COLD PAN REFRIGERATED AIR FLOW SYSTEM
WCM-BT SERIES
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment!
Notify carrier of damage! Inspect all components immediately. See page 1.
DROP-IN COLD PAN
REFRIGERATED, AIR FLOW SYSTEM
SELF-CONTAINED WITH DEFROST SYSTEM
Effective Date: 2017
IMPORTANT INFORMATION
READ BEFORE USE
CONTENTS
RECEIVING & INSPECTING EQUIPMENT....................................................................................................................................................................................1
SERIAL AND MODEL # LOCATION..............................................................................................................................................................................................1
WCM-BT - SPECIFICATIONS, FEATURES AND ACCESSORIES.............................................................................................................................................2
ELECTRICAL CHARACTERISTICS, CUT-OUT REQUIREMENTS AND REFRIGERATION CHART.................................................................................3
INSTALLATION, OPERATION AND S/S MAINTENANCE........................................................................................................................................................4
PARTS LIST..........................................................................................................................................................................................................................................5
TROUBLE SHOOTING GUIDE.........................................................................................................................................................................................................6
ELECTRICAL SCHEMATICS.............................................................................................................................................................................................................7
LIMITED WARRANTY........................................................................................................................................................................................................................8
WARRANTY INFORMATION...........................................................................................................................................................................................................9
RECEIVING AND INSPECTING THE EQUIPMENT
1. VISUALLY INSPECT THE SHIPPING CRATE. DAMAGE SHOULD BE NOTED AND REPORTED TO THE DELIVERING CARRIER.
2. IF DAMAGED, OPEN AND INSPECT CONTENTS WITH CARRIER.
3. IF CRATE IS NOT DAMAGED AND THERE IS CONCEALED DAMAGE TO THE EQUIPMENT, NOTIFY THE CARRIER. NOTIFICATION MUST BE
MADE VERBALLY AND IN WRITING.
4. REQUEST AN INSPECTION BY THE SHIPPING COMPANY FOR THE DAMAGED EQUIPMENT WITHIN 10 DAYS FROM RECEIPT OF THE
EQUIPMENT
5. FREIGHT CARRIERS CAN SUPPLY THE NECESSARY FORMS ON REQUEST.
6. SAVE ALL CRATING MATERIALS UNTIL INSPECTION HAS BEEN MADE OR WAIVED.
SERIAL NUMBER LOCATION
THE SERIAL AND MODEL# CAN BE FOUND ON THE CONDENSING UNIT ENCLOSURE - SEE OPERATORS SIDE CONTROL PANEL WHEN
CALLING ATLAS FOR PARTS AND SERVICE. ALWAYS HAVE THIS INFORMATION AVAILABLE.
SERIAL #: _______________________________________________________
MODEL #:_______________________________________________________
INSTALLATION DATE: _____________________________________________
Project: ___________
Item No.: ___________
Quantity: ___________
DROP-IN SERVING EQUIPMENT
COLD PAN
Refrigerated
Air Flow System
Self-Contained with
Defrost System
WCM-BT-4
SPECIFICATIONS
TOP: Constructed of 18 gauge, type 304 stainless steel, die
stamped with a raised perimeter bead. There shall be a solid
vinyl gasket under the beaded edge to form a seal to the
counter top, thus preventing seepage or marring of the
counter top. Embossed mounting lugs are provided along the
inner surface of the top to hold a full set of removable
separator channels in place.
LINER: The inner liner shall be 18 gauge, type 304 stainless
steel, one piece construction, all welded, ground and polished
to a uniform finish. All corners are coved with a minimum 1/4"
radius. A 3/4" dia. drain with strainer, 4" PVC nipple, and valve
is provided.
INSULATION: The pan is fully insulated with high density
polystyrene, 1" thick on all sides, 2" thick on the bottom and
enclosed with a 22 gauge galvanized steel outer case.
REFRIGERATION SYSTEM: The compressor housing shall
be fabricated from 14 gauge galvanized and bolted to the
base of the unit. A fully self-contained condensing unit is provided with a hermetically sealed compressor and a thermostat
control. The system is also provided with a forced air evaporator for even temperature throughout the pan that drains into a
condensate evaporator pre-wired in the unit. Automatic defrost
system is provided. The system is fully charged with CFC free
refrigerant and ready to operate.
NOTE: Proper ventilation must be provided in counter.
WCM-BT-3
WCM-BT-4
WCM-BT-5
WCM-BT-6
STANDARD FEATURES
g
Forced air evaporator blower system for maximum
efficiency in cooling - more consistent food product
temperature
g
Automatic Defrost System
g
Fully insulated for maximum efficiency and energy
savings
Factory applied gasket - makes installation a snap and
g
seals units to the counter top, thus eliminating
seepage
Accommodates standard 12” X 20” pans with the use
g
of separator channel(s), or fractional size pans with the
use of optional adapter bars
g
1-Year Parts & Labor Warranty
g
UL Recognized
ACCESSORIES
g
5YW - 5-Year Compressor Warranty
Stainless Steel adapter bars (pg DI-51-52)
g
Stainless Steel adapter plates (pg DI-51-52)
g
g
CP - Cover Plate with handles, S/S
g
RS - Remote on/off switch for counter mounting
RDVE - Rear Drain Valve Extension
g
* 220 Volt - 50 Cycle Compressor
g
ELECTRICAL: The unit will be wired for 15 amps., 120 volt,
single phase operation with an on/off thermostat switch and
pilot light. A 6' long, 3-wire cord and plug (NEMA 5-15P) will
be provided.
Specifications subject to change without notice.
*Please see Operation & Installation Manual for ALL
operation and maintenance details.
* Units with these accessories are not currently UL listed.
DI-27