Aube Technologies TH149 User Manual

Electronic Thermostat
for Heat Pump and HVAC Systems
Installation and User Guide
n
The TH149 thermostat is used for the following systems:
The thermostat incorporates the following functions:
Introduction
• Heat pump (1H1C and 2H1C)
• HVAC (1H1C)
• System mode selection: heat, cool, auxiliary heat and off
• Fan mode selection: automatic or on (continuous)
• Emergency heat and fault LEDs
• Temperature display in °C or °F
• Backlit display
• Programmable heating and cooling cycle lengths
• Keypad lock
TH149
n Loosen the locking screw (the screw cannot be com-
pletely removed).
o Detach the front module from the back plate by pulling
the bottom part.
1.
p If necessary, bore the mounting holes
and insert anchors.
q Pass the wires through the opening of
the back plate and fix the plate to the wall using the screws provided.
2.3 Connecting the Thermostat
The connection of the new thermostat should be similar to that of the old ther­mostat; however, it can vary depending on the installation.
Emergency heat
Setpoint indicator
Temperature display
Cooling is On
Heating is On
* Auxiliary heat is available only for 2H1C systems.
o
Note: The installation must be performed by a qualified electrician.
Installation
indicator
Temperature adjustment buttons
Fault indicator
Fan mode selector
Auxiliary heat is On *
System mode selector
2.1 Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT POWER TO THE HEATING SYSTEM.
n Remove the old thermostat to access the wires. o Identify and label each wire (with the corresponding letter on the old ther-
mostat terminals) and remove them from the terminals.
p If necessary, strip the end of each wire (maximum of 6 mm). q If necessary, wrap the wires around a pencil to pre-
vent them from falling into the wall cavity.
r If the opening in the wall is too big, insulate it using
a non-flammable material to avoid air draughts behind the thermostat.
2.2 Installing the Back Plate
Note: For a new installation, choose a location approximately 1.5 m (5 feet) above the floor and on an inside wall. Avoid draughty areas (top of staircase, air outlet, etc.) or dead air spots (behind doors). Do not install the thermostat on a wall concealing air ducts nor expose it to direct sunlight.
R; C Power; 24 VAC
W Heater. This connection is not required for HP-1H1C.
Y Compressor
GFan
Reversing valve (see section 2.4). This connection is not required
O/B
for HVAC-1H1C.
L Fault
2.
2.4 Jumper settings
The jumpers (JP1 and JP2), on the back of the front module, are used to con­figure the thermostat according to your system type:
Jumper Parameter Settings
JP1 System
Reversing
JP2
valve
• Heat pump (HP position - default)
• HVAC (CN position)
• Activated in cool mode (O position - default)
• Activated in heat mode (B position)
2.5 Completing the Installation
n Reinstall the front module onto the back plate and tighten the locking
screw.
o Place the system mode selector switch to OFF.
Note: Leave the switch to OFF until you have verified that the thermostat is
properly configured (see section 3).
p Apply power back to the system. q Ensure that the thermostat is configured according to your system type
(see section 3).
TH149 400-149-000-B 10/5/05 1/2
p
The configuration parameters appear in the order shown below.
Configuration Menu
PARAMETERS DEFAULT OPTIONS
Temperature display °C °C or °F
Heating cycles per hour
Cooling cycles per hour
System type 2H 2H (2H1C) or 1H (1H1C)
1H1C type
1
2
3
3
When either the heating or the cooling parameter is displayed, use the mode selector switch to toggle between the two parameters.
The corresponding cycle lengths are: 2 = 30 min., 3 = 20 min., 4 = 15 min., 5 = 12 min., 6 = 10 min.
This parameter appears only if you select 1H1C for the system type.
1
1
4
4
HP HP (Heat Pump) or Cn (HVAC)
2, 3, 4, 5 or 6
2, 3, 4, 5 or 6
2
2
n To access the configuration menu, press and hold both temperature
adjustment buttons for more than 3 seconds.
o To go to the next parameter, once in the menu, press both temperature
adjustment buttons for more than 2 seconds.
p To modify the displayed parameter, press one of the temperature adjust-
ment buttons.
q You will exit the configuration menu at the end of the menu.
Note: The settings are not erased during a power outage.
q
4.1 System Mode
Use the system mode selector switch to place the system in heat mode, cool mode, emergency heat (E.H.) mode, or off.
Note: Emergency heat mode is not available on 1H1C systems.
For these systems, placing the selector on E.H. is the same as placing it on Off.
Auxiliary Heat
Only 2H1C systems are equipped with auxiliary heat. The auxiliary heat is used in the following conditions:
• When the setpoint is not attained after a 15-minute delay following the
• When the thermostat is placed in emergency heating (E.H.). In this mode,
4.2 Fan Mode
Use the fan mode selector switch to place the fan in automatic mode (AUTO) or continuous mode (ON).
Note: This switch is not functional if the fan is not connected to
the thermostat.
4.3 Viewing and Setting the Temperature
The actual temperature is normally displayed. To view the setpoint, press once on one of the temperature adjustment buttons. The setpoint is displayed
for 5 seconds and is indicated by the icon display. To change the setpoint, press the appropriate temperature adjustment button during the setpoint dis­play.
4.4 Backlight
The display illuminates for 12 seconds when either of the temperature adjust­ment buttons is pressed.
Operation
compressor activation. After the delay, the auxiliary heating is used along with the compressor.
only the auxiliary heat is used.
AUTO The fan operates only when heating or cooling is activated.
ON The fan operates continuously.
3.
4.5 Setpoint Lock
A switch on the back of the front module can be used to lock the setpoint.
n Remove the front module from the
back plate to access the switch.
o Place the switch (S1) to the I posi-
tion.
p Reinstall the front module.
5.
r
Power supply: 24 VAC Maximum load: 1.5 A per output @ 24 VAC Setpoint range (heat): 5 to 28°C (41 to 82°F) Setpoint range (cool): 15 to 35°C (59 to 95°F) Setpoint increment: ± 0.5°C (1°F) Display range: -5 to 50°C (23 to 122°F) Display resolution: 0.5°C (1°F) Short-cycle protection: 2 minutes Storage temperature: -20 to 50°C (-2 to 122°F) Dimensions: 79 mm x 81 mm x 25 mm (3.1 in. x 3.2 in. x 1.0 in.)
s
Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3)
4.
years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from
(ii) contact Aube. Aube will make the determination whether the product should be
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary by province, state or region.
t
For any questions regarding product installation or operation, contact our technical support team at:
705, Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8 Canada Tel.: (450) 358-4600 Toll-free: 1-800-831-AUBE Fax: (450) 358-4650 Email: service@aubetech.com
Technical Specifications
6.
Warranty
which you purchased it, or
returned, or whether a replacement product can be sent to you.
7.
Technical Support
For more information on our products, visit us at
www.aubetech.com
TH149 400-149-000-B 10/5/05 2/2