Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: sales@atlasfoodserv.com
PARTS LIST REFRIGERATED PASS THROUGH DISPLAY CASE
WCPT SERIES
2
10
3
4
5
6
7
1
WCPT-4
SHOW N
11
ITEM
NUMBER
1
2 7002-0+Model # Vinyl Bead Gasket
3 6151-5 Pilaster
4 6151-2 Thumbscrew
5 6151-1 Snap-In Shelf Supports
6 81-7990 Plexiglass Light Cover (White)
7
8 1003-0 Power Cord
9 1069-1 Compressor Switch
10 2060-1 Condensing Water Evaporator
11 1800-4212 1/2 H.P. Compressor
12 2013-0 Fan Motor (Not Shown)
13 S81441-0 Fan Guard (Not Shown)
14 2014-5 Fan Blade (Not Shown)
15 600010 Expansion Valve
PART
NUMBER
27-15 Door Set #3
27-20 Door Set #4
27-17 Wire Shelf #3
27-16 Wire Shelf #4
DESCRIPTION
8
9
ITEM
NUMBER
16 2119-0
17 113-10 Thermometer (Not Shown)
18 7019-2 Bulb Holder (Not Shown)
19 27-125 Light Switch (Not Shown)
20 1034-1 Ballast (Not Shown)
21 60-6056 Door Lock (Optional)
23
24
27-124 Door Seal (Not Shown)
25 22-2040 Low Pressure Control (Not Shown)
26 22-2036 Bracket (Not Shown)
27 2024 Drier (Not Shown)
680-63 Door Roller
1149 Fan Motor Wire Harness
PART
NUMBER
27-108 Mirror Door #3 (Optional) 22
27-107 Mirror Door #4 (Optional)
27-123 Door Spring #3 (Not Shown)
27-122 Door Spring #4 (Not Shown)
DESCRIPTION
Evaporator Coil #3 (Not Shown)
Evaporator Coil #4 (Not Shown)
REFRIGERATED PASS THROUGH DISPLAY CASE
WCPT SERIES
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
INSTALLATION
Provide the correct counter cut-out opening (see chart below) and drop unit in. The vinyl gasket assures complete
seating. A non-toxic silicon sealer may be used between the gasket and counter top (not required).
MODEL
WCPT-3 22 1/4" X 41 3/4"
WCPT-4 22 1/4" X 55 1/2"
The unit should be level for draining purposes. When installing unit in counter, it is recommended that the operator
side be completely open for air circulation. When this is not possible, such as in an island counter, it is
recommended that two grill openings are provided approximately 18” x 18” of free air for intake and exhaust at
opposite ends of counter.
The unit is supplied with a power cord and NEMA plug. Refer to the data plate located in the compressor housing
for the amperage and voltage information. Use a licensed electrician when installing power source.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
CUT-OUT
REQUIRED
OPERATION
The unit is ready to be operated as soon as it is plugged in and switched on. The unit has been pre-tested for proper
operation from 35 to 40 degrees.
-------------------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------------------------------------
MAINTENANCE
NEVER CLEAN THE UNIT WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER
CLEANING COULD SCAR, MARK AND/OR CORRODE METAL. DO NOT USE STEEL WOOL OR
ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE
ALL RESIDUES. CLEAN CONDENSER COIL REGULARLY.