Australian monitor AMIS604 User Manual

AMIS604
4 x 60 Watt Mixer Amplifier
Description
The AMIS604 features four individual 60 watt mixer amplifiers in a 2 RU chassis and is suitable
for rack or desk mounting. The amplifier may operate from mains power or 24V DC.
Inputs
Each of the four mixer amplifiers feature three dual mic/line inputs accessible via barrier strips
on the rear of the unit. Each input may be switched between mic or line via an internal dip
Outputs
The AMIS604 features 100 volt, 70 volt, 8 ohm isolated transformer outputs per amplifier
module. With the addition of an optional tone generator module a vox triggered relay output
is also available on the rear panel for activation of external devices from the vox muting circuit.
In most cases this would be used as a muting bypass relay, which when used with the appro-
priate external attenuator, such as our ATC5143FS, will maintain preset paging levels irre-
spective of the attenuator setting. VCA control of the master output of each amplifier module
is also available via the rear terminal strip. Each amplifier also includes a recessed bass and
treble control.
Tone Generator
The AMIS604 offers the convenience of an optional plug in tone generator module. All four
channels of this amplifier may have their own (ATC5489) tone generator module. The individ-
ual tones are accessible via contact closure on the rear of each amplifier module. There are
four tones on the optional plug in module, alert, evac, bell and pre announce. Spare contacts
on the board allow a vox triggered output for the activation of remote devices.
Muting
VOX muting is standard on the AMIS604. A mic or line signal on channel 1 will mute channels
2 and 3 per amplifier. The muting function can be disabled via an internal link. Each of the four
mixer amplifier modules has its own muting circuit.
Phantom Power
Phantom Power (18 volts DC) is available from all mic inputs. An internal dip switch allows
phantom power to be selected on a per input, per module basis.
Protection
Internal current limiting protects the amplifier from both overload and overdrive conditions.
Fan cooling will be activated if the unit exceeds a factory preset temperature.
Australian Monitor Installation Series amplifiers feature a protection network that provides
greater stability and performance. Our amplifiers are recognised
worldwide for their reliability and this is due to the extensive levels of
current limiting which protect the amplifiers from both overload and
overdrive conditions.
Power Output 4 x 60 Watts RMS
Maximum Load Per Amplifier 160 Ohms @ 100 Volts
Power Bandwidth 60Hz - 15kHz < 0.5% THD
Frequency Response 60Hz - 15kHz (± 3dB)
Total Harmonic Distortion 0.5% @ 1kHz rated power
Signal To Noise Ratio -74dB with all controls at their centre position
Tone Controls Bass @ 100Hz: Boost +12dB Cut -12dB; Treble @ 10kHz: Boost +9dB Cut -9dB
Inputs Three mic/aux universal inputs per mixer amplifier module.
Mic/Line selection can be made via an internal dip switch
Input Sensitivity Mics: 1mV @ 200 Ohms; Aux 75mV @ 47K Ohms
Outputs Speaker: 100, 70 Volts, 8 Ohms
VCA Master Level Control Via a 500/1K pot added to the rear barrier strip of each amplfier module
Phantom Power Selectable per input of each amplifier module via an internal dip switch. 18 V
Controls 3 Input channel gain controls, 1 Bass control, 1 Treble control,
1 Master VCA gain control per amplifier
Indicators Power “on” LED
Power Source AC 230/240V - 50Hz; DC 24V; 110V - 60Hz (special) 3 pin IEC connector
Power Consumption 400 Watts
Protection Overload and overdrive protection, plus AC and DC fuses
Dimensions/Weight 88mm H x 480mm W x 350mm D (Chassis Dimensions only). 17kg
Rack Mounting Standard
Tone Generators Optional four tone generator module (ATC5489). Includes Bell, Pre-Announce,
Alert and Evac Tones, plus a vox triggered relay output.
Muting Built-in VOX muting. Channel 1 will mute channels 2 and 3 per amplifier
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The four channel mixer amplifier shall have three universal input channels, accessible via a rear panel
barrier strip on each of the four amplifier modules. Each amplifier module shall allow remote VCA con-
trol of the master output. Phantom power selection on a per channel, per amplifier basis shall also be
included. A Vox triggered output shall also be available on an optional four tone generator card.
Each amplifier master section shall include one master VCA accessible gain control, two EQ controls,
one with 12dB of cut and boost at 100Hz and the other with 9dB of cut and boost at 10kHz. Speaker
outputs shall be transformer isolated at 100 volt, 70 volt & 8 ohms. The amplifiers must be capable of
delivering 60 watts RMS into a 160 ohm inductive load, with less than 0.5% distortion measured at
1 kHz and with system hum and noise of -74dB or better.
The amplifier shall be an Australian Monitor Installation Series model AMIS604.
Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (ABN 78 001 345 482), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698 VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977 QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237 WA Tel: (08) 9228 4222 Fax: (08) 9228 4233
SA Tel: (08) 8352 4444 Fax: (08) 8352 4488 NZ Tel: (09) 415 9426 Fax: (09) 415 9864 Export Enquiries: export@audiotelex.com.au
Website: www.australianmonitor.com.au
Loading...