TH131 & TH133
User Guide
Electronic Thermostat
TH131
Pilot wire indicator
(Europe only)
TH133
Front View
NOTE: Even if the following illustrations show the TH131 model only,
they can also apply to the TH133 model.
n
This user guide covers the following thermostat models:
The TH131 model is designed for residen tial applications, whereas
the TH133 model is designed for public areas as its controls are hidden and thus protected against unauthorized access. Both models
can be configured for the following applications:
Description
• TH131 A/F/AF
• TH133 A/F/AF
Heating indicator
On/Off switch
Temperature
selection dial
Rear View
2.
o
NOTE: Keep the thermostat's air vents clean and free from obstructions.
p
Installation
Control Module
Power Base
3.
Configuration
3.1 Application Types
Type Switch Position
AUP (A/AF)
1.
Position the switch, on the back of the control module, according to
your application.
AF UP (A/AF)
FDOWN (F)
Type Application
A Controls the ambient (room) temperature
F Controls the floor temperature
AF Controls the ambient temperature and limits the floor temperature
TH131 & TH133 400-131-002-C 1/11/06 1/2
3.2 Minimum and Maximum Limits (TH131 only)
Use the two potentiometers on the
back of the control module to set
the minimum and maximum temperature limits. Depending on your
application, the potentiometers
limit the following temperature:
ambient temperature (A)
floor temperature (F or AF)
Use a flat-tip screwdriver to rotate
the potentiometers until the notch
points to the desired temperature
limit.
notches
q
Operation
4.1 Temperature Adjustment
TH131
Use the dial on the front of the thermostat to set the desired temperature.
NOTE: If the dial is placed at a temperature beyond the high or low
temperature limit, the temperature will be maintained at that limit (see
section 3.2).
TH133
Remove the control module from the base and use the dial on the
back of the control module to set the desired temperature.
4.2 On/Off Switch (TH131 only)
Use the On/Off switch to turn the thermostat Off when it is not used
(e.g., in the summer).
r
TH131 accepts the six following pilot wire orders when installed on a
230 V power base.
s
Setpoint range: 7°C, 15°C to 35°C (45°F, 59°F to 95°F)
Minimum temperature limit: 5°C to 25°C (41°F to 77°F)
Maximum temperature limit: 15°C to 35°C (59°F to 95°F)
Accuracy: ± 0.2°C (0.36°F)
Storage: -20°C to 50°C (-4°F to 120°F)
Heating cycle length: 15 minutes
Software: Class A
Controller: Electronic
Size (H/W/D):
• TH131: 78.9 x 78.9 x 16.3 mm (3.1 x 3.1 x 0.64 in.)
• TH133: 78.9 x 78.9 x 18 mm (3.1 x 3.1 x 0.71 in.)
Pilot Wire Orders (Europe only)
ORDER SIGNAL DESCRIPTION
Comfort No signal Maintain temperature at setpoint
Reduced setpoint
(3.5k setback)
frost protection Maintain temperature at 7°C
Off Stop heating
1k setback Maintain temperature at 1°C below setpoint
2k setback Maintain temperature at 2°C below setpoint
Maintain temperature at 3.5°C below
setpoint
Specifications
4.
;
AUBE TECHNOLOGIES INC. THREE (3) YEAR LIMITED WARRANTY
Aube warrants this product, excluding battery, to be free from defects
in the workmanship or materials, under normal use and service, for a
period of three (3) years from the date of pu rchase b y the con sumer.
If at any time during the warranty period the product is determined to
be defective or malfunctions, Aube shall repair or replace it (at Aube's
option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to
(ii) contact Aube. Aube will make the determination whether the
This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by Aube that the defect or
5.
6.
malfunction was caused by damage which occurred while the
product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE
OF THIS PRODUCT. Some regions do not allow the exclusion or
limitation of incidental or consequential damages, so this limitation
may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR
DURATION OF THIS WARRANTY. Some regions do not allow
limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from region to region.
If you have any questions about the product installation or operation,
or concerning the warranty, contact us at:
Warranty
the place from which you purchased it, or
product should be returned, or whether a replacement product
can be sent to you.
Customer Assistance
705 Montrichard
Saint-Jean-sur-Richelieu
Quebec, Canada J2X 5K8
Tel.: (450) 358-4600
Toll Free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: aube.service@honeywell.com
For more information on our products, go to
www.aubetech.com
10 rue Ampère
95500 Gonesse
France
Tel.: 33 (0) 1 34 07 99 00
Fax: 33 (0) 1 34 07 99 19
Email: advaube@comintes.com
7.
8.
TH131 & TH133 400-131-002-C 1/11/06 2/2