Aube Technologies TH132 A-F-AF User Manual

Thank you for choosing the Aube TH132, a programma-
Control Module
TH132 A/F/AF
Owner’s Guide
TH132 Description
Models Overview
Configure the Switches
Install the Control Module
Power base
Control module
Air vents
Air vents
First Power ON
Set the Time and Day
Adjust the Temperature Setpoints
Select the Operating Mode
ble thermostat that provides both energy savings and total comfort.
n DAY/HOUR/MIN—Set the day and clock settings. o PGM—Program the schedule (programs). p MODE—Select the operating mode.
RETURN—To exit a function.
q To configure temperature setpoints:
r Adjust the floor temperature limit (AF only). s —Increase and decrease temperature. t —Indicates the number of the current
program when Automatic mode is enabled.
u Current operating mode (auto / manual ). In
Auto mode, the program’s associated setpoint icon is also displayed ( ).
v Indicates the room OR floor temperature. w Heating indicators (see “Temperature Control”
below).
TH132-A
This model has been designed to control a room’s ambi­ent temperature.
The TH132-A has one temperature sensor located in the control module.
TH132-AF
This model is designed to use a floor sensor to control the room temperature.
The TH132-AF has two temperature sensors:
The first one, installed in the control module, controls the ambient temperature.
The second one, installed in the floor (and connected to the power base), limits the temperature of the floor (the default setting of this limit is 82°F).
TH132-F
This model is designed to control floor heating systems. The TH132-F has one temperature sensor installed in the
floor (sensor is connected to the power base).
The TH132 has two switches, located on the upper-left part on the rear of the control module, which are used to set the following options:
Early Start
When the Early Start function is enabled (disabled by default), the TH132 calculates the optimum system start time to obtain the desired temperature by the set time. To enable this function:
Position switch #1 down.
Note: When this function is enabled, the
system can be activated before the pro­gram’s start time.
Temperature Display
By default, the TH132 displays the temperature in °C. If you wish to change to °F:
Position switch #2 up.
Note: When you switch from °C to °F or vice
versa, the , and setpoints must be redefined.
Align the bracket tabs on the control module with the holes located on top of the power base.
This control module must be installed on a PB130 series power base.
Note: Keep the thermostat's air vents clean and free from
obstructions.
Note: The screw cannot be removed completely.
On the first installation, the screen displays: 0:00, MO, and temperature (room/floor).
For Floor Heating Installations:
One of the two following messages may be dis­played when a problem occurs:
LO: The floor temperature is below 32°F (0°C), or
the temperature sensor is defective, or not connected.
The heating indicator is displayed and the relay is closed (energized).
HI: The floor temperature is above
140°F (60°C), or the temperature sensor is defective.
n Set the time (HOUR - MIN). o Set the day (DAY).
If you remove the module from its base for more than 2 hours, the time and day will have to be reprogrammed.
Comfort and Economy Setpoints
These setpoints are associated with the schedule’s pro­grams (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy) and are preprogrammed as follows:
A & AF models— 68°F, 64°F
F model— 82°F, 68°F
To modify a setpoint:
n Set the temperature using and press and hold the
or button until it is displayed on the screen.
o Press MODE/RETURN to exit.
Vacation Setpoint
The vacation setpoint is associated to the Vacation oper­ating mode and is preprogrammed to 50°F. To modify this setpoint, repeat above steps.
Floor Temperature Setpoint (AF model only)
The floor temperature limit is preprogrammed to 82°F to avoid damage to your floor. To modify, press the adjustment button (below ) using a pointed object, set the desired temperature using and press MODE/RETURN to exit.
The TH132 offers three operating modes:
Automatic Executes the schedule.
n Press MODE to select . The current
program number is displayed. You can temporarily bypass the current
program by setting a specific temperature setpoint
or by selecting one of the pre-defined setpoint buttons ( ). The new setpoint will be maintained until the beginning of the next program.
Manual —Maintains a constant temperature.
n Press MODE to select . o Set temperature or select one of the pre-
defined setpoint buttons ( ).
Vacation —Maintains the Vacation setpoint
during a prolonged absence.
Press .
400-132-000-A
The schedule is used with the Automatic mode. The
Program Your Schedule
705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8
Tel.: (450) 358-4600 Toll Free: 1-800-831-AUBE Fax: (450) 358-4650 Email: service@aubetech.com
10 rue Ampère 95500 Gonesse France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19 advaube@comintes.com
For more information on our products, visit us at:
www.aubetech.com
As an ENERGY STAR® partner, Aube Technologies has
determined that this product meets the E
NERGY STAR
guidelines for energy efficiency.
schedule controls the heating system to automatically switch between the Comfort and Economy temperature setpoints at the times you have programmed.
The schedule consists of 4 programs per day defined as follows:
Programs Setpoint
Leave home
i. The programs’ start time can be different for each day of the week.
i
Time
Wake-up
Back home
Night
To enter the programs’ start time
To shorten programming, you simply have to enter the start time for each program.
n Press PGM. o Press DAY to select the day (hold for 3 seconds to
select all days of the week).
Note: It is sometimes faster to program the same sched-
ule for the entire week and then to modify the exception days.
p Press PGM to select the program number (e.g. 1). q Press HOUR and MIN to set the start time. r Repeat steps 3 to 4 for remaining programs (e.g. 2, 3
and 4).
s Press MODE/RETURN to exit.
Note: After 60 seconds of inactivity, the thermostat will
automatically exit programming mode.
To clear a program time:
When you clear a program time entry, the TH132 will maintain the temperature setpoint of the last executed program until the beginning of the next program.
n Repeat steps 1 to 3 above. o Press CLEAR to erase the time entry. The time por-
tion of the LCD indicates --:-- when the program is inactive.
p Press MODE/RETURN to exit.
Programming Example
Programs MO TU WE TH FR SA SU
6:00 6:00 6:00 6:00 6:00 6:00 6:00
8:30 8:30 8:30 8:30 8:30 --:-- --:--
16:00 16:00 16:00 16:00 16:00 --:-- --:--
23:00 23:00 23:00 23:00 23:00 23:00 23:00
Comfort :
• Monday to Friday, between 6:00 and 8:30 and between 16:00 and 23:00.
• Saturday and Sunday, between 6:00 and 23:00.
Economy :
• Monday to Friday, between 8:30 and 16:00 and between 23:00 and 6:00.
• Saturday and Sunday, between 23:00 and 6:00.
To program this schedule
n Press PGM. o Press and hold DAY for 3 seconds to select all days
of the week.
p Press PGM to select program 1.
Set the time (6:00) using the HOUR and MIN buttons.
q Press PGM to select program 2.
Set the time (8:30) using the HOUR and MIN buttons.
r Repeat step 4 for remaining programs:
program 3 (16:00) and program 4 (23:00).
s When all programs are configured, press MODE/
RETURN to exit.
To erase programs 2 and 3 for Saturday and Sunday
n Press PGM. o Press PGM to select program 2. p Press DAY to select SAturday (SA). q Press CLEAR to erase the time (--:--). r Press DAY to select SUnday (SU). s Press CLEAR to erase the time (--:--). t Press PGM to select program 3. u Repeat steps 3 to 6. v Press MODE/RETURN to exit.
Temperature Control
The TH132 thermostat works differently than conventional electromechanical thermostats.
It is equipped with a proportional integral adaptive (PIA) controller which determines heating cycles by analyzing the temperature behavior history within the room.
The PIA controller reduces temperature swings providing accurate temperature control while increasing user com­fort.
The controller determines the amount of power required by the heating system to maintain the setpoint tempera­ture.
When the heating system is activated, one of the following icons is displayed:
1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100%
Technical Specifications
Model: TH132 A / AF / F
Display range: 32°F to 140°F (0°C to 60°C)
Setting range (ambient): 40°F to 86°F (5°C to 30°C)
Setting range
Pre-programmed temperature setpoints:
Comfort: A/AF: 68°F (20°C) and F: 82°F (28°C)
Economy: A/AF: 64°F (18°C) and F: 68°F (20°C)
Vacation: A/F/AF: 50°F (10°C)
Floor limit: AF: 82°F (28°C)
Temperature resolution display scale:0.1°
Storage:-4°F to 120°F (-20°C to 50°C)
Software: Class A
Controller: Electronic
Temperature control: Proportional integral adaptive,
15-minute heating cycles
Programming protection: Protected memory
Clock protection: 2 hours
Size (H/W/D): 3.3 x 3.1 x 0.5 in (83 x 79 x 13 mm)
(floor): 40°F to 104°F (5°C to 40°C)
Warranty
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two-year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the nearest shipping address.
If you have any questions concerning the programming of the TH132 programmable thermostat, call our technical support team at:
26/08/2003 400-132-000-A
Loading...