Aube Technologies TH133-15S, TH131-15S User Manual

Page 1
WARNING
This thermostat provides fast-cycling control and MUST therefore be used ONLY with solid-state relays. The use of electromechani­cal relays will result in reduced life expectancy and possibility of overheating of these devices.
TH131-15S
TH131-15S & TH133-15S
o
Installation
Control Module
User Guide
Electronic Thermostat
2.
Pilot wire indicator (Europe only)
TH133-15S
Front View
NOTE: Even if the following illustrations show the TH131 model only, they can also apply to the TH133 model.
n
This user guide covers the following thermostat models:
The TH131-15S model is designed for residential applications, whereas the TH133 model is designed for public areas as its controls are hidden and thus protected against unauthorized access. Both models can be configured for the following applications:
Description
• TH131-15S A/F/AF
• TH133-15S A/F/AF
Type Application
A Controls the ambient (room) temperature F Controls the floor temperature
AF Controls the ambient temperature and limits the floor temperature
Heating indicator
On/Off switch
Temperature selection dial
Rear View
Power Base
NOTE: Keep the thermostat's air vents clean and free from obstruc­tions.
3.
p
Configuration
3.1 Application Types
Type Switch Position
AUP (A/AF)
AF UP (A/AF)
FDOWN (F)
Position the switch, on the back of the control module, according to your application.
1.
3.2 Minimum and Maximum Limits (TH131-15S only)
Use the two potentiometers on the back of the control module to set the minimum and maximum tem­perature limits. Depending on your application, the potentiometers limit the following temperature:
ambient temperature (A)floor temperature (F or AF)
Use a flat-tip screwdriver to rotate the potentiometers until the notch points to the desired temperature limit.
notches
TH131-15S & TH133-15S 400-131-022-A 1/11/06 1/2
Page 2
q
Operation
4.1 Temperature Adjustment
TH131-15S
Use the dial on the front of the thermostat to set the desired tempera­ture.
NOTE: If the dial is placed at a temperature beyond the high or low temperature limit, the temperature will be maintained at that limit (see section 3.2).
TH133-15S
Remove the control module from the base and use the dial on the back of the control module to set the desired temperature.
4.2 On/Off Switch (TH131-15S only)
Use the On/Off switch to turn the thermostat Off when it is not used (e.g., in the summer).
r
Setpoint range: 7°C, 15°C to 35°C (45°F, 59°F to 95°F)
Minimum temperature limit: 5°C to 25°C (41°F to 77°F) Maximum temperature limit: 15°C to 35°C (59°F to 95°F)
Accuracy: ± 0.2°C (0.36°F) Storage: -20°C to 50°C (-4°F to 120°F) Heating cycle length: 15 seconds Software: Class A Controller: Electronic Size (H/W/D):
TH131: 78.9 x 78.9 x 16.3 mm (3.1 x 3.1 x 0.64 in.)
TH133: 78.9 x 78.9 x 18 mm (3.1 x 3.1 x 0.71 in.)
Specifications
4.
;
AUBE TECHNOLOGIES INC. THREE (3) YEAR LIMITED WARRANTY
Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of pu rchase b y the con sumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option).
If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to
(ii) contact Aube. Aube will make the determination whether the
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or
5.
malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from region to region.
If you have any questions about the product installation or operation, or concerning the warranty, contact us at:
Warranty
the place from which you purchased it, or
product should be returned, or whether a replacement product can be sent to you.
Customer Assistance
6.
7.
705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8 Tel.: (450) 358-4600 Toll Free: 1-800-831-AUBE Fax: (450) 358-4650 Email: aube.service@honeywell.com
For more information on our products, go to
www.aubetech.com
TH131-15S & TH133-15S 400-131-022-A 1/11/06 2/2
10 rue Ampère 95500 Gonesse France Tel.: 33 (0) 1 34 07 99 00 Fax: 33 (0) 1 34 07 99 19 Email: advaube@comintes.com
Page 3
PB130-024T
Installation Instructions
24-V Low-Voltage Power Base
n
This document describes the connections when the PB130-024T power base is used on any TH13x-15S series thermostat. When used on a TH13x-15S thermostat, this low-voltage power base must be connected to the line-voltage load using a solid-state relay (SSR). The PB130-024T is compatible with most solid-state relays; however, the following Aube relays are optimized for use with this power base:
RT850 solid-state relay (SSR)
RT850T solid-state relay (SSR) with built-in 24-V transformer
o
Applications
Supplied Parts
n One (1) power base o Two (2) plastic anchors p Two (2) mounting screws
p
For a new installation, choose a location about 1.5 m (5 ft.)The thermostat must be installed on an inside wall facing theAvoid locations where there are air drafts (top of staircase, air
q
The installation must be carried out by an electrician and must comply to local electrical codes.
Installation Guidelines
above the floor. heating system (except for floor heating systems). outlet), dead air spots (behind a door), direct sunlight or
concealed chimney or stove pipes (except for floor heating systems).
Installation Procedure
n Turn off power to the heating system at the main electrical panel
to avoid electrical shock.
o Wire the base according to your application. See typical wiring
diagrams in sections 4.1 and 4.2.
1.
2.
4.1 Single SSR with Built-in Transformer
Electrical Panel
Blue
Red
Black
Heater
4.2 Multiple SSRs with External Transformer
Electrical Panel
3.
Black
Heater
Heater
4.
r
Maximum load: 0.5 A / 24 VAC Operating temperature: 0°C to 50°C (32°F to 122°F) Storage: -20°C to 50°C (-4°F to 122°F) Size (H•W•D): 75 x 75 x 13 mm (2.9 x 2.9 x 0.5 in) Wire gauge: 14 to 22 AWG
Technical Specifications
Red
Black
Red
External 24 V Transformer
5.
p For a floor heating system installation, con-
nect the floor sensor between the S and R ter­minals.
q Secure the base to the wall using the provided screws and wall
anchors.
r Configure the switches located on the control module (if any).
Refer to the user guide.
s Install the control module onto the base. t Apply power to the heating system. u Verify the installation by checking that the heating system can be
turned On or Off using the thermostat.
PB130-024T 400-130-011-A 1/11/06 1/1
Loading...