INSTALLATION GUIDE FOR:
Battery Back-Up
AA-9103N
SIREN MOUNTING:
1. Find a suitable spot to mount the siren in the engine
compartment (firewall, sidewall, etc.).
2. Using siren bracket as a template, drill (2) 1/8" diameter
holes in mounting surface.
Note: If mounting on the firewall, make certain there is no
interference on the other side of the firewall.
3. Secure bracket using screws provided with kit.
4. Secure siren to the bracket using bolts and lock washers
provided.
WARNING - Open end of siren must point downward to
prevent water collection in horn end of siren.
Printed in U. S. A. Form No. 128-4503
WIRING:
RED WIRE - Splice to +12 VDC battery source lead of existing
alarm.
BLACK WIRE - Splice to chassis ground lead of existing
alarm.
WHITE w/ BLACK STRIPE WIRE - Connect to the positive
siren output from the alarm module.
BACK-UP SIREN
NOTE: BEFORE MAKING
CONNECTION, MAKE
SURE KEY IS IN THE "OFF"
POSITION AS SHOWN.
OFF
ON
BLACKWIRE-SPLICE INTOCHASSIS GROUND LEAD OF
EXISTING ALARM.
WHITE w/BLACK STRIPE - CONNECT TO
THE POSITIVESIRENOUTPUTFROM THE
ALARM MODULE.
RED WIRE - SPLICE TO +12VDC BATTERY
SOURCE LEAD TO EXISTING ALARM.
NOTE : MAKE SPLICE CONNECTIONS AS CLOSE TO
EXISTING ALARM AS POSSIBLE.