AUSTRALIAN MONITOR AV2.2P Operation Manual

PROFESSIONAL AUDIO AMPLIFIER
AV2.2P AV2.4P
OPERATION MANUAL
AV2.2P AV2.4P
IMPORTANT SAFETY INFORMATION
arrived in good condition. Should you ever need to ship the unit, use
only the original factory packing.
2. Read all documentation before operating your equipment. Retain
all documentation for future reference.
3. Follow all instructions printed on unit chassis for proper operation.
4. Do not spill water or other liquids into or on the unit, or operate
the unit while standing in liquid.
5. Make sure power outlets conform to the power requirements listed
on the back of the unit.
6. Do not use the unit if the electrical power cord is frayed or broken.
The power supply cords should be routed so that they are not likely
to be walked on or pinched by items placed upon or against them,
paying particular attention to cords and plugs, convenience
receptacles, and the point where they exit from the appliance.
7. Always operate the unit with the AC ground wire connected to the
electrical system ground. Precautions should be taken so that the
means of grounding of a piece of equipment is not defeated.
8. Mains voltage must be correct and the same as that printed on the
rear of the unit. Damage caused by connection to improper AC voltage
is not covered by any warranty.
9. Have gain controls on amplifiers turned down during power-up
to prevent speaker damage if there are high signal levels at the inputs.
10 Power down & disconnect units from mains voltage before making
connections.
11. Never hold a power switch in the “ON” position if it won’t stay
there itself!
12. Do not use the unit near stoves, heat registers, radiators, or other heat
producing devices.
13. Do not block fan intake or exhaust ports. Do not operate equipment
on a surface or in an environment which may impede the normal flow
of air around the unit, such as a bed, rug, weathersheet, carpet,
or completely enclosed rack. If the unit is used in an extremely dusty
or smoky environment, the unit should be periodically “blown free”
of foreign matter.
14. Do not remove the cover. Removing the cover will expose you
to potentially dangerous voltages. There are no user serviceable
parts inside.
15. Do not drive the inputs with a signal level greater than that required
to drive equipment to full output.
16. Do not connect the inputs / outputs of amplifiers or consoles to any
other voltage source, such as a battery, mains source, or power supply,
regardless of whether the amplifier or console is turned on or off.
17. Do not run the output of any amplifier channel back into another
channel’s input. Do not parallel- or series-connect an amplifier output
with any other amplifier output. Australian Monitor Inc is not
responsible for damage to loudspeakers for any reason.
18. Do not ground any red (“hot”) terminal. Never connect a “hot” (red)
output to ground or to another “hot” (red) output!
19. Non-use periods. The power cord of equipment should be unplugged
from the outlet when left unused for a long period of time.
20. Service Information Equipment should be serviced by qualified service
personnel when:
A. The power supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the equipment
C. The equipment has been exposed to rain
D. The equipment does not appear to operate normally, or exhibits a
marked change in performance
E. The equipment has been dropped, or the enclosure damaged.
THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL
This operation manual contains important information regarding safety precautions, installation, performance, operation and maintenance of your AMAV power amplifier. You should familiarize yourself with the contents of this manual before operating your amplifier.
INTRODUCTION AND CONTENTS
PAGE 3
AV2.2P / AV2.4P – OPERATION MANUAL
Congratulations on choosing Australian Monitor for you professional amplification requirements.
The AMAV stereo power amplifiers are designed for the demanding commercial audio-visual Market. Two amplifier models are available within the AMAV range. The AV2.2P delivers 100 watts per channel at 4 ohms from an elegant, 1RU slim line package. The AV2.4P delivers 200 watts per channel at 4 ohms from an elegant, 2RU package. Both amplifiers feature front panel dual colour status LEDs, on board limiter, ground lift switch and the option of bridged operation.
Add to this the AV2.2P and AV2.4P’s whisper quiet operation, achieved via its convection cooled design and you have an elegant, high quality audio amplifier.
The AV2.2P and AV2.4P offers the power and the features demanded by any quality AV application.
INTRODUCTION 3
FEATURES 4
CONTROLS, CONNECTORS AND INDICATORS
FRONT PANEL 5
REAR PANEL 6
INSTALLATION 7
OPERATION 9
MAINTENANCE 10
BLOCK DIAGRAM 10
SPECIFICATIONS 11
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operational and maintenance (servicing) instructions in the literature accompanying the appliance.
To prevent electric shock do not use this (polarised) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure. To prevent electric shock, match wide blade of plug to wide slot, fully insert.
Caution:
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK),
NO USER SERVICEABLE PARTS INSIDE,
REFER SERVICING TO QUALIFIED SERVICE PERSONAL.
WARNING!
TO REDUCE THE RISK OF FIRE OR ELECTRIC HOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AUS, EUR, USA
Rev A: Mar 2007
FEATURES
PAGE 4
AV2.2P / AV2.4P – OPERATION MANUAL
> Custom designed, heavy duty steel chassis.
> Rear rack mount ears.
> Symmetrical layout - even weight distribution.
> High current power supply.
> High efficiency toroidal mains transformer.
> Silent convection cooling.
> Balanced inputs and buffered attenuators.
> Input signal strapping (loop through) connectors
> Signal ground lift switch.
> Stereo or bridged operation
> Binding post speaker output connection
> 1 Watt output indication (2.828 volts).
> Output clip indication.
> High-quality, close-tolerance components throughout.
> Suppression of inrush current at mains turn-on.
> Input muting at turn-on.
> Input overvoltage protection.
> Radio-frequency interference suppression.
> Short-circuit protection.
> High overload mains fuse.
> Internal, independent DC supply rail fuses.
> Layout, grounding, decoupling and componentry have been optimized to provide the user with stability, reliability and longevity.
PROTECTION FEATURES
Loading...
+ 8 hidden pages