IM PO RTAN T SA FE TY I NF ORM AT IO N
1. Save the carton and packing material even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing.
2. Read all documentation before operating your equipment. Retain all documentation for future reference.
3. Follow all instructions printed on unit chassis for proper operation.
4. Do not spill water or other liquids into or on the unit, or operate the unit while standing in liquid.
5. Make sure power outlets conform to the power requirements listed on the back of the unit.
6. Do not use the unit if the electrical power cord is frayed or broken. The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance.
7. Always operate the unit with the AC ground wire connected to the electrical system ground. Precautions should be taken so that the means of grounding of a piece of equipment is not defeated.
8. Mains voltage must be correct and the same as that printed on the rear of the unit. Damage caused by connection to improper AC voltage is not covered by any warranty.
9. Have gain controls on amplifiers turned down during power-up to prevent speaker damage if there are high signal levels at the inputs.
10 Power down & disconnect units from mains voltage before making connections.
11. Never hold a power switch in the “ON” position if it won’t stay there itself!
12. Do not use the unit near stoves, heat registers, radiators, or other heat producing devices.
13. Do not block fan intake or exhaust ports. Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit, such as a bed, rug, weathersheet, carpet, or completely enclosed rack. If the unit is used in an extremely dusty or smoky environment, the unit should be periodically “blown free” of foreign matter.
14. Do not remove the cover. Removing the cover will expose you to potentially dangerous voltages. There are no user serviceable parts inside.
15. Do not drive the inputs with a signal level greater than that required to drive equipment to full output.
16. Do not connect the inputs / outputs of amplifiers or consoles to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off.
17. Do not run the output of any amplifier channel back into another channel’s input. Do not parallel- or series-connect an amplifier output with any other amplifier output. Australian Monitor Inc is not responsible for damage to loudspeakers for any reason.
18. Do not ground any red (“hot”) terminal. Never connect a “hot” (red) output to ground or to another “hot” (red) output!
19. Non-use periods. The power cord of equipment should be unplugged from the outlet when left unused for a long period of time.
20. Service Information Equipment should be serviced by qualified service personnel when:
A. The power supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the equipment
C. The equipment has been exposed to rain
D. The equipment does not appear to operate normally, or exhibits a marked change in performance
E. The equipment has been dropped, or the enclosure damaged.
THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL
AMIS SERIES 60/120 manual.indd 2 2/7/07 12:42:31 PM
I N T R O D U C T I O N A N D C O N T E N T S
PAG E 3
A M I S S E R I E S I N S TA L L AT IO N & O PE R AT IO N M ANU A L
The AMIS60 and AMIS120 mixer amplifiers are designed for commercial installations. Both models operate on 230/240 VAC, 50Hz (115VAC, 60Hz) or 24 VDC, and may be desk or rack mounted (rack mount kit supplied fitted). The AMIS60 will deliver 60 watts into a load of 8 ohms, 70 volt or 100 volt line. The AMIS120 will deliver 120 watts into a load of 4 or 8 ohms, 70 volt or 100 volt line. Both Models feature 6 universal mic/line inputs. The AMIS60/120 also feature a dual RCA record output while a balanced XLR output is also provided to feed external booster power amplifiers. Other standard features include on-board bell, pre-announce, alert & evac tones, remote master VCA control & priority muting. As standard, both models are self standing and come with rubber feet.
INTRODUCT IO N 3
FRONT PA N E L 4
REAR PA N E L 5
INSTA L L AT IO N 6
SETUP & T RO UB L E SHOOTING 7
DIMENSION S 8
BLOCK DIA GR AM 9
SPECIFICATIONS 10
AUS, EUR, USA
Copyright 21st Mar 2007
Rev A: 21st Mar 2007
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operational and maintenance (servicing) instructions in the literature accompanying the appliance.
To prevent electric shock do not use this (polarised) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure. To prevent electric shock, match wide blade of plug to wide slot, fully insert.
Caution:
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK),
NO USER SERVICEABLE PARTS INSIDE,
REFER SERVICING TO QUALIFIED SERVICE PERSONAL.
WARNING!
TO REDUCE THE RISK OF FIRE OR ELECTRIC HOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AMIS SERIES 60/120 manual.indd 3 2/7/07 12:42:32 PM
F R O N T PA N E L
PAG E 4
A M I S S E R I E S I N S TA L L AT IO N & O PE R AT IO N M ANU A L
2 3 41 5 6
CH 1-6
These control the individual level for each channel input.
BASS
There is 12dB of cut and boost at 100Hz. This EQ is the shelving type.
TREBLE
There is 9dB of cut and boost at 10kHz. This EQ is the shelving type.
MASTER
This controls the overall output level.
ON
This LED indicates the unit is powered “on”.
NOTE: When using the “24VDC” in terminals, the amplifier is ‘on’ and the power LED will always be on regardless of the position of the power switch.
POWER
This switch switches power on or off from the mains. The up position is on.
NOTE: When using the “24VDC” in terminals, the amplifier is ‘on’ regardless of the switch position.
1
2
4
5
3
6
AMIS SERIES 60/120 manual.indd 4 2/7/07 12:42:32 PM