manual carefully. Otherwise, it may result in
personal injuries or equipment damage.
Never run the generator indoors or in an
enclosed area to avoid harm or possible death
from exhaust emissions of poisonous carbon
monoxide gas.
• Be careful not to touch the exhaust system
during operation because it can cause burns.
• Pay attention to the warning labels because
the engine exhaust system will become
heated during operation and remain hot
immediately after the engine is stopped.
IMPORTANT INFORMATION
Thank you for purchasing this ATOMIC
Power Gen Generator.
This manual covers the safety, operation and
maintenance procedures for the ATP5000XE
and ATP6500XE.
All information in this publication is based on
the latest product information available at the
time of print. No part of this publication may be
reproduced without written permission.
Please keep this manual together with
the generator.
This generator is designed to give safe and
dependable service if operated according to the
user manual.
It is important that anyone operating this product
read and understand the manual prior to use.
Failure to do so could result in personal injury or
equipment damage.
• Unleaded petrol is a highly flammable and
explosive liquid. Refuel in a well ventilated
area with the engine stopped.
• When refuelling the generator, keep it
away from cigarettes, open flames,
smoke and/or sparks.
• It is recommended that this generator not
be connected for stand-by power to any
household or building electrical circuit.
Improper connections can allow electrical
current from the generator to feed back into
the utility lines and may electrocute persons
contacting the lines during a power outage.
When the utility power is restored, the
generator may explode or cause fires.
• Do not connect the generator to an ATS
automatic transfer switch.
• Place the generator at least 1 metre
away from buildings or other equipment
during operation.
• Run the generator on a level surface. If the
generator tilts, fuel spillage may result.
2
• Know how to stop the generator quickly and
understand the operation of all the controls.
Never permit anyone to operate the generator
without proper instructions.
• Keep children and pets away from the
generator during operation.
• Do not operate the generator in rain,
wet conditions or snow.
• Do not allow any moisture to come in contact
with the generator.
• Do not touch the spark plug while the
generator is operating or shortly
after the generator has been shut down.
SAFETY GUIDELINES
Before connecting any appliances to
the generator:
• Make sure the appliance is turned off.
Faulty appliances or damaged power
cords can lead to an electrical shock.
• Turn off the generator immediately
if the appliance begins to operate
abnormally. Disconnect the appliance
and investigate the problem.
• Make sure that the electrical rating of the
appliance does not exceed that of the
generator. If the power level of the appliance
is between the maximum output power
and the rated power of the generator, the
generator should not be used for more than
30 minutes.
• Do not connect the AC outlets of the
generator to any household or building
circuits. Improper connections may lead to
a fire hazard or damage to the generator.
MAINTENANCE SAFETY
• Do not clean the air filter element with
flammable liquids like petrol because
an explosion may occur.
• Turn off the generator before performing any
maintenance. Otherwise it can cause severe
personal injury or death.
• Allow the generator to cool down before
performing any maintenance.
• Do not clean the generator with a pressure
washer because it may cause damage.
• Before working with batteries, ventilate
the area, wear safety glasses. Do not smoke
and always disconnect the negative cable
first and reconnect it last.
• Always stop the generator set before
removing the oil filler dip stick.
• Only qualified maintenance personnel
with knowledge of fuels, electricity,
and machinery hazards should perform
maintenance procedures.
WARRANTY STATEMENT
Primus Australia warrants this product against
defects for 12 months/500 hours (whatever
period expires first), commencing from the date
of purchase and is for the original owner only
and cannot be transferred.
For all warranty service and repairs
contact 1300 555 197 toll free.
Proof-of-purchase or a sales receipt clearly
showing the date and details of the purchase is
required for all warranty service or repair.
Primus Australia will repair or replace the
product, at its discretion, should a warrantable
defect arise within the warranty period. If the
exact model is unavailable a model of equivalent
value or features will be substituted at our
discretion. This warranty excludes faults and
failures caused by improper use and abuse; fair
wear and tear; or failure to follow instructions
regarding care and maintenance.
It is at the discretion of Primus Australia if a
warranty or replacement will be issued once the
product has been inspected by an authorised
repair agent and deemed to be a genuine
warranty.
Primus Australia will not be liable for any costs,
charges or expenses incurred in the process of
having the product returned to the place of purchase
in order to request a warranty unless agreed to in
writing prior to the product being returned.
For a copy of the warranty policy please visit
our website www.primusaustralia.com.au
Alternatively email service@primusaustralia.com.au
for further information.
Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for
a major failure and for compensation for any
other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a
major failure.
3
IDENTIFICATION OF COMPONENTS
ATP5000XE
ATP6500XE
FRONT
Air
Filter
Choke
Lever
Fuel
Gauge
Lift Hoist
Bracket
Long Range
Fuel Tank
ATP5000XE
ATP6500XE
REAR
Fuel
Tap
Anti-sink
Base Plate
Recoil
Starter
Handle
Oil
Dipstick
Battery
Front
Panel
Spark
Plug
AlternatorSpark
4
Exhaust
Cover
Carburettor
Arrestor
CONTROL PANEL
ATP5000XE
ATP6500XE
Digital
Meter
Economy
Control Idle SpeedDC Protector
Electric Key Start
Battery
Charging
12V DC
Socket
Master Circuit
Breaker
Low
Oil Light
IP66 Weather
Rated 15Amp
240V AC Socket
Ground
Terminal
Red Indicator
Light
Individual
RCD/MCB
(Residual
current
device/
miniature
circuit
breaker)
PRE-OPERATION INSPECTION
Exhaust gas contains poisonous carbon
monoxide. Do not run the generator in an
enclosed area. Be sure to provide adequate
ventilation. Operate the generator on a level
surface. If the generator is tilted, fuel spillage
may result in fire.
The generator is air-cooled and may be
damaged if ventilation is inadequate.
Inspect the engine oil before use. Engine oil
is a major factor affecting the performance
and service life of this product.
Non-detergent, 2 stroke engine oil or
vegetable oils are not recommended.
CHECKING OIL LEVEL
• Remove the oil filler dipstick and clean.
• Check the oil level by reinserting the oil
filler dipstick. Remove and examine the oil
level. If the level is at or below the lower
level mark, refill the oil to the upper limit
mark. Use 10W30 or 15W40 oil for all three
generator models covered in this manual.
• Reinsert the oil filler dipstick and
tighten securely.
Running the engine with insufficient oil
can cause serious damage to the engine
and other important components.
When the oil level is low, the Low Oil Light
on the control panel will illuminate and the
engine will automatically shut down. Do not
restart the generator until the oil level has
been adjusted.
CHECKING FUEL LEVEL
• Use only clean, fresh unleaded petrol.
Do not use E10 (Ethanol) fuel.
• Check the fuel level by reading the
gauge or removing the fuel tank cap
to visually inspect.
• Add fuel if level is too low. Do not refuel
while generator is running. Tighten the
cap securely after filling.
5