Atwood LP_DOW, LP_DOB, LP_AOB, LP_AOW, LP_DRW User Manual And Installation Instructiions

...
Atwood Mobile Products LLC
1120 North Main Street Elkhart, IN 46614-3203
USA & Canada 1-866-869-3118
Internet: http://www.atwoodmobile.com
Model LP
USER’S MANUAL AND INSTALLATION
TESTED TO UL1484
For questions concerning your Alarm, please call our
Customer Service at 1-866-869-3118
Please have the following information ready when calling:
Alarm Model Number (located on the back of alarm):
Alarm Assembly Number (located on the back of alarm):
Date of Manufactured (located on the bottom of alarm):
Date of Purchase:
Where Purchased:
2
Liquefied Petroleum Gas Awareness ...............................................3
ACTIVE ALARM PROCEDURES .......................................................4
TESTING ............................................................................................6
MODEL DESCRIPTION ......................................................................7
SPECIFICATIONS ................................ ................................ ..............7
POWER CONSERVATION MODE ...................................................................... 8
ALARM OPERATION ......................................................................... 8
Power Off Mode ................................................................................................... 8
Normal Stand-by Mode ....................................................................................... 8
Alarm Mode .......................................................................................................... 9
Test Mode ............................................................................................................. 9
Silence / Stabilization Mode............................................................................... 9
Fault Mode ............................................................................................................ 9
FUNCTIONS ....................................................................................... 10
INSTALLATION INSTRUCTIONS .......................................................11
WIRING...............................................................................................13
FLUSH MOUNTING ............................................................................14
SURFACE MOUNTING .......................................................................15
AC Power Adapter Mounting ............................................................................. 15
OPERATING INSTRUCTIONS............................................................16
DETECTOR TEST ..............................................................................16
Lp Gas Detection ................................................................................................. 16
POWER MANAGEMENT ....................................................................16
Power Failure ....................................................................................................... 17
END OF LIFE ................................ ...................................................... 17
WARRANTY ....................................................................................... 18
3
READ ENTIRE MANUAL BEFORE USING THIS ALARM
Your new Atwood Propane (LP) alarm is a sophisticated instrument that has been carefully designed and tested to detect LP build up in a residential or recreation vehicle environment. Liquefied Petroleum (LP or Propane) gas can cause hazardous conditions when found in high concentrations. Gas is known to be found in recreational vehicles and the proper detection of this gas provides a safe environment for the occupants of the vehicle.
THIS ALARM HAS A SEVEN YEAR LIFE, SEE END OF LIFE
NOTIFICATION
Liquefied Petroleum Gas Awareness
LP gas is commonly called Propane and is sold commercially as a suitable fuel in portable and permanent heating and cooking appliances. It is important to detect LP gas due to its explosiveness at concentrated volumes. This detector is design to alarm at <25% LEL (legal explosive limit).
SAFETY ALERT SYMBOLS Safety symbols alerting you to potential personal safety hazards, Obey all safety messages following these symbols.
WARNING
Avoid possible injury or death
CAUTION
Avoid possible injury and/or property
damage
4
CAUTION
This alarm will only indicate the presence of gas at the sensor. Gases may
be present in other areas. Read this entire manual before using the alarm.
ACTIVE ALARM PROCEDURES IF ALARM SIGNAL SOUNDS:
1. Operate Test/Reset button;
1. Immediately move to fresh air-outdoors or by an open door/window. Do a head count to check that all persons are accounted for: Do not re-enter the premises move away from the open door/window until the emergency services responders arrive, the premises have been aired out, and your alarm returns to its normal condition.
2. Call your local Emergency Services Number or 911 ( )
Fill in your local Fire Department number here
3. After following steps 1 & 2, if your alarm reactivates within a 24 hour period, repeat steps 1 & 2 and call a qualified appliance technician
( ) Too investigate for sources of LP from fuel burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection, have equipment serviced immediately. Note any combustion equipment not inspected by technician consult the manufacturer’s Instructions, or contact the manufacturers directly, for more information about LP safety. Make
5
sure that motor vehicles are not, or have not been operating in an enclosed area or in close proximity of other vehicles.
Note: two self-adhesive emergency contact labels are provided. The user must add telephone numbers for the local emergency service provider and for a qualified service technician. User must place one label next to the alarm. The other label must be placed near a source of fresh air where you plan to gather in the event the alarm indicates propane is presence.
WARNING
Test Alarm operation after vehicle has been in storage, before each trip,
and at least once per week during use.
WARNING
Activation of this device indicates the presence of LP gas, which can cause an explosion and/or fire. This normally indicates a leak in the LP gas piping
or an LP gas appliance.
WARNING: If the information in this manual is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of
life
WHAT TO DO IF YOU SMELL GAS
Evacuate all persons from vehicle. Shut off gas supply at gas container or source. Do not touch any electrical switch, or use any phone or radio in
6
vehicle.
Do not start vehicle’s engine or electric generator. Contact nearest gas supplier or qualified Service Technician for
repairs.
If you cannot reach a gas supplier or qualified Service Technician,
contact the nearest fire department.
Do not run on gas supply until gas leak(s) have been repaired.
TESTING
Note: Unit must be powered for three minutes before test can be performed.
The Test/Rest button is used to verify proper alarm operation. Executing the test function sounds the alarm and lights up the LED. The test will
sound the alarm twice, with 4 “beeps” in 1 second followed by 5 seconds of
silence. By pressing the button, you can verify that the alarm sounds and that the LED functions properly. The alarm is internally monitored while powered to ensure proper operation and to detect faults.
Important
This detector will only indicate the presence of LP gas at the sensor.
Gases may be present in other areas.
The detector is not suitable as a smoke or fire detector. Not suitable