Thank you for choosin g an Aube product. The TH131 and TH133 non programmable thermostats
are equipped with a microprocessor and proportional integral adaptive (PIA) temperature control technology.
They can be installed on a 230 V power base (European model) or a 24 V low voltage base and combined with an electromechanical or TRIAC relay.
7HPSHUDWXUH&RQWURO$DQG $)RQO\
Position the switch according to your application:
+HDWLQJ &\FOHV
Ͽ
230 V LINE VOLTAGE BASE
ALWAYS 15 minutes
Ͽ
24 V LOW VOLTAGE BASE
•15 MIN Use with a TRIAC or electromechanical relay. Recommended for mechanical actuated system (water heating using a solenoid valve, etc.) or a fan-forced heater.
• 15 SEC Use only for installations with a solid state relay (SSR). Recommended for electric heating (baseboards, convectors, etc.).
212))6ZLWFK 7+ RQO\
The thermostat also features an On/Off switch making it possible to turn off the thermostat when it is not required (e.g. summer).
Use this feature to establish a temperature range by setting minimum and maximu m setpoints. Depending on the model, you can establish the temperature range for:
Ͽ
the ambient air (A)
Ͽ
the floor (AF and F)
Use a flat tip screwdriver to rotate the potentiometers until the notch points to the desired temperature.
([DPSOH
When the temperature is set outside the temperature range, it will revert to the nearest setpoint.
Example: MIN is 59°F and MAX is 77°F.
Ͽ
Using the front dial, you set the temperature at 50°F, the TH131 will revert to the minimum set value 59°F.
Ͽ
Using the front dial, you set the temperature at 86°F, the TH131 will revert to the maximum set value 77°F.
TH1 31 & TH1 33 A/AF/F
User Guide
Control Module
TH133
Heating command Indicator
Temperature selection dial
ON/OFF switch
TH131
Pilot wire indicator (European model only 230 V
Model Switch Temperature Control
A UP (A/AF)
AMBIENT
(no floor sensor)
AF UP (A/AF)
AMBIENT WITH FLOOR LIMIT
(requires a floor sensor)
F DOWN (F)
FLOOR
(requires a floor sensor)
(ambient sensor is deactivated)
Configure the Switches
Min/Max Temperature (TH1 31 only)
Align the bracket tabs on the control module with the holes located on the power base and secure using the screw.
NOTE: Keep the thermostat's air vents clean and free
from obstructions.
NOTE: The screw cannot be removed completely.
EUROPEAN MODEL ONLY (230 V BASE)
The TH131 accepts the six pilot wire commands:
Models: TH131 and TH133 A / AF / F
Setting Range : 45°F, 59°F to 95°F (7°C, 15°C to 35°C)
MIN: above-freezing temperature 45°F (7°C)
MAX: maximum temperature 95°F (35°C)
Potentiometers:
MIN: 41°F to 77°F (5°C to 25°C) MAX: 59°F to 95°F (15°C to 35°C)
Storage: -4°F to 120°F (-20°C to 50°C)
Software: Class A
Controller: Electronic
Temperature Control: Proportional integral adaptive,
15-minute or 15-second heating cycles
Accuracy: ± 0.36°F (0.2°C)
Size (H/W/D):
TH131: 3.1 x 3.1 x 0.64 in (78.9 x 78.9 x 16.3 mm)
TH133: 3.1 x 3.1 x 0.71 in (78.9 x 78.9 x 18 mm)
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed ag ainst workmanship defects for a two-year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has bee n used under normal conditions.
The warranty does not cover delivery costs and does not ap ply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other compa ny commitment.
AUBE Technologies Inc. cannot be he ld liable for related or rando m damages following the installation of this product. The defective product as well as the purchase invoice must be return ed to the place of purchase or mailed, prepaid and insured, to t he nearest address.
If you have any questions concerning the TH131 or TH133 the rmostat, call our technical support team at:
Install the Control Module
Control Module
Power Base
MODE
1
1. 1) Comfort 2) Reduced setpoint 3) Ab ove freezing (min)
4) Stop heating 5) 1°C setback 6) 2°C setback
SIGNAL COMMAND
1 No signal
Heating as per
defined setpoint
2
Current setpoint
minus 3,5°C
3 Setpoint at 7°C
4 Stop heating
5
Current setpoint
minus 1°C
6
Current setpoint
minus 2°C
Pilot Wire Commands
T
echnical Specifications
W
arranty and Service
705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8 Tel.: (450) 358-4600 Toll Free: 1-800-831-AUBE Fax: (450) 358-4650 service@aubetech.com
10 rue Ampère 95500 Gonesse France 33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19 advaube@comintes.com
13/01/2004 400-131-002-B
Included Parts
n One (1) PB130-230 power base
o One (1) floor sensor (for AF and F control modules only)
p One (1) wall plate (optional, in certain countries)
PB1 30A-230
Installation Instructions
230 V Lin e Voltage Power B ase
Technical Specifications
Model: PB130A-230 Supply: 230 VAC, 50 Hz Load: 15 A maximum (resistive only) Power: 3450 Watts (NI) @ 230 VAC Conformity: EN60730-2-9 / EN50081-1 / EN50082-2 Storage: -20°C to 50°C Protection:Class 2 Protection degree:IP20 Automatic action:Type 1.B Environment: Normally polluted Size (H•W•D): 2.95 x 2.95 x 0.55 in. (75 x 75 x 14 mm)
NOTE: The terminals are designed to handle a cross-section of
wire measuring 0.33 to 3.1 mm
2
.
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two­year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the nearest location.
If you have any questions concerning the installation of the PB130-230 power base, contact our technical support team at:
705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8
Tel.: (450) 358-4600 Toll Free: 1-800-831-AUBE Fax: (450) 358-4650 Email: service@aubetech.com
10 rue Ampère 95500 Gonesse France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19 advaube@comintes.com
For more information on our products, visit us at
www.aubetech.com
Introduction
The PB130-230 power base is used to power a TH13x Series control module. The resistive load must not exceed 3450 watts (NI) @ 230 VAC (15 A).
Installation Guidelines
Turn off power to the heating system at the main power panel to avoid electrical shock. Installation should be carried out by an electrician.
ߧ
All work must conform to the applicable country standards for electrical installations and wiring.
ߧ
This thermostat should be connected on a circuit equipped with a fuse or a circuit breaker. It must be installed on a certified electrical box.
ߧ
For a new installation, choose a location about 1.5 m above the floor.
ߧ
For electric baseboards, convectors and fan-forced heaters, the thermostat must be installed facing the heating system.
ߧ
The thermostat must be installed on an inside wall.
ߧ
Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.
n Remove the screw holding the
control module to the power base and lift the lower part upwards. The screw cannot be completely removed.
o Before making the connections, make sure
that the base covers the electrical box entirely. If not, install a wall plate at the back of the base as shown.
p Connect the wires:
Power:
Terminals 1 & 5
Load:
Terminals 2 & 4 see note 1
Pilot Wire:
Terminal 3 see note 2
Floor sensor:
Terminals 6 & 7 (no polarity) see note 3
Note 1 If a contactor is used between the thermostat and the load,
install a snubber at the contactor’s coil terminal to ensure the proper operation of the thermostat.
Note 2 This connection is required on some models only. Note 3 For the proper operation of the thermostat, the floor sensor
must be centered between two heater wires having a maximum temperature of 80°C. The floor sensor wire must not cross any heater wire or be placed close to it.
r Push wires into the electrical box and
secure the base to the electrical box anchorage. The head of the screw must be less than 2 mm thick.
s BEFORE installing the control
module onto the base, set the configuration switches (if any) on the control module (refer to the
user guide).
WARNING: This power base must be
used only with 15-minute heating cycles. If your control module has a selector switch for choosing the heating cycle, ensure that the switch is correctly set.
t Return power to the heating system.
12/8/04 400-130-001-D