maximum cable length for the data link cable is 10m, but note that the PROG LINKS cable length is limited to 0.5m (see below).
NOTE: Maximum data link cable length is 10m
NOTE: These are Ethernet connections.NOT
Australian Monitor
INSTALLATION SERIES
16
Page 17
PROG LINKS
Program sources can be sent to the slave DigiPageJr by connecting the PROG LINKS OUTPUT on the Master unit to the PROG LINKS INPUT on the Slave unit. This simplifies connection of sources as all 4 sources can be sent from the master to the slave via 1 CAT5 cable avoiding the need for Y-cables The PROG TRIM on the slave unit operates independently of the master unit. The PROG TRIM on the slave unit should be set to the same position as on the master. Use a pre-wired CAT5 patch lead. The maximum cable length for the program source link cable is 0.5m. However this cable should be kept as short as possible because it is carrying audio signal.
NOTE: If PROG LINKS is not used, it is possible to use completely different program
sources in zones 1-8 to zones 9-16.
NOTE: Maximum prog link cable length is 0.5m
PRIORITY PAGING STATION
If a priority paging station is being used in a linked 16 zone system it must be connected to CAT5 RUN 1 of the unit.master
17
Australian Monitor
INSTALLATION SERIES
Page 18
7. PAGING STATION
DigiPageJrM16
Introduction
The Australian Monitor Installation Series DigiPageJrM8 and DigiPageJrM16 Paging Stations are 8 and 16 zone paging stations complete with a slimline gooseneck paging microphone. The Paging stations are designed to be used with the DigiPageJr Zone Paging & Source Selection System and will allow paging into any individual zone, any combination of zones or All Call to all zones. LED indicators provide the user with visual feedback of the zones being paged or if the sytem is busy. Label space is provided on the Paging Station, which also provides a microphone gain control. Connection to the DigiPageJr is via low cost CAT 5 cable and as with all Australian Monitor installation products, the Paging Station provides an elegant solution at a contractor friendly price.
1 ZONE select
DigiPageJrM8
Controls
115.0mm
DigiPageJrM16
Australian Monitor
INSTALLATIONSERIES
These buttons allow selection of zones for paging. When selected, the adjacent LED glows green. Pressing the button again deselects the zone. The area next to the button is for labelling the zone. Selecting a zone does not instigate paging. See 4. ZONE PAGE.
178.0mm
Base Plate
section
Australian Monitor
INSTALLATION SERIES
1
BUSY
CLEAR
ALL PAGE
ZONE PAGE
6
2. CLEAR
5
This button clears all the selected zones.
3. ALL PAGE
This button pages to all zones. It is momentary so must
2
be held while talking into the microphone. It activates the microphone and mutes the program sources. It does NOT clear the current zone selection
3
configuration so the paging station will return to its previous state (selected zones) once the ALL PAGE
4
NOTE: Remeber to wait 1 sec for the pre-announcechime to finish.
button is released.
4. ZONE PAGE
This button pages to the current zone selection configuration as indicated by the ZONE select LEDs see 1 above. The zones being paged have their program sources muted and the microphone becomes active. If no zones are selected the system will still show as busy when this button is pressed.
NOTE: Remeber to wait 1 sec for the pre-announcechime to finish.
5. BUSY
This LED glows when the network or system is busy. This can be caused by the local paging station (you are making a page) or by another paging station. Paging is not possible while the system is busy, however zone selections can still be made.
18
Page 19
Installation and Setup
NOTE: There are two series of DigiPage product available, the DigiPage and the
DigiPageJr. Use only DigiPageJr series paging stations with DigiPageJr and only DigiPage series paging stations with DigiPage.
The CAT5 cable connects to the RJ45 socket on the rear panel of the paging station. This socket is a NEUTRIK connector designed to be used with the XLR style housing (model
TM
NE8MC) to improve reliability. Normal RJ45 connectors can also be used.
Plugging and unplugging the cable while the system is powered up may result in the system locking up and is not recommended. If this should happen, reset the DigiPageJr by switching off, then on.
6 GAIN
To accommodate different speech levels, there is a gain control on the base of the DigiPageJrM. This ships set to minimum and may be adjusted to suit. Increasing this control too far may cause the paging station to distort if loud or close speech levels are encountered. Caution should be used if trying to achieve high gain levels for distant or lectern speech styles as feedback may occur.
7 TERMINATING
In an RS485 network (of which the DigiPageJr is part of) it is important to terminate the last device in each CAT5 RUN. A jumper is provided for the data/voice transmission to be terminated if that Paging Station is at the end of a CAT5 RUN (see diagram). Shipped as unterminated.
8 PRIORITY
If a Paging station is being used as a priority over all other Paging Stations then the following rules apply The Priority Paging Station must be connected to CAT5 RUN 1 No other Paging station may be connected to CAT5 RUN 1 The Priority Paging Station must be set as priority by moving the jumper (see diagram). Shipped no priority set.
NOTE: When making changes be sure to power off and disconnect .
Gain Pot
(accessible through base plate)
(shown with Priority Enabled)
8
Data/Voice
7
(shown as terminated)
19
Australian Monitor
INSTALLATION SERIES
Page 20
8. ACCESSORIES
8 zone Paging Station Cat No. DPJR8M 16 Zone Paging Station Cat No. DPJR16M Punch down tool Cat No. DPPDT Black System Input Plate Cat No. DPRIPB White System Input Plate Cat No. DPRIPW Black Standoff surface mount Box Cat No. DPRMSMBB White Standoff surface mount box Cat No. DPRMSMBW Cat5 Cable tester Cat No. ATC-C5CT
NOTE: The paging stations for the DigiPageJr are different to the DigiPage and
cannot be mixed. The same applies to DPRM’s which cannot be used with the DigiPageJr.
9. TROUBLESHOOTING GUIDE
Trouble
DigiPage System
No response to controls
Poor signal to noise ratio
All Call works but Zone Page does not
Paging locked up
Paging Station
LED’s chase
Inconsistent operation
Mains brownouts or incorrect connection of devices may cause processor to lock-up
Incorrect system gain structure
Lack of system ground
Main unit set to slave
Priority paging station in CAT5 RUN2,3 or 4
Initailisation (boot) sequence
Cable too long
Cable fault
Likely Cause
Cycle power on the DigiPageJr
-Check settings of all equipment
-Revisit Step-by-Step Setup Procedure
See Grounding in Installation section
Set main unit master/slave switch to master (switch in)
Plug Priority paging station into CAT5 RUN1 only
Normal operation when power is applied
See Installation section
-Check cable.
-Check Paging Station with good cable at DigiPage
Remedy
Emits high-pitch whine
Australian Monitor
INSTALLATION SERIES
Last station on run not terminated
Station lock-up due to connection while system is live
20
Terminate the paging station. See Paging Station on page 20
With all Paging Stations connected, cycle power on the DigiPageJr
Page 21
10. BLOCK DIARGRAM
ZONE OUPUT
+6dB
ZONE1
ZONE2
ZONE3
EQ
1 OF 8 ZONES
ZONE4
ZONE5
PAG E
ZONE6
ENABLE
CONTROL
ZONE7
ZONE8
PROG LINK OUT
PROGRAM
SELECTION
-43dB
LINE
PROG
SWITCHES
-43dB
+6.5dB
OFF
+13.5dB
-33dB
0dB
+6.5dB
+13.5dB
PAGE
OFF
INTERLOCKING
MECHANICALLY
P1
P2
P3
P4
PWM
DECODER
+30dB
PROG LINK IN
MIC
CAT5 RUN 1
RS485
(priority)
REC
CAT5 RUN
VOICE
2-4
&
DATA
MICROPROCESSOR
LOGIC
ROUTING
DATA LINK
MASTER
0dB
SIGNAL
(internal)
CHIME
-27dB
CHIME ENABLE
-36dB
ALERT/EVAC
-6.5dB
GEN
TONE
OUTPUT
LEVEL
SUM INPUT
GEN
TONE/
CHIME
SLAVE
COM
EVAC
ALERT
DETECT
+13.5dB
-20dB
SUM INPUT
P1
PROGRAM
REPEATED
FOR
PROGRAMS 2 - 4
Australian Monitor
INSTALLATION SERIES
21
Page 22
11. DIMENSIONS
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 PAGE ENABLE
TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE
PROG1 PROG1 PROG1 PROG 1 PROG 1 PROG1 PROG 1 PROG1
BASS BASS BASS BASS BASS BASS BASS BASS
PROG2 PROG 2 PROG 2 PROG2 PROG 2 PROG2 PROG 2 PROG2
PROG3 PROG 3 PROG 3 PROG3 PROG 3 PROG3 PROG 3 PROG3
PROG PROG PROG PROG PROG PROG PROG PROG
MIC MIC MIC MIC MIC MIC MIC MIC
76.00 mm
PROG4 PROG 4 PROG 4 PROG4 PROG 4 PROG4 PROG 4 PROG4
55555555
44444444
66666666
33333333
77777777
22222222
88888888
11111111
99999999
00000000
10 10 10 10 10 10 10 10
MASTER1 MASTER2
MASTER3
MASTER4 MASTER 5 MASTER 6 MASTER 7 MASTER 8
482.00 mm
466.00 mm
444.00 mm
ZONE5
ZONE1
ZONE6
ZONE2
ZONE7
ZONE3
ZONE8
ZONE4
Australian Monitor
INSTALLATION SERIES
ON
POWER
88.00 mm
MASTER
SLAVE
ENGINEERED BYAUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIA
POWER IN
VDC
+24V
18.00 mm
PROG 1PROG 3 PROG2PROG 4
PROG LINKS
INPUTOUTPUT
CAT5CAT5CAT5CAT5 RUN 1RUN 2RUN 3RUN4DATALINK
DC
IN
SUMTONEGEN
INPUTOUTPUT
SUM
GROUND
EVAC
ALERT
COMMON
GROUND
+24V
LEVELLEVEL
7
ZONE OUTPUTS
5
6
PROGPROG PROGPROG GAINGAIN
MICMIC MICMIC
3
4
GAINGAIN
LINELINE LINELINE
21
187.50 mm
6.00 mm
Australian Monitor
INSTALLATION SERIES
22
Page 23
12 .SPECIFICATIONS
-Dimensions:
-Weight:
-Power Input:
-
Program Sources:
(trim max)
-Sum Input:
-Frequency Response: (0dB/-3dB)
88.0 x 482.0 x 205.5 (HxWxD) mm
Net 4.5kg Shipping 5.5kg Net 9.9lb Shipping 12.1lb
20VAC 30VA max
Unbalanced (RCA)
Input Impedance:100kohm Sensitivity: 150mV (-14dBu)
Balanced (XLR)
Input Impedance: 1k3ohm Sensitivity: 1mV (-57dBu)
Min Trim: -46dB
Input Sensitivity: 160mV (-13.5dBu) Threshold: -46dBu (at output, ind of input)
15Hz - 17kHz
-THD:
-Noise:
-Output:
All measurements are reference to 1.5V (+6dBu)
0.005%
Page Mic: -84dB Other Inputs: -89dB
1.5Vrms 600ohm Max: 9Vrms
23
Australian Monitor
INSTALLATION SERIES
Page 24
AUSTRALIA and NEW ZEALAND
www.australianmonitor.com.au
Sydney (NSW & ACT Sales)
Private Bag 149, Silverwater NSW 1811 149 Beaconsfield Street, Silverwater NSW 2128 Ph: (02) 9647 1411 Fax: (02) 9648 3698 E-mail: nsw@audiotelex.com.au
Melbourne (Vic & Tas Sales)
P.O. Box 151, Blackburn South VIC 3130 22/277 Middleborough Road, Box Hill VIC 3128 Ph: (03) 9890 7477 Fax: (03) 9890 7977 E-mail: vic@audiotelex.com.au
Brisbane (Qld Sales)
P.O. Box 871, Fortitude Valley QLD 4006 42 Commerical Road, Fortitude Valley QLD 4006 Ph: (07) 3852 1312 Fax: (07) 3252 1237 E-mail: qld@audiotelex.com.au
Adelaide (SA & NT Sales)
P.O. Box 157, Hindmarsh SA 5001 31 Walsh Street, Thebarton SA 5031 Ph: (08) 8352 4444 Fax: (08) 8352 4488 E-mail: sa@audiotelex.com.au
EUROPE/ASIA/MIDDLE EAST
www.australianmonitor.com.au
International Sales
Private Bag 149, Silverwater NSW 1811 149 Beaconsfield Street, Silverwater NSW 2128 Australia Ph: 61-2- 9647 1411 Fax: 61-2-9748 2537 E-mail: international@audiotelex.com.au
Perth (WA Sales)
P.O. Box 404, North Perth WA 6906 299 Fitzgerald Street, West Perth WA 6005 Ph: (08) 9228 4222 Fax: (08) 9228 4233 E-mail: wa@audiotelex.com.au
Auckland (NZ Sales)
P.O. Box 512, Albany 1331 Unit B, 11 Piermark Drive, Albany 1331 Ph: (09) 415 9426 Fax: (09) 415 9894 E-mail: audiotlx@nznet.gen.nz
USA/MEXICO/SOUTH AMERICA
www.australianmonitor.com
Sennheiser Electronic Corporation
1 Enterprise Dr, Old Lyme, CT 06371 Ph: (860) 434 9190 Fax: (860) 434 1759
ENGINEERED BY AUDIO TELEX COMMUNICATIONSPTY LTD SYDNEY AUSTRALIA
POWER IN
MASTER
SLAVE
VDC
+24V
CAT 5CAT 5CAT 5CAT 5 RUN 1RUN 2RUN 3RUN 4DATALINK
+ 24V DC
GROUND
COMMON
ALERT
EVAC
GROUND
SUM IN
PROG LINKS
SUMTONE GEN
INPUTOUTPUT
LEVELLEVEL
INPUTOUTPUT
8
7
6
ZONE OUTPUTS
5
PROG 1PROG 3 PROG 2PROG 4
PROGPROG PROGPROG
GAINGAIN
MICMIC MICMIC
4
3
GAINGAIN
LINELINE LINELINE
21
Loading...