11.4 National Test Lab Requirement..........................................................................................27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
2/27
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
G150XG03 V5
Record of Revision
Version and Date Page Old description New Description
0.0 2011/6/8 All First Edition
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
3/27
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
G150XG03 V5
1. Operating Precautions
1) Since front polarizer is easily damaged, please be cautious and not to scratch it.
2) Be sure to turn off power supply when inserting or disconnecting from input connector.
3) Wipe off water drop immediately. Long contact with water may cause discoloration or
spots.
4) When the panel surface is soiled, wipe it with absorbent cotton or soft cloth.
5) Since the panel is made of glass, it may be broken or cracked if dropped or bumped on
hard surface.
6) Since CMOS LSI is used in this module, take care of static electricity and insure human
earth when handling.
7) Do not open nor modify the module assembly.
8) Do not press the reflector sheet at the back of the module to any direction.
9) In case if a module has to be put back into the packing container slot after it was taken
out from the container, do not press the center of the LED Reflector edge. Instead,
press at the far ends of the LED Reflector edge softly. Otherwise the TFT Module may
be damaged.
10) At the insertion or removal of the Signal Interface Connector, be sure not to rotate nor tilt
the Interface Connector of the TFT Module.
11) TFT-LCD Module is not allowed to be twisted & bent even force is added on module in a very
short time. Please design your display product well to avoid external force applying to module
by end-user directly.
12) Small amount of materials without flammability grade are used in the TFT-LCD module. The
TFT-LCD module should be supplied by power complied with requirements of Limited Power
Source (IEC60950 or UL1950), or be applied exemption.
13) Severe temperature condition may result in different luminance, response time.
14) Continuous operating TFT-LCD Module under high temperature environment may accelerate
LED light bar exhaustion and reduce luminance dramatically.
15) The data on this specification sheet is applicable when TFT-LCD module is placed in
landscape position.
16) Continuous displaying fixed pattern may induce image sticking. It’s recommended to use
screen saver or moving content periodically if fixed pattern is displayed on the screen.
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
4/27
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
G150XG03 V5
2. General Description
G150XG03 V5 is a Color Active Matrix Liquid Crystal Display composed of a TFT-LCD display, a
driver circuit, and a backlight system. The screen format is intended to support XGA (1024(H) x
768(V)) screen and 16.2M (RGB 8-bits) or 262k colors (RGB 6-bits). All input signals are LVDS
interface compatible. All design rules of this module can correspond to PSWG standard.
G150XG03 V5 is designed for industrial display applications.
2.1 Display Characteristics
The following items are characteristics summary on the table under 25
Items Unit Specifications
Screen Diagonal [inch] 15
Active Area [mm] 304.128(H) x 228.096(V)
condition:
Pixels H x V 1024x2, 768x2 (RGBW)
Pixel Pitch [mm] 0.297 x 0.297
Pixel Arrangement R.G.B.W. Rectangle
Display Mode TN, Normally White
Nominal Input Voltage VDD [Volt] 3.3 typ.
Typical Power Consumption [Watt] TBD
Weight [Grams] 1000g (max.)
Physical Size [mm] 326.5(H)x 253.5(V) x 13.1(D) (max.)
Electrical Interface 1 channel LVDS
Surface Treatment Anti-glare, Hardness 3H
Support Color 16.2M / 262K colors
Temperature Range
Operating
Storage (Non-Operating)
o
C]
[
o
C]
[
-30 to +85
-30 to +85
RoHS Compliance RoHS Compliance
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
5/27
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
G150XG03 V5
2.2 Optical Characteristics
The optical characteristics are measured under stable conditions at 25 (Room Temperature):
Item Unit Conditions Min. Typ. Max. Note
White Luminance
Uniformity
Contrast Ratio
Cross talk
Response Time
Viewing Angle
Color / Chromaticity
Coordinates
(CIE 1931)
Color Gamut %
[cd/m2] 100% Dimming
(center point)
%
%
[msec]
[msec]
[msec]
[degree]
[degree]
[degree]
[degree]
9 Points
400 700 - 4
- TBD TBD 5
Rising
Falling
Raising + Falling
Horizontal (Right)
CR = 10 (Left)
Vertical (Upper)
CR = 10 (Lower)
Red x
Red y
Green x
Green y
Blue x
Blue y
White x
White y
200 250 - 1
75 80 - 1, 2, 3
-
- 2.3 -
- - 16
70
70
50
70
TBD TBD TBD
TBD TBD TBD
TBD TBD TBD
TBD TBD TBD
TBD TBD TBD
TBD TBD TBD
0.263 0.313 0.363
0.279 0.329 0.379
- 60 -
5.7 -
80
80
60
80
6
-
7
-
-
Note 1: Measurement method
Equipment Pattern Generator, Power Supply, Digital Voltmeter, Luminance meter (SR_3 or equivalent)
Aperture
Test Point Center
Environment < 1 lux
LCD Module
Measuring distance
Module Driving Equipment
SR_3 or
equivalent
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
6/27
www.panelook.com
Global LCD Panel Exchange Center
(CR)
g
g
A
A
www.panelook.com
G150XG03 V5
Note 2: Definition of 9 points position (Display active area : 304.128(H) x 228.096(V))
90 %
Note 3: The luminance uniformity of 9 points is defined by dividing the minimum luminance values by the maximum test
point luminance
Minimum Brightness of nine points
W9
=
Maximum Brightness of nine points
Note 4Κ Definition of contrast ratio (CR):
Ӭ
Contrast ratio
Note 5Κ Definition of cross talk (CT)
=
50 %
Bri
htness on the “White” state
Bri
htness on the “Black” state
10 %
10 %
50 %
90 %
CT = | YB – YA | / YA × 100 (%)
Where
YA = Luminance of measured location without gray level 0 pattern (cd/m2)
YB = Luminance of measured location with gray level 0 pattern (cd/m2)
1/2
184 gray level
B
1/6
1/6
1/2
1/2
2/3 1/3
’
1/6
B’
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
1/6
1/3
1/2
2/3
G150XG03 V5 rev 0.0
7/27
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
G150XG03 V5
Note 6: Definition of response time:
The output signals of photo detector are measured when the input signals are changed from “White” to “Black”
(falling time) and from “Black” to “White” (rising time), respectively. The response time interval is between 10% and
90% of amplitudes. Please refer to the figure as below.
Optical
Optical
response
response
Note 7: Definition of viewing angle
%
100
90
90
10
10
0
0
TfTr
WhiteBlackWhite
WhiteBlackWhite
Tr
vertical range (off-normal viewing angles). The 180° viewing angle range is broken down as below: 90° (θ) horizontal
left and right, and 90° (Φ) vertical high (up) and low (down). The measurement direction is typically perpendicular to the
display surface with the screen rotated to its center to develop the desired
measurement viewing angle.
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
8/27
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
G150XG03 V5
3. Functional Block Diagram
The following diagram shows the functional block of the 15 inch color TFT/LCD module:
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
G150XG03 V5 rev 0.0
9/27
www.panelook.com
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.