Atmor AT90008, AT90013, AT90010, AT90004, AT90006 User Manual

...
Page 1
Hot Water on Demand
Installation and Operation Guide
900 Series InLine
3kW-13kW
www.atmor.net
Page 2
Safety Instructions
OVERVIEW
This manual must be read carefully before attempting to install the water heater. If you do not follow the safety rules or the instructions outlined in this manual, the unit may not operate properly and it could cause property damage, serious bodily injury or death.
Atmor will not be liable for any damages because of failure to comply with the installation and operating instructions outlined in this manual or because of improper use. Improper use includes the use of this appliance
to heat any liquid other than water. Failure to comply with the installation and operating instructions or
improper use voids the warranty. Never remove the unit’s cover unless the electricity is turned off.
01
The water heater must be installed by a licensed electrician and in compliance with all local electrical and building regulations.
04
The heater must be installed according to the installation
instructions (see gures).
07
The plumbing installation requires metal or reinforced pipes that can withstand a minimum pressure of 8 bar. (Other types of pipes will
cause damage.)
02
Caution: The appliance must be grounded.
05
The plumbing installation must be completed before the electrical installation.
08
Do not install the heater where it may be subjected to direct sunlight, rain and/ or a constant spray of water.
03
A dedicated circuit breaker must be installed on the power distribution panel.
06
The heater operates at a
minimum water ow rate of
0.5 gallon/minute.
09
Always contact your local authorized licensed proffessional for service.
1
Page 3
Technical Information
Model *Wattage Voltage Amperage Phase
AT900-03 3 kW 110 27 1 30 10 AWG
AT900-04 3.8 kW 240 16 1 20 12 AWG
AT900-06 6.5 kW 240 27 1 30 10 AWG
AT900-08 8.5 kW 240 36 1 40 6 AWG
AT900-10 10.5 kW 240 44 1 50 6 AWG
AT900-13 13 kW 240 55 1 60 4 AWG
Minimum water ow to activate unit: 0.5 GPM Nominal water volume: 2.7G/Min Working pressure: 0.5 -8 bar (7 -115 psi) Tested pressure: 16 bar (230 psi) Water connections: 1/2" NPT Dimensions (in) (H x W x D): 7.3 x 11.8 x 3.55 Weight (Ib): 3.4
* Wattage based on maximum voltage.
Circuit breaker
size
Model Guide - kW Output
Model 240V 208V 110V 120V
AT900-04 3.8 kW 2.8 kW - -
Required wire
size
AT900-06 6.5 kW 4.9 kW - -
AT900-08 8.5 kW 6.4 kW - -
AT900-10 10.5 kW 7.9 kW - -
AT900-13 13.0 kW 9.8 kW - -
AT900-03 - - 3.0 kW 3.5 kW
2
Page 4
Assembly Instructions
01
Connect the Pressure Relief
Device (PRD) to the unit (Fig1)
Note: IMPORTANT – do not discard this step. A PRD must be installed.
Mount unit to wall with 4 screws at the
marked points (Figure 4)
04
05
The appliance must be mounted horizontally, with water inlets and outlets
at the bottom (Figure 5)
Connect the water inlet hose to the entry point of the heater (left side
inlet), and connect the outlet hose to the water outlet. Use a hose that can withstand a minimum pressure of 4 bars. Using any other type of hose will cause damage (Figure 5).
Residential plumbing systems with unstable pressure or pressure above 5 bar require the application of a pressure stabilizer valve, set to 4 – 5 bars.
Do not install the appliance with water inlets and outlets at the
top (Figure 6)
02
Remove the appliance
covers (Figure 2).
03
1. Mount ground plate to wall.
2. Pull wires through.
3. Cut out hole in back of unit (Right/Left
back) and pass wires
through
(Figure 3)
06
3
Page 5
1
Rubber
PRD
Cold Hot
2
*
3 4
*3a) 3kW
L1 L2 N
L1
N
**
*3b)
3.5-8.5kW
L1GGN
G = Green or Yellow N = White L1/L2 = Black
L1G
L2
GNL1
*3c)
8.6-13kW
65
Note: Neutral (N) does not need to be connected.
L1
(L2)
L2
N
L1
4
Page 6
07
Run the water ow for
one minute to check for leakage before connecting to power.
08
Connect the power cable to the terminal block. Caution: The heater must be grounded.
Reference gure *3 on page 4 and
Electrical diagram on page 6
1009
Reattach the front cover of the heater and secure it with 4 screws and then slide the bottom gray cover
12
Do not install the heater where it may be subject to direct sunlight.
Aerator provided with 3kW models only
Assembly instructions
Make sure that the
appliance is lled with
water before connecting
power. (Repeat step 7)
13
14
For optimal heating performance and proper operation, the provided 0.5GPM aerator must be installed to your sink faucet. This will ensure
a continuous ow and consistent, maximum
temperature rise. Output temperature will vary depending on seasonality and inlet cold water temperatures
11
When installed outdoors, the heater must be placed in sealed waterproof electrical box.
It is recommended that the appliance electrical connections be tested once
a year by a qualied technician.
Maximum of 0.5 GPM ow rate is needed for optimal heating performance
5
Page 7
Electrical Diagram
1. 3-3.4kW (110V) - Install Line 1 (L1), E(G)-Ground, N (Neutral)
2. 3.5-8.5kW (240V) - Install Line 1 (L1), E(G)-Ground, Line 2 (L2)
1
L
E(G)
N
1
L1
E(G)
L2(*N)
8.6kW-10.5kW (240V)
L N
E(G)
L1
L2(*N)
E(G)
10.6kW-13kW (240V)
411 53 6
78
3
1. Terminal block
2. Thermal cut-out with reset
3. Thermal cut-out
4. Relay
5. Light
6. Switch 0- Off
(Option) 1- Low
7. Heating element
8. Read sensor
1. Terminal block
2. Thermal cut-out with reset
3. Thermal Cut out
4. Relay
5. Switch 0- Off 1- Low 2- Medium 3- High
6. Heating element
7. Read sensor
8. EARTH(G) Connection in
the heating canister
L
N
E (G)
L1
L2(*N)
E(G)
1
1
2 7
8
5 64
L1/L2 = Line1/Line2 (Black or Red) E(G) = Ground (Green/Yellow)
*N = Neutral (White or Silver)
*Neutral acts as Line 2 (L2) for 220V/240V *Neutral does not have to be connected for 3.5kW-13kW
1. Terminal block
2. Thermostat with reset
3. Thermostat
4. Switches with lights
5. Relay
6. Heating elements
7. Read sensor
8. EARTH(G) Connection in
the heating canister
6
Page 8
Operation Guide
Low Medium High
MODEL kW kW kW
AT900-03 1 2 3
AT900-04 1.6 2.2 3.8
AT900-06 3 3.5 6.5
AT900-08 3.8 4.7 8.5
AT900-10 5.25 5.25 10.5
AT900-13 4.5 8.5 13
Troubleshooting
PROBLEM ISSUE POSSIBLE CAUSE SOLUTION
Water not hot enough.
Too much water owing
through the heater.
Reduction in the ambient temperature.
Water Pressure below of
0.5 bar (7 psi).
Electrical Malfunction.
Reduce the ow rate of the water via
the outlet tap.
Switch to higher temperature setting.
Check if the main water line stop valve is fully open and that there are no other restrictions in the water supply line.
Have the Heater unit check by a
qualied eIectrician or contact your
local authorized distributor.
7
Page 9
Troubleshooting
PROBLEM ISSUE POSSIBLE CAUSE SOLUTION
Water too hot. Not enough water owing
Heater shut off during use.
Water ceases to
ow.
Water temperature varies from hot to cold during use.
No hot water/Unit is not working.
through the heater.
Increase in the ambient temperature.
Interruption of main electrical supply.
Blockage of your hand held shower head.
No water supply.
Water pressure has dropped below min. level.
No electrical power.
Low ow rate 0.5 bar (7 psi).
Increase the ow rate via the outlet
tap.
Switch to lower temperature setting.
Check incoming power supply, MCB, switches and supply cabling.
If problem persists, call your local authorized distributor for assistance.
Clean or replace your hand held shower head. Check to see that your shower head hose is not twisted or blocked. It is necessary for the hose to have a free passage of water.
Check if the main water line stop valve is fully open and that there are no other restrictions in the water supply line.
Increase hot water supply.
Check the circuit breaker and check voltage at the wiring block.
Clean lter screen:
1. Turn circuit breaker off.
2. Open the valve to release pressure from the unit.
3. Turn circuit breaker on.
If you have an issue and need further assistance,
please call: 1-888-783-6082
8
Page 10
Parts
1. Switches
9
2. PRD
3. Cold water inlet
5. Hot water outlet (to be connected to the main hot
water pipe)
Page 11
10
Page 12
LIMITED WARRANTY
The terms of this warranty is solely subject to the original owner and is at no time transferable. A transfer of ownership will result in an immediate termination of this warranty. This warranty is valid only if product is purchased from an authorized reseller.
Atmor warrants to the original owner that our instant water heaters will be free from defect in workmanship and material for a period of TWO YEARS from the date of purchase, and free from
leakage for a period of SEVEN YEARS from the date of purchase. Should any part(s) prove to be defective during this period, Atmor will be responsible for replacement of the defective part(s) only.
Atmor is not responsible for labor charges or any incidental or consequential expenses. Atmor’s liability is limited to the cost of the product or $1,000.00, whichever is less. Atmor is not an insurer and the original owner should purchase insurance to cover damage to property or belongings. The original owner agrees to waive their right to jury trial or to participate in a class action. In addition, the original owner agrees to waive subordination to the extent a loss is covered by insurance, so that their insurance company cannot proceed with action against Atmor for recovery of any claims. Furthermore, all claims must be arbitrated in the state of New Jersey.
Should the owner wish to return the water heater for repair, the owner must rst secure a written
authorization from Atmor. The owner shall be required to show proof of purchase date and to pay
all transportation costs to return the defective part(s) or water heater for repair or replacement. Warranty is void if: (i) water heater has been installed or used improperly; (ii) design has been altered in any way; (iii) water heater has been installed and/or serviced by someone other than a licensed electrician ; (iv) or if the water heater has been
installed or used in contradiction to installation instructions, applicable laws and/or ordinances.
A full and complete version of this warranty is available on the online, www.atmorusa.com, or upon request from an Atmor representative
Distributed by:
PARAGON GROUP USA LLC
Englewood, NJ 07631
USA
Phone: 1-888-783-6082 Email: info@paragongroupusa.com Web: www.atmorusa.com
Page 13
Hot Water on Demand
Instalación y guía de funcionamiento
Serie InLine 900
3kW-13kW
www.atmor.net
Page 14
Instrucciones de seguridad
Información técnica
Guía del modelo – Salida en kW
2
Modelo *Vataje Voltaje Amperaje Fase
Tamaño del
disyuntor
Tamaño de cable
requerido
AT900-03 3 kW 110 27 1 30 10 AWG
AT900-04 3.8 kW 240 16 1 20 12 AWG
AT900-06 6.5 kW 240 27 1 30 10 AWG
AT900-08 8.5 kW 240 36 1 40 6 AWG
AT900-10 10.5 kW 240 44 1 50 6 AWG
AT900-13 13 kW 240 55 1 60 4 AWG
Flujo mínimo de agua para activar la unidad: 0.5 GPM Volumen de agua nominal: 0.11 galones (0.42 l) Presión de funcionamiento: de 0.5 a 8 bares (de 7 a 115 psi) Presión probada: 16 bares (230 psi) Conexiones de agua: 1/2" NPT Dimensiones (pulg.) (A x A x P): 7.3 x 11.8 x 3.55 Peso (libras): 3.4
Modelo 240 V 208 V 110 V 120 V
AT900-04 3.8 kW 2.8 kW - -
AT900-06 6.5 kW 4.9 kW - -
AT900-08 8.5 kW 6.4 kW - -
AT900-10 10.5 kW 7.9 kW - -
AT900-13 13.0 kW 9.8 kW - -
AT900-03 - - 3.0 kW 3.5 kW
* El vataje se basa en el voltaje máximo.
DESCRIPCIÓN GENERAL
Este manual se debe leer atentamente antes de intentar instalar el calentador de agua. Si usted no cumple las reglas de seguridad o las instrucciones detalladas en este manual, la unidad puede no funcionar adecuadamente y puede causar daños a la propiedad, lesiones corporales graves o la muerte.
Atmor no será responsable de los daños ocasionados por no cumplir las instrucciones de instalación y funcionamiento detallados en este manual o por el uso inadecuado. El uso inadecuado incluye el uso de este artefacto para calentar cualquier líquido que no sea agua. No cumplir las instrucciones de instalación y funcionamiento o usar el artefacto de manera
inadecuada anula la garantía. Nunca retire la cubierta de la unidad a menos que la electricidad esté desconectada.
01
El calentador de agua debe ser instalado por un electricista certificado y en conformidad con todas las regulaciones locales en materia de electricidad y edificios.
04
El calentador se debe instalar de acuerdo con las instrucciones de instalación (ver las figuras).
02
Precaución: el artefacto se debe conectar a tierra.
05
La instalación de plomería se debe completar antes de la instalación eléctrica.
03
06
Se debe instalar un disyuntor dedicado en el panel de distribución de la alimentación.
El calentador funciona a una tasa de flujo mínima de
0.5 galones/minuto.
07
La instalación de plomería requiere tuberías reforzadas o metálicas que puedan soportar una presión mínima de 8 bares. (Otros tipos de tuberías causarán daños).
08
No instale el calentador donde pueda estar expuesto a la luz solar directa, la lluvia o el rocío constante de agua.
09
Siempre comuníquese con su profesional local autorizado y certificado para realizar el mantenimiento.
1
Page 15
Información técnica
Guía del modelo – Salida en kW
2
Modelo *Vataje Voltaje Amperaje Fase
Tamaño del
disyuntor
Tamaño de cable
requerido
AT900-03 3 kW 110 27 1 30 10 AWG
AT900-04 3.8 kW 240 16 1 20 12 AWG
AT900-06 6.5 kW 240 27 1 30 10 AWG
AT900-08 8.5 kW 240 36 1 40 6 AWG
AT900-10 10.5 kW 240 44 1 50 6 AWG
AT900-13 13 kW 240 55 1 60 4 AWG
Flujo mínimo de agua para activar la unidad: 0.5 GPM Volumen de agua nominal: 0.11 galones (0.42 l) Presión de funcionamiento: de 0.5 a 8 bares (de 7 a 115 psi) Presión probada: 16 bares (230 psi) Conexiones de agua: 1/2" NPT Dimensiones (pulg.) (A x A x P): 7.3 x 11.8 x 3.55 Peso (libras): 3.4
Modelo 240 V 208 V 110 V 120 V
AT900-04 3.8 kW 2.8 kW - -
AT900-06 6.5 kW 4.9 kW - -
AT900-08 8.5 kW 6.4 kW - -
AT900-10 10.5 kW 7.9 kW - -
AT900-13 13.0 kW 9.8 kW - -
AT900-03 - - 3.0 kW 3.5 kW
* El vataje se basa en el voltaje máximo.
2.7G/Min
Page 16
Instrucciones de ensamblaje
01
Conecte el dispositivo de alivio de presión a la unidad (Fig. 1).
Nota: IMPORTANTE – No omita este paso. Se debe instalar un dispositivo de alivio de presión.
Instale la unidad con los 4 tornillos en los puntos marcados (Figura 4).
04
05
El artefacto se debe instalar horizontalmente, con las entradas y salidas de agua en la parte inferior (Figura 5).
Conecte la manguera de entrada de agua al punto de entrada del calentador (entrada del lado izquierdo) y conecte la manguera de salida a la salida de agua. Use una manguera que pueda soportar una presión mínima de 4 bares. El uso de cualquier otro tipo de manguera causará daños (Figura 5).
Los sistemas de plomería residenciales con una presión inestable o una presión que supere los 5 bares requieren la aplicación de una válvula estabilizadora de presión, fijada en 4 a 5 bares.
No instale el artefacto con las entradas y salidas de agua en la parte superior (Figura 6).
02
Retire las cubiertas del artefacto (Figura 2).
03
1. Instale la placa de tierra a la pared.
2. Jale los cables.
3. Corte el orificio en la parte posterior de la unidad (Derecha/Izquierda posterior) y pase los cables
(Figura 3).
06
3
Page 17
1
Goma
Dispositivo de alivio de
presión
Frío Caliente
2
*
3 4
*3a) 3kW
L1 L2 N
L1
N
G = Verde o amarillo N = Blanco L1/L2 = Negro
**
*3b)
3.5-8.5kW
L1GGN
65
*3c)
8.6-13kW
L1G
L2
GNL1
(L2)
L2
N
Nota: el neutro (N) no requiere conexión.
L1
L1
4
Page 18
Conecte el cable de alimentación al bloque
6
Diagrama eléctrico
1. Bloque de terminales
2. Interruptor térmico con reajuste
3. Interruptor térmico
4. Relé
5. Luz
6. Interruptor 0- Apagado (Opción) 1- Bajo
7. Resistencia
8. Sensor de lectura
1. Bloque de terminales
2. Interruptor térmico con reajuste
3. Interruptor térmico
4. Relé
5. Interruptor 0- Apagado 1- Bajo 2- Medio 3- Alto
6. Resistencia
7. Sensor de lectura
8. TIERRA (G) Conexión en el recipiente calentador
411 53 6
198
L1
L2(*N)
E(G)
L N
E(G)
1
1
L
E(G)
N
L1 E(G) L2(*N)
1. Bloque de terminales
2. Termostato con reajuste
3. Termostato
4. Interruptores con luces
5. Relé
6. Resistencias
7. Sensor de lectura
8. TIERRA (G) Conexión en el recipiente calentador
L1 L2(*N) E(G)
5 64
1 2 7
3
L
N
E (G)
8
1
8.6kW-10.5kW (240V)
10.6kW-13kW (240V)
1. 3-3.4 kW (110 V) - Instalar Línea 1 (L1), E(G)-Tierra, N (Neutro)
2. 3.5-8.5 kW (240 V) - Instalar Línea 1 (L1), E(G)-Tierra, Línea 2 (L2)
L1/L2 = Línea 1/Línea 2 (Negro o Rojo) E(G) = Tierra (Verde/Amarillo) *N = Neutro (Blanco o Plata)
*El neutro actúa como Línea 2 (L2) para 220 V/240 V *El neutro no requiere conexión para 3.5 kW-13 kW
de terminales.
07
Deje correr el agua durante un minuto para verificar si hay fugas antes de conectar el artefacto al suministro eléctrico.
Vuelva a colocar la cubierta frontal del calentador y asegúrela con 4 tornillos, y luego deslice la cubierta gris inferior.
08
Precaución: el calentador debe estar conectado a tierra. Consulte la figura 3 en la página 4 y el diagrama eléctrico en la página 6.
1009
Asegúrese de que el artefacto esté lleno de agua antes de conectar el suministro eléctrico. (Repita el paso 7).
11 12
Cuando el sistema se instala al aire libre, el calentador se debe colocar en una caja eléctrica sellada a prueba de agua.
Se recomienda que las conexiones eléctricas del artefacto sean probadas una vez al año por un técnico certificado.
13
5
No instale el calentador donde pueda estar expuesto a la luz solar directa.
Page 19
Diagrama eléctrico
1. 3-3.4 kW (110 V) - Instalar Línea 1 (L1), E(G)-Tierra, N (Neutro)
2. 3.5-8.5 kW (240 V) - Instalar Línea 1 (L1), E(G)-Tierra, Línea 2 (L2)
1
L
E(G)
N
1
L1 E(G) L2(*N)
8.6kW-10.5kW (240V)
L N
E(G)
L1
L2(*N)
E(G)
10.6kW-13kW (240V)
L
N
E (G)
L1 L2(*N) E(G)
411 53 6
198
3
1. Bloque de terminales
2. Interruptor térmico con reajuste
3. Interruptor térmico
4. Relé
5. Luz
6. Interruptor 0- Apagado (Opción) 1- Bajo
7. Resistencia
8. Sensor de lectura
1. Bloque de terminales
2. Interruptor térmico con reajuste
3. Interruptor térmico
4. Relé
5. Interruptor 0- Apagado 1- Bajo 2- Medio 3- Alto
6. Resistencia
7. Sensor de lectura
8. TIERRA (G) Conexión en el recipiente calentador
1. Bloque de terminales
2. Termostato con reajuste
3. Termostato
4. Interruptores con luces
5. Relé
6. Resistencias
7. Sensor de lectura
8. TIERRA (G) Conexión en el recipiente calentador
1 2 7
1
8
L1/L2 = Línea 1/Línea 2 (Negro o Rojo) E(G) = Tierra (Verde/Amarillo) *N = Neutro (Blanco o Plata)
*El neutro actúa como Línea 2 (L2) para 220 V/240 V *El neutro no requiere conexión para 3.5 kW-13 kW
5 64
6
Page 20
Guía de funcionamiento
Resolución de problemas
8
PROBLEMA CAUSA POSIBLE SOLUCIÓN
El agua está No fluye suficiente agua por demasiado caliente. el calentador.
La temperatura ambiente aumentó.
Incrementar la tasa de flujo mediante la llave de salida.
Cambiar a un ajuste de temperatura más bajo.
El calentador se apaga durante el uso.
Interrupción del suministro eléctrico.
Revisar el suministro de energía, disyuntor, interruptores y cableado.
Si el problema persiste, comuníquese con su distribuidor local autorizado para obtener asistencia.
El agua deja de correr.
Bloqueo del cabezal de la ducha.
Interrupción del suministro de agua.
Limpiar o reemplazar el cabezal de la ducha. Verificar que la manguera del cabezal de ducha no esté retorcida o bloqueada. La manguera debe tener un libre paso de agua.
Verificar que la válvula de cierre de la línea de agua esté completamente abierta y que no existan otras restricciones en la línea de suministro de agua.
La temperatura del agua varía de caliente a fría durante el uso.
La presión del agua ha caído por debajo del nivel mínimo.
Aumentar el suministro de agua caliente.
No sale agua caliente/La unidad no funciona.
Falta de energía eléctrica.
Tasa de flujo baja, 0.5 bares (7 psi).
Verificar el disyuntor y el voltaje en el bloque de cableado.
Limpiar la rejilla del filtro:
1. Apagar el disyuntor.
2. Abrir la válvula para liberar la presión de la unidad.
3. Encender el disyuntor.
Si tiene un problema y necesita más asistencia,
llame al: 1-888-783-6082
Bajo Medio Alto
MODELO kW kW kW
AT900-03 1 2 3
AT900-04 1.6 2.2 3.8
AT900-06 3 3.5 6.5
AT900-08 3.8 4.7 8.5
AT900-10 5.25 5.25 10.5
AT900-13 4.5 8.5 13
Resolución de problemas
PROBLEMA CAUSA POSIBLE SOLUCIÓN
El agua no está lo suficientemente caliente.
Fluye demasiada agua por el calentador.
La temperatura ambiente disminuyó.
La presión del agua no alcanza los 0.5 bares (7 psi).
Desperfecto eléctrico.
7
Reducir la tasa de flujo del agua mediante la llave de salida.
Cambiar a un ajuste de temperatura más alto.
Verificar que la válvula de cierre de la línea de agua esté completamente abierta y que no existan otras restricciones en la línea de suministro de agua.
Hacer que un electricista certificado revise el calentador o comunicarse con su distribuidor local autorizado.
Page 21
Resolución de problemas
PROBLEMA CAUSA POSIBLE SOLUCIÓN
El agua está No fluye suficiente agua por demasiado caliente. el calentador.
La temperatura ambiente aumentó.
El calentador se apaga durante el uso.
El agua deja de correr.
La temperatura del agua varía de caliente a fría durante el uso.
No sale agua caliente/La unidad no funciona.
Interrupción del suministro eléctrico.
Bloqueo del cabezal de la ducha.
Interrupción del suministro de agua.
La presión del agua ha caído por debajo del nivel mínimo.
Falta de energía eléctrica.
Tasa de flujo baja, 0.5 bares (7 psi).
Incrementar la tasa de flujo mediante la llave de salida.
Cambiar a un ajuste de temperatura más bajo.
Revisar el suministro de energía, disyuntor, interruptores y cableado.
Si el problema persiste, comuníquese con su distribuidor local autorizado para obtener asistencia.
Limpiar o reemplazar el cabezal de la ducha. Verificar que la manguera del cabezal de ducha no esté retorcida o bloqueada. La manguera debe tener un libre paso de agua.
Verificar que la válvula de cierre de la línea de agua esté completamente abierta y que no existan otras restricciones en la línea de suministro de agua.
Aumentar el suministro de agua caliente.
Verificar el disyuntor y el voltaje en el bloque de cableado.
Limpiar la rejilla del filtro:
1. Apagar el disyuntor.
2. Abrir la válvula para liberar la presión de la unidad.
3. Encender el disyuntor.
Si tiene un problema y necesita más asistencia,
llame al: 1-888-783-6082
8
Page 22
Piezas
10
1. Interruptores
9
2. Dispositivo de alivio de presión
3. Entrada de agua fría
5. Salida de agua caliente (para conectar a la tubería de agua caliente)
Page 23
10
Page 24
GARANTÍA LIMITADA
Atmor garantiza al propietario original de nuestros calentadores de agua instantáneos la ausencia de
defectos de fabricación y material durante un período de DOS AÑOS a partir de la fecha de compra, y la
ausencia de fugas durante un período de SIETE AÑOS a partir de la fecha de compra. Si alguna pieza
resultara defectuosa durante este período, Atmor será responsable del reemplazo de la pieza defectuosa
únicamente. Atmor no se responsabilizará por los costos de mano de obra o cualquier gasto incidental o
consecuente.
Si el propietario desea devolver el calentador para su reparación, el propietario primero debe obtener una
autorización escrita de Atmor. Se requiere que el propietario muestre una prueba de la fecha de compra y
pague todos los costos de transporte para devolver la pieza defectuosa o el calentador para su reparación
o reemplazo. La garantía no será válida si: (i) el calentador de agua ha sido instalado o usado de manera
inadecuada; (ii) el diseño ha sido alterado de cualquier manera; (iii) la instalación o el mantenimiento del
calentador estuvo a cargo de una persona distinta de un electricista habilitado; (iv) o si el calentador ha sido
instalado o usado en contradicción con las instrucciones de instalación, las leyes u ordenanzas aplicables.
GARANTÍA LIMITADA
Los términos de esta garantía están únicamente sujetos al propietario original y en ningún momento
son transferibles. Una transferencia de propiedad resultará en la terminación inmediata de esta garantía. Esta garantía es válida sólo si el producto se adquiere de un distribuidor autorizado.
Atmor garantiza al propietario original de nuestros calentadores de agua instantáneos la ausencia
de defectos de fabricación y material durante un período de DOS AÑOS a partir de la fecha de compra, y la ausencia de fugas durante un período de SIETE AÑOS a partir de la fecha de compra.
Si alguna pieza resultara defectuosa durante este período, Atmor será responsable del reemplazo de la pieza defectuosa únicamente. Atmor no se responsabilizará por los costos de mano de obra o cualquier gasto incidental o consecuente. La responsabilidad de Atmor se limita al costo del producto o $ 1,000.00, lo que sea menor. Atmor no es una aseguradora y el propietario original debe comprar un seguro para cubrir los daños a la propiedad o pertenencias. El propietario original
se compromete a renunciar a su derecho a juicio por jurado oa participar en una acción colectiva. Además, el propietario original se compromete a renunciar a la subordinación en la medida en
que una pérdida está cubierta por el seguro, de modo que su compañía de seguros no puede
proceder con la acción contra Atmor para la recuperación de las reclamaciones. Además, todas las
reclamaciones deben ser arbitradas en el estado de Nueva Jersey.
Si el propietario desea devolver el calentador para su reparación, el propietario primero debe obtener una autorización escrita de Atmor. Se requiere que el propietario muestre una prueba de la fecha
de compra y pague todos los costos de transporte para devolver la pieza defectuosa o el calentador
para su reparación o reemplazo. La garantía no será válida si: (i) el calentador de agua ha sido instalado o usado de manera inadecuada; (ii) el diseño ha sido alterado de cualquier manera; (iii) la instalación o el mantenimiento del calentador
estuvo a cargo de una persona distinta de un
electricista habilitado; (iv) o si el calentador ha sido instalado o usado en contradicción con las instrucciones de instalación, las leyes u
ordenanzas aplicables.
Una versión completa de esta garantía está
disponible en línea, www.atmorusa.com, o bajo
petición de un representante de Atmor.
Distribuido por:
PARAGON GROUP USA LLC
15 Engle Street, 3rd Floor Englewood, NJ 07631 1-888-783-6082
Nuestro personal está preparado para asistirlo.
¡ALTO!
¡Primero llámenos y deje que
nuestro equipo de asistencia lo ayude!
NO DEVUELVA EL CALENTADOR
A LA TIENDA
¿Tiene preguntas acerca de su unidad
o necesita asistencia?
Llame al:
1-888-783-6082
o envíe un correo electrónico a:
info@paragongroupusa.com
De lunes a viernes, de
9 a.m. a 5 p.m. Hora Estándar del Este
P.N. 115045C
P.N. 197335C
Loading...