Australian Monitor DigiPage User Manual

Australian Monitor
INSTALLATION SERIES
Clever Features, Contractor Friendly
DigiPageJr
Multizone Paging
&
Program Selection
System
&
Operation
Manual
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 PAGE ENABLE
TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE
PROG1 PROG1 PROG1 PROG 1 PROG 1 PROG1 PROG 1 PROG1
BASS BASS BASS BASS BASS BASS BASS BASS
PROG2 PROG 2 PROG 2 PROG2 PROG 2 PROG2 PROG 2 PROG2
PROG3 PROG 3 PROG 3 PROG3 PROG 3 PROG3 PROG 3 PROG3
PROG PROG PROG PROG PROG PROG PROG PROG
MIC MIC MIC MIC MIC MIC MIC MIC
PROG4 PROG 4 PROG 4 PROG4 PROG 4 PROG4 PROG 4 PROG4
55555555
44444444
66666666
33333333
77777777
22222222
88888888
11111111
99999999
00000000
10 10 10 10 10 10 10 10
MASTER 1 MASTER 2
MASTER 3
MASTER 4 MASTER 5 MASTER 6 MASTER 7 MASTER 8
ZONE1
ZONE2
ZONE3
ZONE4
ZONE5
ZONE6
ZONE7
ZONE8
Australian Monitor
INSTALLATION SERIES
ON
POWER
AUS, EUR, USA Copyright 20th Nov 2003 Rev A: 20th Nov 2003 Rev B: 11th Aug 2004 Rev C: 14th Nov 2006
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Internal Revision Info Rev 1 25/06/03 Rev 2 09/10/03 Rev 3 05/11/03 Rev 4 06/11/03 Rev 5 20/11/03
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operation and main­tenance (servicing) instructions in the literature accompanying the appliance.
WARNING !
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
Australian Monitor
INSTALLATION SERIES
2
Caution:
To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade ex­posure.
To prevent electric shock, match wide blade of plug to wide slot, fully insert.
CONTENTS
Page
1. Introduction 4
2. Front Panel 5
3. Back Panel 8
4. Installation 11
5. Setup 14
6. Linking Two DigiPageJr Systems 16
7. Paging Station 18
8. Accessories 20
9. Troubleshooting Guide 20
10. Block Diagram 21
11. Dimensions 22
12. Specifications 23
3
Australian Monitor
INSTALLATION SERIES
1. INTRODUCTION
The Australian Monitor Installation Series DigiPageJr is a two rack unit multizone paging and source selection system that offers unprecedented flexibility for multizone paging & source routing applications. Four program inputs are available to each of eight zone outputs. The DigiPageJr is also expandable to 16 zones via a simple link cable to a second unit. Paging stations are available in 8 zone and 16 Zone models allowing paging into any individual zone, any combination of zones or All Call. There is also the ability to have one Paging Station as a priority paging station. The Paging stations connect via an inexpensive and industry standard CAT5 cable network. An overall priority input is also provided for emergency or evacuation signals. The DigiPageJr is powered by an (included) external plug-pack power supply or via 24VDC. The DigiPageJr is a versatile and well featured product that provides a simple solution to the complex applications of multizone paging and source routing.
We thank you for choosing Australian Monitor Installation Series and as with all our products, the DigiPageJr offers clever features and is contractor friendly.
Australian Monitor
INSTALLATION SERIES
4
2. FRONT PANEL
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE
PROG1 PROG 1 PROG 1 PROG1 PROG 1 PROG1 PROG 1 PROG1
BASS BASS BASS BASS BASS BASS BASS BASS
PROG2 PROG 2 PROG 2 PROG2 PROG 2 PROG2 PROG 2 PROG2
PROG3 PROG 3 PROG 3 PROG3 PROG 3 PROG3 PROG 3 PROG3
PROG PROG PROG PROG PROG PROG PROG PROG
MIC MIC MIC MIC MIC MIC MIC MIC
PROG4 PROG 4 PROG 4 PROG4 PROG 4 PROG4 PROG 4 PROG4
55555555
44444444
66666666
33333333
77777777
22222222
88888888
11111111
99999999
00000000
10 10 10 10 10 10 10 10
MASTER 1 MASTER 2
MASTER 3
MASTER 4 MASTER 5 MASTER 6 MASTER 7 MASTER 8
Expanded view
PAGE ENABLE
ZONE5
ZONE1
ZONE6
ZONE2
ZONE7
ZONE3
ZONE8
ZONE4
Australian Monitor
INSTALLATION SERIES
7 9
8
3
ON
POWER
1
2
4
5
6
5
Australian Monitor
INSTALLATION SERIES
The controls detailed below (1-6) apply to each output zone, as indicated by ZONE 1 .. ZONE 8 on the front panel.
1 PROG 1-4:
This series of program switches (PROG 1- PROG 4) allows any one of the connected program sources to be switched to this zone. Note that these are mechanically interlocking switches: only one program may be selected at a time. Program inputs may be mic or line, see Back Panel on page 8.
2 MASTER 1-8:
This control adjusts the overall output level of the zone.
3 TREBLE
The treble control has 10dB of cut or boost at 10kHz. The treble control affects the entire zone.
NOTE: Note that ‘center ’ is to the right (3 o’clock), not the top (12 o’clock).
4BASS
The bass control has 12dB of cut or boost at 100Hz. The bass control affects the entire zone.
NOTE: Note that ‘center ’ is to the right (3 o’clock), not the top (12 o’clock).
5 PROG
This control adjusts the overall level of the selected program source into the zone.
NOTE: To balance the differing levels of each program input, the program trim
controls on the Back Panel should be used (see Back Panel and Setup sections)
6PAGE
This control adjusts the paging mic level into the zone.
Australian Monitor
INSTALLATION SERIES
6
Located at the right-hand end of the unit, these controls affect all zones.
7 PAGE ENABLE
This switch allows the zone to be included in or isolated from the paging function. You may want to do this when a zone is an area such as a function room that occasionally may need to be isolated from paging.
8ON
This LED indicates there is power to the unit.
NOTE: When 24VDC emergency power is supplied this LED will always be on.
9 POWER
This switches power from the power supply (included ).
NOTE: When 24VDC emergency power is supplied, the unit is on regardless of
the switch position.
7
Australian Monitor
INSTALLATION SERIES
3. BACK PANEL
MASTER
SLAVE
7
8
ENGINEERED BY AUDIO TELEX COMMUNICATIONSPTY LTD SYDNEY AUSTRALIA
POWER IN
VDC
+24V
6
4b
1
PROGPROG PROGPROG
GAINGAIN
ZONE OUTPUTS
6
5
MICMIC MICMIC
4
LINELINE LINELINE
3
21
23
CAT 5CAT 5CAT 5CAT 5 RUN 1RUN 2RUN 3RUN 4DATALINK
4a
5
PROG LINKS
INPUTOUTPUT
SUMTONE GEN
INPUTOUTPUT
SUM IN
EVAC
GROUND
ALERT
GROUND
COMMON
+ 24V DC
LEVELLEVEL
8
7
1 PROG 1 - 4 Input Section
LINE
The pair of RCA sockets accepts unbalanced line level inputs. Stereo signals are internally summed to mono.
PROG 1PROG 3 PROG 2PROG 4
GAINGAIN
MIC
The XLR socket accepts balanced microphone level signals.
PROG GAIN
PIN 2
HOT
+
PIN 3 COLD
PIN 1 GND
-
FEMALE XLR
The trimpot controls the input gain of BOTH the balanced and unbalanced program inputs. In a Master/Slave configuration, these also control program linked inputs. (see Linking Section)
2 ZONE OUTPUTS
There is a balanced XLR line level output for each zone.
PIN 1 GND
MALE XLR
NOTE: If connecting to an unbalanced input, the negative pin (3) should not be
connected to ground but left floating.
NOTE: When operating as a slave unit, outputs labelled 1 to 8 will correspond to
zones 9 to 16, respectively. (see Linking Section)
PIN 2
HOT
+
PIN 3 COLD
-
Australian Monitor
INSTALLATION SERIES
8