MAG 4MHCS
User manual
The technical features can be change without forecast. AUR°EL S.p.A doesn’t assume any responsibility for the demages due to the improper use.
AUR°EL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY Rev.A 09.02.2011
Tel.: +390546941124 – Fax: +390546941660 Page 2 of 6
http://www.aurel.it - email: lab-el@aurel.it Preliminary
HOW IT WORKS
Jumpers 1 and 2 (see JP1 and JP2 in picture one) allow to set several kind of works for test and alarm
phase
.
FUNCTION JP1 JP2
RADIO MODE CLOSE OPEN
CALIBRATION FOR MAGNETIC SENSOR CLOSE CLOSE
SUPERVISED OPEN CLOSE
NORMALY WORKING X X
RADIO MODE:
It’s a function used during learning procedure to get the radio code in the matched
receiver and to verify the quality of the radio connection.
CALIBRATION OF MAGNETIC SENSOR:
It’s a function used during learning procedure of the
sensor that helps the installer to place the permanent magnet near the magnetic contact.
It is triggered by the closure of JP1 and JP2, the LED switches on when the magnet closes the magnetic
contact and switches off when the contact opens. No radio transmission is activated.
After five minutes from the starting of the procedure, the sensor will come back to the normal function.
To start again the function, disconnect and fit again JP1 and JP2 contacts.
SUPERVISION FUNCTION:
It sends to the receiver side a signal to give a feedback of the status
battery and the status of the magnetic, tamper , tear contacts.
It’s activated from the closing of JP2 contact, it’s foreseen a transmission each 60 seconds independent from
the alarm signal.
MAIN WORKING:
Normally is activated after the fitting of the battery or when “RADIO MODE” AND
“CALIBRATION OF MAGNETIC SENSOR” functions are finished. The sensor sends the status code when there
is a variation of the operation, eg opening or closing of any contact (see "SPECIFICATIONS OF THE RADIO
CODE). The led switches on for 100 ms to show the transmission. The time transmission is about 0.6 sec.
Acoustic and luminous signal.
Within the MAG 4MHCS are present a buzzer and a red LED with the following functions:
BUZZER: Used to signal low battery and it’s activated when the battery voltage drops below 2.1 volts or at
the procedure for supervision (every 60 minutes).
LED is activated for each radio transmissions (alarm, supervisory radio test). If the case of low battery
(below 2.1 V), it blinks quickly for 2 seconds every 5 minutes. The calibration function of the magnetic
sensor remains on when the magnetic contact is closed.